Previous Topic

Next Topic

Book Contents

Book Index

Monitor parameters section

The following parameters relate to the online monitors you are defining. If required, you can specify several monitor definitions.

Table 32 Monitor parameters

Parameter

Description

MONITOR (NAME)

Name or mask of the Online monitor.

Max.Ses. (MAXSESS)

The maximum number of users that can work concurrently under each IOA Online monitor address space.

  • Default: 10

Note: The value specified for this parameter may be influenced by the storage requirements for various groups of users. For example, an IOA Online monitor accepting Control‑D Online viewing users, using tranid DOLV, may be limited to a maximum of approximately 50 users. If Control-V is installed, this maximum should be decreased to 25. An IOA Online monitor accepting users who use all the options of all INCONTROL products may be limited to a much smaller number of users (usually not more than 10).

Transactions (TRANS)

List of transaction ID names or masks.

  • Default: IALL

Timeout (MTOUT)

Specific timeout for this monitor.

  • Mandatory

If you enter 0 or leave this parameter blank, the session timeout will be used.

Note: All parameters mentioned above and in Global parameters section reside in the IOAXPRM member in the IOA.PARM library.

Parent Topic

Step 10.1 – Set IOA online monitor parameters