The following table describes parameters that enable you to define a Control-M/Server component, as described in Defining a Control-M/Server component.
Field |
Description |
---|---|
Name |
Defines the name of the Control-M/Server. The name can be a maximum of 20 alphanumeric characters long. You can include symbols, but do not use blank spaces. |
Platform |
Determines whether the Control-M/Server is installed on a distributed or z/OS operating system. If your operating system is UNIX or Windows select Distributed. |
ID |
Defines a unique 3-character code (such as 999 or NYC) that Control-M/EM uses to identify each Control-M/Server |
Version |
Determines the version number of the Control-M/Server |
Description |
Provides a description of the Control-M/Server |
Contact |
Defines the name of the contact person who is responsible for Control-M/Server maintenance |
Time Zone |
Determines the time zone where the Control-M/Server is located. NOTE: Although time zone definitions in the northern hemisphere are set to summer Daylight Saving Time, definitions in the southern hemisphere are set to winter. In Sydney, Australia, winter time (GMT+10:00) is from March 25 at 03:00 until October 1 at 02:00. All other dates are GMT+11:00 (summer time). The time label for Sydney is defined as follows: SYD (GMT+11:00) FROM 25.03 03:00 TO 01.10. 02:00 (GMT+10:00) NOTE: This parameter is only enabled if the Control-M/Server is set to Un-Managed. |
Start Day |
Determines the first day of the business week. The settings on the Control-M/Server computer must match these settings. NOTE: This parameter is only enabled if the Control-M/Server is set to Un-Managed. |
New Day Time |
Determines the time of day that the New Day procedure is performed on the Control-M/Server. The settings on the Control-M/Server computer must match these settings. NOTE: This parameter is only enabled if the Control-M/Server is set to Un-Managed. |
Daylight Savings Time |
Determines the following:
|
Control-M/Tape |
Determines whether Control-M/Tape is installed on this computer with Control-M/Server (z/OS only) |
Control-M/Restart |
Determines whether Control-Restart is installed on this computer with Control-M/Server (z/OS only) |
Control-M/Analyzer |
Determines whether Control-Analyzer is installed on this computer with Control-M/Server (z/OS only) |
Upper Case |
Determines whether to restrict user input to upper case letters only in job attributes. If you select this option, you cannot change it without fixing all the job attributes. |
Enable |
Determines whether the Control-M/Server is enabled |
Statistics Field |
Defines the job attribute which is used as the key for statistics collection according to Jobname or Memname. The settings on the Control-M/Server computer must match these settings. |
Protocol |
Determines which protocol Control-M/Server uses to communicate with Control-M/EM |
Host |
Defines the name of Control-M/Server host |
Control-M/EM Port |
Defines the TCP/IP port number that Control-M/Server uses to connect to Control-M/EM |
Gateway |
Defines a new Gateway that is used to connect to Control-M/EM, as described in Defining a Control-M/EM component. |
Synchronization mode |
Determines when, if, and how to synchronize data between Control-M/Server and Control-M/EM, as follows:
|
Parent Topic |