Cross-Reference Lists
This chapter includes the following cross-reference lists:
-
Event Cross-Reference list
-
Command Cross-Reference list
-
Script Cross-Reference list
-
Message Cross-Reference list
Event Cross-Reference List
Table 162 Event Cross Reference List
Event |
Table |
---|---|
CHKDEVS |
SHUTSYS |
CHKINIT |
SHUTSYS |
CHKSTCS |
SHUTSYS |
CICSP1JC |
CICS |
DB2DOWN |
DB2 |
DB2UP |
DB2 |
DEVTYPES |
DEVICES |
INITFRST |
INITJES2 |
JES2GLBL |
INITSLV2 |
JOBOWNER |
TESTJOB2 |
NEWCTO |
SHUTSYS |
ORDERALL |
STARTSYS |
RESDB2 |
DB2 |
RESDUMP |
DUMPDS |
RESLOGRC |
LOGREC |
RESSMF |
SMF |
RMTINIT |
CTORMT |
SCTD |
STARTSYS |
SCTM |
STARTSYS |
SCTO |
STARTSYS |
SHUTCICS |
SHUTSYS |
SHUTCTD |
SHUTSYS |
SHUTCTM |
SHUTSYS |
SHUTDEVS |
SHUTSYS |
SHUTTSO |
SHUTSYS |
SHUTVTAM |
SHUTSYS |
STOPEXCP |
OMEGAMON |
STRTEXCP |
OMEGAMON |
SVTAM |
STARTSYS |
Command Cross-Reference List
The following is a list of commands defined in Control-O SolveWare solutions, the SolveWare table in which each command appears.
Table 163 Command Cross Reference List
Command |
Table |
---|---|
$TI* |
INITJES2 |
BRODCAST |
TSO |
CTO* |
DEVICES3 |
CTORMT |
CTORMT |
CTOREQ |
DEVICES3 |
GETNTVAR |
NETVIEW |
IMSCMD-* |
IMS |
NCCFCMD |
NETVIEW |
S CICS |
CICS |
S IDMS |
IDMS |
S IMS |
IMS |
S MPMxx |
ADABAS |
S NETVIEW |
NETVIEW |
S NETVSSI |
NETVIEW |
SETGLVAR |
NETVIEW |
SETNTVAR |
NETVIEW |
SHUTSYS |
SHUTSYS |
STOPNET |
NETVIEW |
STRTNET |
NETVIEW |
Script Cross-Reference List
The following is a list of scripts defined in Control-O SolveWare solutions.
Table 164 Script Cross Reference List
Script |
---|
BRODCAST |
CTOFTPPT |
GENALRT |
GETNVAR |
LOGNET |
NCCFCMD |
OMLEXSY |
OMLOC |
SETNVAR |
Message Cross-Reference List
The following is a list of Messages defined in Control-O SolveWare solutions, the SolveWare table in which each message appears.
Table 165 Message Cross Reference List
Message |
Table |
---|---|
$HASP085 |
SHUTSYS |
$HASP099 |
SHUTSYS |
$HASP100 |
SUPJES2 |
$HASP101 |
SUPJES2 |
$HASP110 |
SUPJES2 |
$HASP111 |
SUPJES2 |
$HASP112 |
SUPJES2 |
$HASP113 |
SUPJES2 |
$HASP114 |
SUPJES2 |
$HASP115 |
SUPJES2 |
$HASP116 |
SUPJES2 |
$HASP117 |
SUPJES2 |
$HASP118 |
SUPJES2 |
$HASP125 |
SUPJES2 |
$HASP150 |
SUPJES2 |
$HASP160 |
SUPJES2 |
$HASP250 |
SUPJES2 |
$HASP301 |
SUPJES2 |
$HASP309 |
SUPJES2 |
$HASP310 |
CICS |
$HASP310 |
IMS |
$HASP373 |
INITJES2 |
$HASP373 |
INITJES2 |
$HASP395 |
INITJES2 |
$HASP395 |
STARTSYS |
$HASP395 |
INITJES2 |
$HASP426 |
STARTSYS |
$HASP523 |
SUPJES2 |
$HASP524 |
SUPJES2 |
$HASP532 |
SUPJES2 |
$HASP533 |
SUPJES2 |
$HASP534 |
SUPJES2 |
$HASP540 |
SUPJES2 |
ADAN01 |
ADABAS |
ADAN21 |
ADABAS |
ADAN51 |
ADABAS |
ARC0100I |
SUPSYS |
ARC0200I |
SUPSYS |
ARC0208I |
SUPSYS |
ARC0503I |
SUPSYS |
ARC0728I |
SUPSYS |
ARC0734I |
