Additional Settings

In the Conversion Tools, you must set the specific Additional Settings for each scheduler, as follows:

Broadcom Appworx Additional Conversion Settings

The following table lists the Appworx Additional Conversion Settings:

Conversion Settings

Description

Node Default Platform

Defines the name of the default operating system for each node data.

First Day of the Week

Defines the first day of the week of your Control-M work environment.

Keep Active for

Defines the maximum number of days that a Control-M job can wait for execution after run date (default: 0). Valid values: 0-99 (integer).

Don't Convert AppWorx disabled events

Defines that disabled events in the AppWorx data is not converted to Control-M data.

Convert Appworx entities that don't reside under Process Flow

Defines that entities not under Process Flow in the Appworx data are converted to Control-M data.

CID<Unique number>@JOBA@JOBB

Determines how two jobs are connected by creating a unique event in the format: CID<Unique number>@JOBA@JOBB.

Delete Events

Determines to delete the event after the next job has finished running

JOBA@<Status>

Determines a dependence event between many jobs according to its end status.

For more details see Events.

Broadcom Automic UC4 Additional Conversion Settings

The following table lists the Automic UC4 Additional Conversion Settings and UC4 Scripts Conversion Settings:

Conversion Settings

Description

General

Convert UC4 executable objects without scheduling reference

Converts objects that are not in any UC4 Schedule definitions, such as Post Script.

For more information about converting UC4 jobs with Post Script, see Converting UC4 Scripts to Control-M.

First day of the week

Defines the first day of the week to your Control-M work environment.

Default UC4 Client Time Zone

Defines the time zone of the UC4 client server.

Convert 'Start' and 'End' tasks to Dummy jobs

Converts Start and End tasks to Control-M Dummy jobs. By default, Start and End tasks are ignored and not added to Control-M.

Set 'Adjust Event' to 'Y' in all folders to replace jobs that are not scheduled with Dummy jobs

Determines to replace unscheduled jobs with Dummy jobs by seting Adjust Event to Y in all folders.

Job/Folder Name Manipulation

Change prefix/suffix

Determines whether to use a character to indicate the location in the filename where characters were removed.

Truncate characters from the Beginning

Shortens a filename by truncating characters from the beginning of the name.

Truncate characters from the end

Shortens a filename by truncating characters from the end of the name.

Uniqueness Suffix Separator

Determines whether to use a character to separate the original filename from the numbers that are added to the end of the filename.

Event Name Convention

Delimiter

Determines which character is used to separate the prefix, suffix, or events.

Prefix

Determines the prefix used to separate the events.

Suffix

Determines the suffix used to separate the events.

Format

Defines the default format used for creating job dependencies.

Event name format that will be created

Displays the resulting format based on the changes made to the other options in the Event Name Convention area.

UC4 Scripts Conversion

Describes how to use UC4 scripts in Control-M.

For more information, see Converting UC4 Scripts to Control-M.

Additional Conversion Options

Don't add Pre scripts into Control-M embedded script

Determines whether to convert the Pre script content into the Control-M Embedded Script field.

A warning message about Pre Script content still appears in the Conversion Report.

By default, the Conversion Tool converts the content of UC4 pre script into the Control-M embedded script field.

If you do not want to convert UC4 Pre-Script and remove the warning message, set the appropriate rule in the UC4_scripts_conversion_to_ctm.xls file.

Don't add Post scripts into Control-M embedded script

Determines whether to convert Post script content into the Control-M embedded script field.

A warning message about post script content still appears in the Conversion Report.

By default, the Conversion Tool converts the content of UC4 Post Script into the Control-M Embedded script field.

If you do not want to convert UC4 pre script and remove the warning message, set the appropriate rule in the UC4_scripts_conversion_to_ctm.xls file.

Convert UC4 scripts with '1' command into Control-M command line jobs

Determines whether to convert UC4 scripts, that contain only one command into Control-M OS Command jobs, if it they do not include UC4 scripting language keywords.

By default, the Conversion Tool converts the content of UC4 Scripts into the Control-M embedded script fields.

Converting UC4 Scripts to Control-M

This procedure describes how to convert UC4 scripts to Control-M compatible scripts. Broadcom Automic (UC4) uses its own scripting language, so you need to define how the Conversion Tool how to convert the scripts.

Before you begin

Ensure that you have successfully progressed through the Conversion Tool until you reach the UC4 Scripts Rule tab of the Conversion Settings window. For more information, see Converting to Control-M.

Begin

  1. From the UC4 Scripts Rule tab, open the following file:

    UC4_scripts_conversion_to_ctm.xlsx

    This file contains the Conversion Tool automatic analysis of the UC4 scripts.

  2. In the UC4_scripts_analysis tab, review the analysis to determine the optimal way to convert the scripts:

    • UC4 Script Pattern: Displays the UC4 script patterns found in the scripts.

    • UNC Script Content: Displays each script pattern instance when a script pattern+ is selected.

    • Number of UC4 Jobs use the Script Pattern: Displays the number of jobs that contain the script pattern.

  3. In the UC4_scripts_conversion_to_ctm tab, fill in the Select conversion option 1 or select conversion option 2 columns. For column descriptions , see UC4_scripts_conversion_to_ctm Tab.

    In the Select conversion option 1 or Select conversion option 2 columns do any of the following:

  4. Save the UC4 Scripts Conversion file, copy it, and move it to the directory where you loaded the files that you extracted from the Automic UC4 scheduler.

  5. Re-open the Conversion Tool and run the conversion.

    The Conversion Tool uses the conversion rules in the file to convert the UC4 scripts to Control-M compatible scripts.

UC4_scripts_conversion_to_ctm Tab

The following table describes the information contained in the UC4_scripts_conversion_to_ctm tab in the UC4_scripts_conversion_to_ctm .xls file:

Name

Description

UC4 Script type

Indicates if the UC4 Script found belongs to the Pre/Post Script attributes.

In the Select conversion option column the options vary according to Script Type.

