The Ex-ComponentStopping Sub Application contains jobs that are used to shut down (stop) Control-M components. Normally, shut down of components is not required. However, situations can arise thuire component shutdown. These situations can range from extreme emergencies (as handled in this sample draft) to minor malfunctions, repairs, or maintenance.
Each job in this Sub Application shuts down a single component. With the exception of the job that shuts down the gateway, which must run last, the jobs in this Sub Application can run in any order or sequence.
Defining jobs that stop the GCS, and GUI servers and CMS and BIM
These following jobs should run only after ShutDownAllSystems (in the Ex-EmergencyProcs Sub Application) has ended successfully:
Defining jobs that implement operating system commands, and other general information about the jobs
The jobs contain the following:
ctl -u emuser -p empass -C component -all -cmd stop
where component is the relevant Control-M component (GAS, GCS, etc).
Defining a job that stops the gateway
The GatewayStopped job stops the Gateway. It should only be run after the other components have been stopped. Like its predecessor jobs, this job issues an operating system Stop command.
The job contains the following:
ctl -u emuser -p empass -C Gateway -all -cmd stop.
Parent Topic |