The init_prflag utility resets the sleep times and trace levels for Control-M/Server processes, as follows:
-
Resets the sleep times for all Control-M/Server processes to their initial (installation) values, as described in init_prflag Sleep Time Considerations.
-
Resets the trace level for all Control-M/Server processes to zero.
The sleep time setting for Control-M/Server processes can affect the functionality of Control-M/Server and your data center performance. Sleep time is the length of time that a process lies dormant before it wakes up to determine if any request to perform an action was received. When you modify certain Control-M/Server process sleep time settings, it is important to consider the number of jobs that are processing, the job schedule plan, and the overall load on the host.
Running the init_prflag Utility
This procedure describes how to run the init_prflag utility, which enables you to reset sleep times and trace levels for Control-M/Server processes.
Begin
-
Shut down Control-M/Server.
-
From a command prompt, run the following command:
init_prflag
init_prflag Sleep Time Considerations
The following table describes the sleep time considerations for the init_prflag utility.
Process |
Task |
Sleep Time Initial Settings |
Sleep Time Modification Considerations |
---|---|---|---|
SU |
Supervisor |
60 |
Increase: Delay in startup, downloads, and New Day A Control-M process that begins every day at 7:00 AM, adds jobs and folders to the Run Queue for the day that is about to begin, and removes jobs and folders from previous days. procedure. |
RT |
Inter-process Communication Router |
30 |
No effect. |
WD |
Watchdog |
360 |
No effect. |
SL |
Job Selector and Job Post-processing |
5 |
Increase: Delay in job submission and notifications for late submission. This can be increased during period of minimal job processing. |
TR |
Job Tracking |
5 |
Increase: Delay in freeing resources after job ends and delay in notifications. Can be increased during period of minimal job processing. |
NS |
Communication with Control-M |
30 |
No effect. |
LG |
Utilities Agent Invoker |
360 |
No effect. |
CO |
Communication Agents |
60 |
No effect. |
CD |
|
60 |
No effect. |
CS |
|
N/A |
No effect. |
CA |
|
N/A |