UC4 Script Content

Contains the UC4 script detected in the Pre/Post-Script attribute.

Number of jobs use the script

Contains the number of UC4 Jobs that use the same script.

Type

Indicates the type of Control-M job to use when creating Control-M If Actions or Parameters data in Control-M client.

Select conversion option 1

Enables you to define how to convert UC4 Pre/Post Scripts into Control-M using one of the following options:

  • Convert to Control-M If Actions (Post Script Type only)
  • Convert to Control-M Variables (Pre Script Type only)
  • Replace with another Script (Pre Script Type only)
  • Don't Convert Script

For more information about the Control-M options, see Control-M Options.

Conversion option 1 value

Defines the Conversion option value that is imported into Control-M

Select conversion option 2 (optional)

Defines an additional option in Control-M, as described in Select conversion option 1 in this table.

Conversion option 2 value (optional)

Defines an additional Conversion option value, as described in Conversion option value 1 in this table.

Control-M Options

The following table describes the Control-M options in the Select Conversion option column in the UC4 Script Conversion file.

Script Type

Control-M Option

Description

Post Script

Convert to Control-M If Actions

Converts UC4 Post Script to Control-M If Action.

You must supply the Control-M If Action XML in the Conversion Option Value column, as described in Adding an If Action XML Value.

Post Script

Do not Convert Script

Does not convert UC4 Post Script to a Control-M embedded Script job and the Conversion Tool does not issue a warning message in the Conversion Report.

Use this option if you decide that UC4 Script is not required in Control-M.

Pre Script

Convert to Control-M Variables

Converts UC4 Pre Script to a Control-M variable.

You must supply the Control-M Variable XML in the Conversion Option Value column, as described in Adding a Control-M Variable XML Value.

Pre Script

Replace with another Script

Replaces a UC4 Pre Script with another script that does not use UC4 Scripting language.

You must supply a replacement script in the Conversion Option Value column.

Pre Script

Do not Convert Script

Does not convert UC4 Pre script to a Control-M embedded Script job and does not issue a warning message in the conversion report.

Use this option if you decide that UC4 Script is not required in Control-M.

Adding an If Action XML Value

This procedure describes how to add an If Action XML to the Conversion option value column in the UC4 Script Conversion file.

Begin

  1. From the Control-M Planning domain, create a job.

  2. Create an If Action, by adding the If Action parameters, as necessary, {as described in If Actions in Control-M Parameters.

  3. Export the selected jobs to an XML file, by doing one of the following:

    • Select the entities to export.

    • Select Export, and select Export Selected Entities.

    • To export the workspace, click Export.

  4. Click Save.

  5. Open the XML file that you saved in step 4, and copy and paste the If Action into the Conversion option value 1 and/or 2 columns in the UC4 Script file.

    Copy only the relevant part of the XML as in the following example:

    Exported XML:

    <?xml version="1.0" encoding="utf-8"?>

    <!--Exported at 18-09-2017 15:35:47-->

    <DEFTABLE xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:noNamespaceSchemaLocation="Folder.xsd">

    <FOLDER DATACENTER="CTM-Server1" VERSION="900" PLATFORM="UNIX" FOLDER_NAME="Folder#2" FOLDER_ORDER_METHOD="SYSTEM" TYPE="1" ENFORCE_VALIDATION="N">

    <JOB MEMNAME="a" JOBNAME="OS_Job#1" CREATED_BY="amir" RUN_AS="a" CRITICAL="0" TASKTYPE="Job" CYCLIC="0" INTERVAL="00001M" MEMLIB="a" CONFIRM="0" RETRO="0" MAXWAIT="0" MAXRERUN="0" AUTOARCH="1" MAXDAYS="0" MAXRUNS="0" DAYS="ALL" JAN="1" FEB="1" MAR="1" APR="1" MAY="1" JUN="1" JUL="1" AUG="1" SEP="1" OCT="1" NOV="1" DEC="1" DAYS_AND_OR="O" SHIFT="Ignore Job" SHIFTNUM="+00" SYSDB="1" IND_CYCLIC="S" RULE_BASED_CALENDAR_RELATIONSHIP="O" APPL_TYPE="OS" MULTY_AGENT="N" USE_INSTREAM_JCL="N" CYCLIC_TOLERANCE="0" CYCLIC_TYPE="C" PARENT_FOLDER="Folder#2">

    <ON STMT="*" CODE="NOTOK">

    <DOACTION ACTION="OK" />

    <DOMAIL URGENCY="R" DEST="[email protected]" SUBJECT="Job Failed" ATTACH_SYSOUT="D" />

    </ON>

    </JOB>

    </FOLDER>

    </DEFTABLE>

     

    Relevant XML:

    <ON STMT="*" CODE="NOTOK">

    <DOACTION ACTION="OK" />

    <DOMAIL URGENCY="R" DEST="[email protected]" SUBJECT="Job Failed" ATTACH_SYSOUT="D" />

    </ON>

Adding a Control-M Variable XML Value

This procedure describes how to add a Control-M Variable XML to the Conversion option value column in the UC4 Script Conversion file.

Begin

  1. In Control-M client, from the Planning domain, create a job.

  2. Create the Control-M Variable, by adding the variables as necessary, as described in Variables in Control-M Parameters.

  3. Export the selected jobs to an XML file, by doing one of the following:

    • Select the entities to export.

    • Select Export, and select Export Selected Entities.

    • To export the workspace, click Export.

  4. Click Save.

  5. Open the XML file that you saved in step 4, and copy and paste the Control-M Variable XML into the Conversion option value 1 and/or 2 columns in the UC4 Script Conversion file.

