This section contains parameters that control the Health Checker tasks in the Control‑M monitor.

Table 16 Health Checker parameters

Parameter

Description

Act

HCDELAYT

The minimum time interval in seconds, interpreted as a "process delay" in the Control-M Health Checker. If this parameter is set to 0 the report is not produced.

  • Mandatory
  • Valid values are 0-999
  • Default: 030

 

HCHECKER

Whether Control‑M monitor should use the Health Checker interface to communicate with IBM Health Checker.

  • Mandatory

Valid values are:

  • Y - Health Checker interface is enabled. Control‑M monitor will communicate with IBM Health Checker. Default.
  • N - Health Checker interface is disabled. Control‑M monitor will not communicate with IBM Health Checker.

1

HCJDAYS

The number of days that defines a job as "dormant."

  • Mandatory
  • Valid values: 1-999
  • Default: 365 days

1

HCJINTRV

The interval of time, in hours, between checks of the "dormant" jobs in the Active Jobs file. Dormant jobs have been sitting in the Active Jobs file for more than the specified days in the HCJDAYS parameter.

  • Mandatory
  • Valid values: 0-999
  • Default: 24 hours

1

HCLINTRV

The interval time, in minutes, between checks for issues in the IOALOG Index file.

If this parameter is set to 0, the check is not processed.

  • Valid values are 0-9999
  • Default: 0

1

HCLOGIDX

Threshold percentage for the level of correspondence between the IOALOG Index file and the IOA Log. A warning is issued when the IOA log is indexed below this percentage.

  • Valid values are 1-99
  • Default: 85%

1

HCMEMA16

Threshold amount of virtual storage memory (in megabytes) above the 16MB line. A warning is issued when the amount of available storage memory falls below this value.

  • Valid values are 0-999
  • Default: 50 MB

1

HCMEMB16

Threshold amount of virtual storage memory (in kilobytes) below the 16MB line. A warning is issued when the amount of available storage memory falls below this value.

  • Valid values are 0-9999
  • Default: 256 KB

1

HCMINTRV

The interval of time, in minutes, between parameter checks. Each check verifies that the parameter values in the CTMPARM member in the IOA PARM library are the same as the CTMPARM settings currently in memory.

If this parameter is set to 0, the check is not processed.

  • Mandatory
  • Valid values are 0-999
  • Default: 30 minutes

 

HCPINTRV

The interval of time, in minutes, between checks for job processing delays. An exception message is produced based on internal tables, maintained by the various Control‑M subtasks (such as submitter, selector, and spyer), which determines whether a job being processed by these components is experiencing excessive delays. These delays could indicate a job is not responding (hang condition).

If this parameter is set to 0, the check is not processed.

  • Mandatory
  • Valid values are 0-999
  • Default: 1 minute

1

HCSINTRV

The interval time, in minutes, between checks for issues in Control-M Monitor virtual storage consumption.

If this parameter is set to 0, the check is not processed.

  • Valid values are 0-999
  • Default: 3 minutes

1

HCTINTRV

The interval of time, in minutes, between checks of the status of the Active Jobs file. An exception message is produced when the entries as a percentage of the maximum allowed, exceeds the threshold defined in the AJFTHRSH parameter (for more information, see CKP section).

If this parameter is set to 0, the report is not produced.

  • Mandatory
  • Valid values are 0-999
  • Default: 1 minute

1