Previous Topic

Next Topic

Book Contents

Book Index

[NO]STEPADJUST parameters

The STEPADJUST parameter permits Automatic Step Adjustment to be performed; the NOSTEPADJUST parameter prevents Automatic Step Adjustment from being performed. As the default, STEPADJUST, which permits Automatic Step Adjustment, does not need to be explicitly specified. If Automatic Step Adjustment is not desired, NOSTEPADJUST is specified.

Step adjustment is accompanied by the CTR183I and CTR039I messages. If step adjustment continues to the first job step and no restart step is found, Control-M/Restart fails the job’s restart. This failure is accompanied by the CTR184S error message.

If step adjustment is needed, but step adjustment is disabled, job restart is terminated with a non-zero return code.

Example

Step adjustment is not performed:

NOSTEPADJUST

Parent Topic

Control parameters in the Control-M/Restart PARM library