    Copy only take the relevant part of the XML as in the following example:

    Exported XML:

    <?xml version="1.0" encoding="utf-8"?>

    <!--Exported at 18-09-2017 15:35:47-->

    <DEFTABLE xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:noNamespaceSchemaLocation="Folder.xsd">

    <FOLDER DATACENTER="CTM-Server1" VERSION="900" PLATFORM="UNIX" FOLDER_NAME="Folder#2" FOLDER_ORDER_METHOD="SYSTEM" TYPE="1" ENFORCE_VALIDATION="N">

    <JOB MEMNAME="a" JOBNAME="OS_Job#1" CREATED_BY="amir" RUN_AS="a" CRITICAL="0" TASKTYPE="Job" CYCLIC="0" INTERVAL="00001M" MEMLIB="a" CONFIRM="0" RETRO="0" MAXWAIT="0" MAXRERUN="0" AUTOARCH="1" MAXDAYS="0" MAXRUNS="0" DAYS="ALL" JAN="1" FEB="1" MAR="1" APR="1" MAY="1" JUN="1" JUL="1" AUG="1" SEP="1" OCT="1" NOV="1" DEC="1" DAYS_AND_OR="O" SHIFT="Ignore Job" SHIFTNUM="+00" SYSDB="1" IND_CYCLIC="S" RULE_BASED_CALENDAR_RELATIONSHIP="O" APPL_TYPE="OS" MULTY_AGENT="N" USE_INSTREAM_JCL="N" CYCLIC_TOLERANCE="0" CYCLIC_TYPE="C" PARENT_FOLDER="Folder#2">

    <VARIABLE NAME="%%A" VALUE="Local" />

    <VARIABLE NAME="%%\\Banai\Amir" VALUE="Pool" />

    <VARIABLE NAME="%%\BB" VALUE="Global" />

    </JOB>

    </FOLDER>

    </DEFTABLE>

     

    Relevant XML:

    <VARIABLE NAME="%%A" VALUE="Local" />

    <VARIABLE NAME="%%\\Banai\Amir" VALUE="Pool" />

    <VARIABLE NAME="%%\BB" VALUE="Global" />

Broadcom AutoSys Additional Conversion Settings

The following table lists the AutoSys Additional Conversion Settings tab:

Conversion Settings

Description

General
Source Command

Defines the command used to source the script defined in the profile field of your source scheduler.

Convert unscheduled boxes to Run Method="ON_DEMAND"

Determines to convert unscheduled boxes to the USERDAILY="ON_DEMAND" checkbox.

By default, Control-M runs the jobs automatically. This option enables to run the jobs on demand.

Event

Event pattern that will be created.

Determines the event format.

Remove job's events after job's completion

Determines to remove the job's events after the job has completed.

File Watcher Type

MFT

Determines to convert File Watcher jobs to MFT jobs.

Ctmfw utility

Determines to use the Control-M File Watcher utility (and not MFT).

SAP

Determines to convert SAP jobs using the Control-M SAP forms.

PeopleSoft

Determines to convert SAP jobs using the Control-M PeopleSoft forms.

Text File Reading and Monitoring Job Type

Converts Autosys Text File Reading and Monitoring jobs to Control-M FWText jobs.

The Control-M FWText job supports the following fields:

  • text_file_filter

  • text_file_name

  • text_file_filter_exists

The following fields are permanently set as follows:

  • monitor_mode: NOW

  • text_file_mode: LINE

Related links:

Broadcom JOBTRAC Additional Conversion Settings

The following table lists the Broadcom JOBRTAC Rules Additional Conversion parameters:

Parameter

Description

Convert DS jobs

Defines the Distributed Systems (DS) job when you select the Convert DS jobs checkbox.

Events

Determines dependencies between jobs.

Start Day of the Week

Determines the start day of the week for scheduling.

New Day time

Determines the value in the New Day time value specified in CTMPARM field.

Customize Control-M jobname

Defines the Alternate JCL member name as the jobname

SCL libraries processing

Enables you to process each SCL library separately.

The following table lists the Broadcom JOBRTAC Rules Additional Conversion parameters in the Mainframe Editor:

Parameter

Description

SCHED TAB – Scheduling Table Library

Defines the Control-M scheduling table that stores job definitions.

Default: CTM.SCHEDULE

OVERLIB – JCL Over Lib

Defines the value as OVERLIB for converted jobs.

Default: CTM.OVERLIB

You must verify that the JCL Overlib Library is allocated in the Mainframe.

INCLIB – Control-M Include Library

Defines the value as INCLIB for converted jobs.

Default: CTM.INCLIB

JCLLIB – Alternate Memname

Defines the value of an additional Memname, which is used for saving converted jobs.

Default: CTM.JCLLIB

You can use the JCL Library for alternate members allocated during Control-M installation.

You must verify that the Control-M JCL Library for alternate members is allocated in the Mainframe.

CTODSN – Control-O rule library

Defines the Control-O rules library containing Dataset and messages triggering events for ADR, AMR and SCS.

Default: CTM.CTODSN.

IOAENV - Library full path

Defines the name of the IOA/Control-M production environment’s IOAENV library.

CMEM – CMEM rule library

Defines the CMEM rules library containing Job Arrival events for RESOURCE file conversion.

Default: CTM.CMEM.

You must verify that the CMEM rules library is allocated in the Mainframe.

Control-O run JCL library

Defines the JCL library name containing JCL files running from Control-O rules.

Default: CTM.CTO.JCL.

You can use the Control-O JCL library allocated during Control-O installation. You must verify that Control-O run JCL library is allocated in the Mainframe.

JOB CARD - Job card for output JCL

Enables you to use job cards for the output JCL that is created to run at the end of the conversion to return the converted data to the appropriate files.

Number of Directory Blocks

Defines the number of directory blocks allocated to the converted JCL library.

This should must be the same as the number of directory blocks in the original Jobtrac JCL library.

MAXCC

Defines the Maximum condition code for OK status.

Valid values: 0-4095 (integers).

Sysout From Class

Defines a blank space or single character to specify the Sysout class.

Sysout To Class

Defines a blank space or single character to specify the Sysout class. The Sysout is moved to the end of the job.

Default: ‘*’.

Sysout option

Defines the Sysout action when a job finishes.