SUPSYS |
BNJ030I |
NETVIEW |
CNM541I |
NETVIEW |
CNM580I |
NETVIEW |
CTM282I |
TSO |
CTO147I |
INITSLV |
DFH1588 |
CICS |
DFH1701 |
CICS |
DFH1799 |
CICS |
DFH4583 |
CICS |
DFHJC4583 |
CICS |
DFHKE1799 |
CICS |
DFHSI1517 |
CICS |
DFHSI1588D |
CICS |
DFHTM1701 |
CICS |
DFHTM1703 |
CICS |
DFHTM1715 |
CICS |
DFS3257I |
IMS |
DFS994I |
IMS |
DFS996I |
IMS |
DSI112I |
NETVIEW |
DSI802I |
NETVIEW |
DSI803I |
NETVIEW |
DSN3100I |
DB2 |
DSN3104I |
DB2 |
DSN3106I |
DB2 |
DSN9022I |
DB2 |
DSNC011I |
DB2 |
DSNU086I |
DB2 |
IAT2000 |
SUPJES3 |
IAT2006 |
SUPJES3 |
IAT5200 |
SUPJES3 |
IAT6101 |
SUPJES3 |
IAT6108 |
SUPJES3 |
IAT6118 |
SUPJES3 |
IAT7001 |
SUPJES3 |
IAT7007 |
SUPJES3 |
IAT7120 |
SUPJES3 |
IAT7450 |
SUPJES3 |
IAT9123 |
SUPJES3 |
IAT9124 |
SUPJES3 |
IAT9127 |
SUPJES3 |
IAT9190 |
SUPJES3 |
IAT9191 |
SUPJES3 |
ICH408I |
SUPSYS |
IDMS DC013 |
IDMS |
IDMS DC050 |
IDMS |
IDMS DC201 |
IDMS |
IDMS DC205 |
IDMS |
IEA405E |
CONSOLE |
IEA848I |
SUPMVS |
IEA911E |
DUMPDS |
IEA989I |
SUPMVS |
IEA994A |
DUMPDS |
IEA994E |
DUMPDS |
IEA995I |
SUPMVS |
IEC070I |
SUPMVS |
IEC130I |
SUPMVS |
IEC141I |
SUPMVS |
IEC161I |
SUPMVS |
IEC331I |
SUPMVS |
IEC501A |
DEVICES |
IEC501E |
DEVICES |
IEC502E |
DEVICES |
IEC705I |
SUPMVS |
IEC999I |
SUPMVS |
IEE043I |
SUPMVS |
IEE302I |
DEVICES |
IEE361I |
SMF |
IEE362A |
SMF |
IEE363I |
SMF |
IEE364I |
SMF |
IEE365I |
SMF |
IEE366I |
SMF |
IEE400I |
SUPMVS |
IEE711I |
DUMPDS |
IEE794I |
DEVICES |
IEF097I |
SUPMVS |
IEF125I |
SUPMVS |
IEF126I |
SUPMVS |
IEF170I |
SUPMVS |
IEF188I |
SUPMVS |
IEF196I |
SUPMVS |
IEF202I |
SUPMVS |
IEF233A |
DEVICES |
IEF233D |
DEVICES |
IEF234E |
DEVICES |
IEF236I |
SUPMVS |
IEF237I |
SUPMVS |
IEF238D |
DEVICES |
IEF238D |
DEVICES2 |
IEF281I |
DEVICES |
IEF287E |
DEVICES |
IEF287I |
SUPMVS |
IEF288I |
SUPMVS |
IEF290E |
DEVICES3 |
IEF403I |
SUPMVS |
IEF403I |
ADABAS |
IEF403I |
CICS |
IEF403I |
IDMS |
IEF403I |
IMS |
IEF403I |
NETVIEW |
IEF404I |
SUPMVS |
IEF404I |
ADABAS |
IEF404I |
CICS |
IEF404I |
IDMS |
IEF404I |
IMS |
IEF404I |
NETVIEW |
IEF404I |
SHUTSYS |
IEF450I |
NETVIEW |
IEF450I |
TESTJOB1 |
IEF450I |
TESTJOB2 |
IEF452I |
SUPMVS |
IEF452I |
TESTJOB1 |
IEF452I |
TESTJOB2 |
IEF453I |
TESTJOB1 |
IEF453I |
TESTJOB2 |
IEF453I |
SUPMVS |
IEF677I |
SUPMVS |
IEF722I |
SUPMVS |
IEF863I |
OMEGAMON |
IEF877E |
DEVICES |
IFB030I |
LOGREC |
IFB040I |
LOGREC |
IFB050I |
LOGREC |
IFB060E |
LOGREC |
IFB070I |
LOGREC |
IFB080E |
LOGREC |
IFB081I |
LOGREC |
IFB082I |
LOGREC |
IFB083I |
LOGREC |
IFB084I |
LOGREC |
IGF502E |
DEVICES |
IKJ144I |
SUPSYS |
IKJ572I |
SUPSYS |
IKJ605I |
SUPSYS |
IKJ606I |
SUPSYS |
IKT010D |
SHUTSYS |
IKT012D |
SHUTSYS |
IKT100I |
SUPSYS |
IKT108I |
SUPSYS |
IST093I |
STARTSYS |
IST234I |
SUPSYS |
IST259I |
SUPSYS |
IST530I |
SUPSYS |
IST532I |
SUPSYS |