Valid Values:

  • Release

  • Delete

  • None

Broadcom Dollar Universe Additional Conversion Settings

The following table lists the Dollar Universe Additional Conversion Settings:

Conversion Settings

Description

UPROCs with Task but Without a Session

Convert all UPROCS without a Session into a Single Control-M SaaS folder

Determines to convert all UPROCs that have a task but do not have a session into one Control-M folder containing all UPROCs.

This option is relevant only when the Convert UPROCs that do not have a session is selected.

Convert each UPROC without a Session into a Single Control-M SaaS folder

Determines to convert each UPROC that does not have a session into its own Control-M folder.

UPROCs without scheduling

Convert UPROCS without scheduling

Determines to convert UPROCS without scheduling to Control-M data.

Other Information

Date Format

Determines the format for date input and display

Area

Determines the Control-M folder name, built in the format:
<AREA>_<SESSION>_<MU>
from the following options:

  • EXP

  • SIM

  • INT

  • APP

Priority Conversion

Convert equal priorities

Determines to convert Dollar Universe jobs even when multiple jobs have the same priority value.

If all Dollar Universe jobs use the same value, this degrades the performance of Control-M. To avoid this effect, you can choose to not convert priorities according to the priority conversion option that you select.

Don't convert priorities if all equal

Determines to not convert Dollar Universe jobs when multiple jobs have the same priority value.

Irrespective of the option chosen, if not all priorities are equal, the priorities will be converted as usual.

HDP Options

Append events for viewing links between jobs in Control-M

Determines to append events that provide the ability to view the flow between jobs in the Planning and Monitoring domains in Control-M client.

Notify destination name for ctmorder script

Defines the name of the destination file in your environment which is necessary for adding a Notification destination in Control-M client.

Event

{Job/Folder Name}_Status

Determines the format of the event.

{Job/Folder Name}TO-TargetJob:Job/Folder Name}

Determines the format of the event.

Delete Events

Determines to delete the event after the next job has finished running.

Broadcom Unicenter WLM (TNG) Additional Conversion Settings

The following table lists the Unicenter WLM (TNG) Additional Conversion Settings:

Conversion Settings

Description

General

Date Format

Determines the WLM date format for your conversion project.

Applicability-Application Separator

Defines a separator character that converts WLM grouping to Control-M hierarchy format.

PROD#SET1 where the separator is #, the Control-M Application entity is set to PROD and the Sub-Application is set to SET1.

Resources

Determines the following target Control-M resource types:

  • Auto

  • Lock Resource

  • Resource Pool

If you select Auto it automatically selects a target Control-M resource type.

PRIOR handling

Determines the following events:

  • Prev: Sets the event to a previous scheduling date.

  • Dummy job: Creates the event the following day.

Event Date for Everyday Job

Determines the generated Control-M in or event dates for everyday jobs.

This setting is only available when PRIOR handling is set to Prev.

  • Any: Enables the subsequent job to be set with an event date, so the event is deleted when the job ends.

  • Prev: Enables the subsequent job to be set with an event date, so that the event is not deleted when the job ends. For both options, the predecessor job sets the event to Run Date.

Keep active for

Defines the maximum number of days a job can wait for execution after run date. Valid value: Integer between 1 and 99.

This parameter influences Control-M jobs only if the WLM job definition BACKLOG value is set to YES.

First Day of the Week

Determines the first day of the week of your work environment.

Event Name Convention

Delimiter

Defines the character to separate the prefix, suffix, or events.

Prefix

Defines the prefix to separate the events.

Suffix

Defines the suffix to separate the events.

Format

Determines the default format used for creating job dependencies.

The default format has 2 different conventions:

  • JOBA-TO-JOBB

  • JOBA-ENDED-<Status>

Event name format that will be created

Determines the resulting format based on the changes made to the other options in the Event Name Convention area.

Delete Events

Determines to delete the event after the next job has finished running. Jobs which trigger more than one job may cause some successor jobs not to be triggered.

Calendar

 

All Days Calendar Name

Defines the name of the calendar that runs every day.

Holidays Calendar Name

Defines the name of the holiday calendar.

Number of Year

Determines the number of years the calendars are used. This sets the range of dates for the Control-M calendars.

Trigger Jobs Conversion (DSCLOSEU)

Enable

Determines to activate the conversion of WLM trigger jobs. The Control-M File Watcher utility is used for the conversion of trigger jobs.

Interval

Determines the interval time in seconds between each file check. Valid value: An integer between 1 and 99.

Time Stop

Defines the stop time in the format, "hh:mm" to end file watching.

Station ID and Owner Table

Defines name of the station and person who has permissions to execute File Watcher jobs for each station.

You can use wildcards for both the Station ID and Owner fields: * for any word, and ? for any character.

Create File Watcher job per trigger

Determines to enable you to create a file watcher job per trigger. If you want to create a file watcher job per station leave the check box unchecked.

Parameter Configuration

Determines to enable the mapping of WLM parameters to Control-M parameters.

SAP

Determines to convert SAP jobs to Control-M.

Tandem

Determines to run TACL scripts as TACL jobs in Control-M.

Broadcom Workload Automation DE (dSeries) Additional Conversion Settings

The following table lists the Workload Automation DE Additional Conversion Settings:

Conversion Settings

Description

General

First Day of the Week

Determines the first day of the week of your Control-M work environment.

Notifications Urgency

Determines the urgency for converted job notifications. Select the urgency for notifications set by Control-M.

Events

JOBA-JTO-JOBB

Determines how two jobs are connected by creating a unique event in the format: JOBA_JOBB.

Cleanup Events

Determines to delete the event after the next job has finished running.

JOBA-ENDED-<Status>

Determines a dependence event between many jobs according its end status.

For more details, see Events.

Cron Additional Conversion Settings

The following table lists the Cron Additional Conversion Settings:

Conversion Settings

Description

General

First Day of the Week

Determines the first day of the week of your Control-M work environment.

Action:Mail Generation

Determines email job notification behavior:

  • Never

  • Only if $MAILTO was defined in crontab: Sends email notifications to the email address that is defined in the $MAILTO variable in crontab.

    If this option is selected, it overrides any email address that you may have entered in the default email address field.

  • For All Jobs: Sends email notifications to the email address that you enter. You can also enter variables as part of the email address.

    {User}@domain.com.

TWS Additional Conversion Settings

The following table lists the TWS Additional Conversion Settings:

Conversion Settings

Description

General

Keep active for

Determines the maximum number of days that a Control-M job can wait for execution after the run date.

Valid values: 0-99 (integer) Default: 1

The Keep active for parameter effects Control-M jobs only when the TWS parent container has the CARRYFORWARD attribute.

First Day of the Week

Determines the first day of the week of your Control-M work environment.

Date Format

Determines the format for date input and display.

Convert OPENS statement to File Watcher

Converts an OPENS Statement in TWS to Control-M File Watcher.

Standalone Jobs

Determines whether to group all standalone jobs in one folder, or to create a different folder for each standalone job

Calendar

Defines the default names for calendars of the following types:

  • Work days calendar

  • Free days calendar

  • All days calendar

Event

Event pattern that will be created

Determines the event syntax

Remove job's events after job's completion

Determines whether to remove events after job completion.

Scheduling Conversion

 

Use ExcludeRBCs

Enables the Conversion Tool to convert TWS EXCEPT statements using the Rule Based Calendars.

Do not convert "EXCEPT" statements

Determines that EXCEPT statements are not converted to Control-M (default). An Error message WRN6022 is issued for each statement that is not converted.

TWS ON statements are converted to Control-M Rule Based Calendars.

Convert "EXCEPT" statements to dummy jobs

Determines that a dummy job is created for each EXCEPT statement. The converted folder depends on the event(s) released by the dummy job(s).

TWS ON statements are converted to Control-M rule-based calendars.

Convert "ON" and "EXCEPT" statements to dummy jobs

Determines that a dummy job is created for any ON or EXCEPT statement. This dummy job derives scheduling definitions from the corresponding statement.

The converted folder depends on the events released by the dummy jobs, with an OR between events created from ON statements, and a logical AND between events created from EXCEPT statements.

In addition to the dummy jobs, ON statements are converted to Rule Based Calendars (otherwise the folders are not run).

SAP Editor - TWS

 

Job Count

-i = <account_name> SAP account name

User

-user = the SAP job owner

Job Class

-c = <class_name> SAP job class

Job Name

-job = <job_name> the SAP job name

PeopleSoft Editor

Settings in this tab are available after selecting the Enable PeopleSoft conversion checkbox. If unselected, PeopleSoft jobs are converted to regular OS jobs in Control-M.

Process name

Defines the process name to be scheduled.

Type

Defines the output destination type, specifying the file path, printer destination URL or email address.

Run Control

Defines the Run control attributes that are associated with a process or job.

Run Location

Defines the name of the server to be used for running the process or job.

OS400 Editor

Settings in this tab are available after selecting the Enable OS400 conversion checkbox. If unselected, OS/400 jobs are converted to regular OS jobs in Control-M.

Convert CALL commands to object type program

Enables the Conversion Tool to convert command line CALL <program> … to job type OS400 Program rather than OS/400 command line jobs.

For any TWS command line job that starts with the CALL command, the job type can be set to OS400 Program. The CALL command program name and the parameters are extracted from the command line into the appropriate job attributes.

Keyword for SUBMIT

Enables TWS to submit the job to batch, including the submit jobs attributes.

Keyword for DOCOMMAND

Enables TWS to run the command directly without submitting it to batch. There are no submit job attributes.

Control-M submits the job to batch. For SUBMIT mode, the submit job attributes are extracted from the SUBMIT string. For DOCOMMAND mode, the default submit job attributes are used.

JP1 Additional Conversion Settings

The following table lists the JP1 Additional Conversion Settings:

Conversion Settings

Description

Events

CID<Unique number>@JOBA-TO-JOBB

Determines how two jobs are connected by creating a unique event in the format: CID<Unique number>@JOBA@JOBB.

Select the Cleanup events checkbox to delete the event after the next job has finished running.

CID<Unique number>@JOBA-ENDED-<Status>

Determines the events between many jobs according to its end status.

For more details, see Events.

Task Scheduler Additional Conversion Settings

The following table lists the Task Scheduler Additional Conversion Settings:

Conversion Settings

Description

General

Ignore disabled tasks

Causes disabled tasks to be ignored during conversion.

Ignore disabled triggers

Causes disabled triggers to be ignored during conversion.

Job/Folder Name Manipulation

Change prefix/suffix

Determines the character used to indicate the location in the filename where characters were removed.

Select one of the following options to shorten a filename that is too long:

  • Truncate characters from the beginning

  • Truncate characters from the end

Uniqueness suffix separator

Determines the character used to separate the original filename from the numbers that are added to the end of the filename.

Tidal CPS Additional Conversion Settings

This procedure describes how to set additional Tidal Software Enterprise Scheduler (Tidal) rules.

Begin

  1. From the Conversion Tool, click the General tab area and select one of the following options:

    • Remove job's in conditions after job's completion: Removes each In Condition for every Control-M entity in the Control-M conditions, which prevents irrelevant jobs (instances) from running.

    • Do not convert Tidal disabled jobs (Inactive jobs): Ignores all disabled Tidal jobs, which are not converted to Control-M.

      If a Tidal job group is disabled, its children are ignored, regardless of whether they are disabled.

    • First day of the week: Defines the first day of the week of your Control-M environment.

  2. Click Next.

Tidal Variables Mapping

The following sections describe how the Conversion Tool converts Tidal time and date variables into Control-M, together with examples:

If a job is converted to a Control-M embedded script, ensure that the variable does not contain spaces in the format, otherwise it results in an error when Control-M tries to resolve the variable at runtime.

<JobStart.hh:mm AM/PM>

Tidal Time and Date Format Mapping

The following describes the Tidal time and date formats that are converted to Control-M variables.

Tidal format

Control-M Variable

d

%%NUMBER%%DD

dd

%%DD

ddd

Not supported

dddd

Not supported

j

%%SHORT_JULDAY

%%SHORT_JULDAY=%%JULDAY %%MINUS 0

jj

%%SHORT_JULDAY

%%SHORT_JULDAY=%%JULDAY %%MINUS 0

jjj

%%JULDAY

m

%%NUMBER%%MM

mm

%%MM

mmm

%%MMM%%MM

mmmm

%%MMMM%MM

yy

%%YY

yyyy

%%YYYY

fm

Not supported

fmm

Not supported

q

Not supported

fq

Not supported

fyy

Not supported

fyyy

Not supported

h

%%H%%HH

hh

%%HL%HH

H

%%NUMBER%%HH

HH

%%HH

AM/PM

%%AP%%HH

mm

%%MM as a substring of %%TIME

ss

%%SS

The following table lists the global time and date variables in Control-M.

Variable

Value

%%AP00 - %%AP11

AM

%%AP12 - %%AP23

PM

%%H00

12

%%H01-%%H12

1-12

%%H13 - %%H23

1-11

%%HL00

12

%%HL01-HL%%HL12

01-12

%%HL13-%%%HL23

01-11

%%MMM01

Jan

%%MMM02

Feb

%%MMM03

Mar

%%MMM04

Apr

%%MMM05

May

%%MMM06

Jun

%%MMM07

Jul

%%MMM08

Aug

%%MMM09

Sep

%%MMM10

Oct

%%MMM11

Nov

%%MMM12

Dec

%%MMMM01

January

%%MMMM02

February

%%MMMM03

March

%%MMMM04

April

%%MMMM05

May

%%MMMM06

June

%%MMMM07

July

%%MMMM08

August

%%MMMM09

September

%%MMMM10

October

%%MMMM11

November

%%MMMM12

December

%%NUMBER00

0

%%NUMBER01

1

%%NUMBER02

2

%%NUMBER03

3

%%NUMBER04

4

%%NUMBER05

5

%%NUMBER06

6

%%NUMBER07

7

%%NUMBER08

8

%%NUMBER09

9

%%NUMBER10

10

%%NUMBER11

11

%%NUMBER12

12

%%NUMBER13

13

%%NUMBER14

14

%%NUMBER15

15

%%NUMBER16

16

%%NUMBER17

17

%%NUMBER18

18

%%NUMBER19

19

%%NUMBER20

20

%%NUMBER21

21

%%NUMBER22

22

%%NUMBER23

23

%%NUMBER24

24

%%NUMBER26

25

%%NUMBER26

26

%%NUMBER27

27

%%NUMBER28

28

%%NUMBER29

29

%%NUMBER30

30

%%NUMBER31

31

Variable Resolution Examples

The following examples describe the date and time system variables, date variables with offset and Julian dates.

System variable - time (simple)

Tidal variable: <SysTime.HH:mm:ss>

Converts to the following:

<VARIABLE NAME="%%RESULT_HH_mm_ss_SysTime" VALUE="%%TIME" />

<VARIABLE NAME="%%HH_HH_mm_ss_SysTime" VALUE="%%SUBSTR %%RESULT_HH_mm_ss_SysTime 1 2" />

<VARIABLE NAME="%%MM_HH_mm_ss_SysTime" VALUE="%%SUBSTR %%RESULT_HH_mm_ss_SysTime 3 2" />

<VARIABLE NAME="%%SS_HH_mm_ss_SysTime" VALUE="%%SUBSTR %%RESULT_HH_mm_ss_SysTime 5 2" />

<VARIABLE NAME="%%HH_mm_ss_SysTime" VALUE="%%HH_HH_mm_ss_SysTime.:%%MM_HH_mm_ss_SysTime.:%%SS_HH_mm_ss_SysTime." />

If %%TIME = 141502 then:

%%HH_HH_mm_ss_SysTime = 14

%%MM_HH_mm_ss_SysTime = 15

%%SS_HH_mm_ss_SysTime = 02

Then %%HH_mm_ss_SysTime = %%HH_HH_mm_ss_SysTime.:%%MM_HH_mm_ss_SysTime.:%%SS_HH_mm_ss_SysTime.= 14:15:02

The dot (‘.’) is a concatenation operator that concatenates a variable with some other string.

So %%VariableName.STRING will be resolved to VariableValueSTRING

If there is no string after the concatenation operator, it is removed so %%VariableName. will be resolved to VariableValue.

System variable - date (simple)

Tidal variable: <SysDate.mmddyy>

Converts to:

<VARIABLE NAME="%%RESULT_mmddyy_SysDate" VALUE="%%$DATE" />

<VARIABLE NAME="%%YYYY_mmddyy_SysDate" VALUE="%%SUBSTR %%RESULT_mmddyy_SysDate 1 4" />

<VARIABLE NAME="%%YY_mmddyy_SysDate" VALUE="%%SUBSTR %%RESULT_mmddyy_SysDate 3 2" />

<VARIABLE NAME="%%MM_mmddyy_SysDate" VALUE="%%SUBSTR %%RESULT_mmddyy_SysDate 5 2" />

<VARIABLE NAME="%%DD_mmddyy_SysDate" VALUE="%%SUBSTR %%RESULT_mmddyy_SysDate 7 2" />

<VARIABLE NAME="%%mmddyy_SysDate" VALUE="%%MM_mmddyy_SysDate.%%DD_mmddyy_SysDate.%%YY_mmddyy_SysDate." />

When %%$DATE = 20150506

  1. Local variables are resolved to:

    %%YYYY_mmddyy_SysDate = 2015

    %%YY_mmddyy_SysDate = 15

    %%MM_mmddyy_SysDate = 05

    %%DD_mmddyy_SysDate = 06

  2. Then %%mmddyy_SysDate => %%MM_mmddyy_SysDate.%%DD_mmddyy_SysDate.%%YY_mmddyy_SysDate.

    %%MM_mmddyy_SysDate.%%DD_mmddyy_SysDate.%%YY_mmddyy_SysDate. => %%MM_mmddyy_SysDate.%%DD_mmddyy_SysDate.15

    %%MM_mmddyy_SysDate.%%DD_mmddyy_SysDate.15 => %%MM_mmddyy_SysDate.0615

    %%MM_mmddyy_SysDate.0615 => 050615

System variable - time (advanced)

Tidal variable: <SysTime.HmmAM/PM>

Converts to:

<VARIABLE NAME="%%RESULT_HmmAM_PM_SysTime" VALUE="%%TIME" />

<VARIABLE NAME="%%HH_HmmAM_PM_SysTime" VALUE="%%SUBSTR %%RESULT_HmmAM_PM_SysTime 1 2" />

<VARIABLE NAME="%%MM_HmmAM_PM_SysTime" VALUE="%%SUBSTR %%RESULT_HmmAM_PM_SysTime 3 2" />

<VARIABLE NAME="%%SS_HmmAM_PM_SysTime" VALUE="%%SUBSTR %%RESULT_HmmAM_PM_SysTime 5 2" />

<VARIABLE NAME="%%HmmAM_PM_SysTime" VALUE="%%NUMBER%%HH_HmmAM_PM_SysTime..%%MM_HmmAM_PM_SysTime.%%AP%%HH_HmmAM_PM_SysTime.." />

When %%TIME = 011703

  1. Local variable is resolved to:

    %%HH_HmmAM_PM_SysTime = 01

    %%MM_HmmAM_PM_SysTime = 17

    %%SS_HmmAM_PM_SysTime = 03

  2. %%HmmAM_PM_SysTime => Resolving happens from right to left

    %%NUMBER%%HH_HmmAM_PM_SysTime..%%MM_HmmAM_PM_SysTime.%%AP%%HH_HmmAM_PM_SysTime.. => %%NUMBER%%HH_HmmAM_PM_SysTime..%%MM_HmmAM_PM_SysTime.%%AP01.

    %%NUMBER%%HH_HmmAM_PM_SysTime..%%MM_HmmAM_PM_SysTime.%%AP01. => %%NUMBER%%HH_HmmAM_PM_SysTime..%%MM_HmmAM_PM_SysTime.AM

    %%NUMBER%%HH_HmmAM_PM_SysTime..%%MM_HmmAM_PM_SysTime.AM => %%NUMBER%%HH_HmmAM_PM_SysTime..17AM

    %%NUMBER%%HH_HmmAM_PM_SysTime..17AM => %%NUMBER01.17AM

    %%NUMBER01.17AM => 117AM

System variable - date (advanced)

Tidal variable: <SysDate.mmmm/d/yyyy>

Converts to:

<VARIABLE NAME="%%RESULT_mmmm_d_yyyy_SysDate" VALUE="%%$DATE" />

<VARIABLE NAME="%%YYYY_mmmm_d_yyyy_SysDate" VALUE="%%SUBSTR %%RESULT_mmmm_d_yyyy_SysDate 1 4" />

<VARIABLE NAME="%%YY_mmmm_d_yyyy_SysDate" VALUE="%%SUBSTR %%RESULT_mmmm_d_yyyy_SysDate 3 2" />

<VARIABLE NAME="%%MM_mmmm_d_yyyy_SysDate" VALUE="%%SUBSTR %%RESULT_mmmm_d_yyyy_SysDate 5 2" />

<VARIABLE NAME="%%DD_mmmm_d_yyyy_SysDate" VALUE="%%SUBSTR %%RESULT_mmmm_d_yyyy_SysDate 7 2" />

<VARIABLE NAME="%%mmmm_d_yyyy_SysDate" VALUE="%%MMMM%%MM_mmmm_d_yyyy_SysDate../%%NUMBER%%DD_mmmm_d_yyyy_SysDate../%%YYYY_mmmm_d_yyyy_SysDate." />

When %%$DATE = 20141203

Local variables are resolved to the following:

  1. %%YYYY_mmmm_d_yyyy_SysDate = 2014

    %%YY_mmmm_d_yyyy_SysDate = 14

    %%MM_mmmm_d_yyyy_SysDate = 12

    %%DD_mmmm_d_yyyy_SysDate = 03

  2. %%mmmm_d_yyyy_SysDate => %%MMMM%%MM_mmmm_d_yyyy_SysDate../%%NUMBER%%DD_mmmm_d_yyyy_SysDate../%%YYYY_mmmm_d_yyyy_SysDate.

    %%MMMM%%MM_mmmm_d_yyyy_SysDate => %%MMMM12 => December

    %%NUMBER%%DD_mmmm_d_yyyy_SysDate => %%NUMBER03 => 3

    %%YYYY_mmmm_d_yyyy_SysDate => 2014

Date variable (user defined) with offset

Tidal variable: <DATE-PROD-PREV.1.mmdd> _1_mmdd_DATE-PROD-PREV

Converts to:

<VARIABLE NAME="%%INPUT_1_mmdd_DATE-PROD-PREV" VALUE="%%$DATE" />

<VARIABLE NAME="%%OFFSET_VALUE_1_mmdd_DATE-PROD-PREV" VALUE="1" />

<VARIABLE NAME="%%RESULT_1_mmdd_DATE-PROD-PREV" VALUE="%%$CALCDATE %%INPUT_1_mmdd_DATE-PROD-PREV -%%OFFSET_VALUE_1_mmdd_DATE-PROD-PREV" />

<VARIABLE NAME="%%YYYY_1_mmdd_DATE-PROD-PREV" VALUE="%%SUBSTR %%RESULT_1_mmdd_DATE-PROD-PREV 1 4" />

<VARIABLE NAME="%%YY_1_mmdd_DATE-PROD-PREV" VALUE="%%SUBSTR %%RESULT_1_mmdd_DATE-PROD-PREV 3 2" />

<VARIABLE NAME="%%MM_1_mmdd_DATE-PROD-PREV" VALUE="%%SUBSTR %%RESULT_1_mmdd_DATE-PROD-PREV 5 2" />

<VARIABLE NAME="%%DD_1_mmdd_DATE-PROD-PREV" VALUE="%%SUBSTR %%RESULT_1_mmdd_DATE-PROD-PREV 7 2" />

<VARIABLE NAME="%%_1_mmdd_DATE-PROD-PREV" VALUE="%%MM_1_mmdd_DATE-PROD-PREV.%%DD_1_mmdd_DATE-PROD-PREV." />

When %%$DATE = 20100908

%%RESULT_1_mmdd_DATE-PROD-PREV = %%$CALCDATE %%INPUT_1_mmdd_DATE-PROD-PREV -%%OFFSET_VALUE_1_mmdd_DATE-PROD-PREV

%%$CALCDATE %%INPUT_1_mmdd_DATE-PROD-PREV -%%OFFSET_VALUE_1_mmdd_DATE-PROD-PREV => %%$CALCDATE %%INPUT_1_mmdd_DATE-PROD-PREV -1

%%$CALCDATE %%INPUT_1_mmdd_DATE-PROD-PREV -1 => %%$CALCDATE 20100908 -1 = 20100907

%%$CALCDATE is an variable function that calculates date offsets in days.

The offset value and operator (+ or -) is taken from VARMST_OFFSETS column. The conversion only supports tidal variables with offset of days and operators + or -.

Then %%YYYY_1_mmdd_DATE-PROD-PREV = 2010, %%YY_1_mmdd_DATE-PROD-PREV = 10, %%MM_1_mmdd_DATE-PROD-PREV = 09, %%DD_1_mmdd_DATE-PROD-PREV = 07

Then %%_1_mmdd_DATE-PROD-PREV => %%MM_1_mmdd_DATE-PROD-PREV.%%DD_1_mmdd_DATE-PROD-PREV.

%%MM_1_mmdd_DATE-PROD-PREV.%%DD_1_mmdd_DATE-PROD-PREV. => %%MM_1_mmdd_DATE-PROD-PREV.07

%%MM_1_mmdd_DATE-PROD-PREV.07 => 0907

Julian dates

Tidal variable: <SysDate.jj>

Converts to:

<VARIABLE NAME="%%SHORT_JULDAY_jj_SysDate" VALUE="%%JULDAY %%MINUS 0" />

<VARIABLE NAME="%%jj_SysDate" VALUE="%%SHORT_JULDAY_jj_SysDate." />

Then %%jj_SysDate => %%SHORT_JULDAY_jj_SysDate.

%%SHORT_JULDAY_jj_SysDate. => %%JULDAY %%MINUS 0

%%JULDAY %%MINUS 0 => 008 %%MINUS 0

%%MINUS is a variable function that subtracts two numbers. It eliminates the leading zeros.

008 %%MINUS 0=> 8

In Tidal the format jj should have a single leading zero in this example. So it is not a perfect conversion of Tidal behavior. However the format j works ok (same solution as above) and the format jjj will just be converted to %%JULDAY.

The string 'jj_SysDate' is a unique number to avoid overriding each other’s values.

 

Zena Additional Conversion Settings

The following table lists the Zena Additional Conversion Settings:

Conversion Settings

Description

General

First Day of the Week

Determines the first day of the week of your Control-M work environment.

Keep active for

Determines the maximum number of days that a Control-M job can wait for execution after the run date.

Valid values: 0-99 (integer) Default: 3

Events

JOBA-JTO-JOBB

Determines how two jobs are connected by creating a unique event in the format: JOBA_JOBB.

Cleanup Events

Determines to delete the event after the next job has finished running.

JOBA-ENDED-<Status>

Determines a dependence event between many jobs according its end status.

For more details, see Events.

Hadoop-Oozie Additional Conversion Settings

The following table lists the Hadoop-Oozie Additional Conversion Settings:

Conversion Settings

Description

General

First Day of the Week

Determines the first day of the week of your Control-M work environment.

Keep active for

Determines the maximum number of days that a Control-M job can wait for execution after the run date.

Valid values: 0-99 (integer) Default: 3

Events

JOBA-JTO-JOBB

Determines how two jobs are connected by creating a unique event in the format: JOBA_JOBB.

Cleanup Events

Determines to delete the event after the next job has finished running.

JOBA-ENDED-<Status>

Determines a dependence event between many jobs according its end status.

For more details, see Events.

SAP Additional Conversion Settings

The following table lists the SAP Additional Conversion Settings:

Parameter

Description

General

Default Connection Profile

Defines the connection profile name, which appears in the Connection Profile field in the Job Properties pane in Control-M.

By adding a Default account value, the connection profile is automatically added to a Control-M for SAP R/3 job.

You still need to define the connection profile in the Control-M Configuration Manager (CCM).

Default Target Server

Defines the default target server. The default value appears in the Exec. Target field in the Job Properties pane in Control-M client.

  • If unspecified, SAP determines a parameter value during runtime.

  • To change the target server to group, after loading the converted data into Control-M, in Control-M client use the find and update feature to search for the target server and replace it with group.

Set Starting Event from Event ID and Parameters

Converts the SAP job Event ID and EVENT param to the After event parameter in the Start Event field in the Job Properties pane in Control-M.

When the check box is selected, if the Event ID is SAP_END_OF_JOB, a Control-M event is created between the predecessor and the successor jobs.

Include periodic values

Determines whether SAP periodic values are converted to Control-M cyclic values.

Convert SAP planned start date/time to Control-M SAP jobs

Converts SAP application jobs start date and/or time to Control-M for SAP start date and/or time.

Job Mode

Copy

Copies an existing job in SAP, which enables you to set the job count setting from the drop-down list.

Create

Creates a new SAP job.