While in the Subsystems Display screen, the display type can be changed using the DISPLAY command. The format of the command is:
DISPLAY x
In this command, x is the identifying letter for the desired type. DISPLAY can be abbreviated to DI.
Note: For a list of display types, enter DISPLAY ? to show the Display Options window. To select a display type in the window, type S (Select) in the Option field next to the ID. To exit the window without selecting a display type, press PF03/PF15 (END).
Example
DI A
displays the All Fields display type
Valid predefined display types are:
Display Type D (Default)
Figure 64 shows an example of the Default display type for the Subsystems Display screen.
Figure 64 Automation Options SUBSYS Option Default Display Type (D)
--------------------- CONTROL-O SUBSYSTEMS DISPLAY -------< D >-------(OA)
COMMAND ===> SCROLL===> CRSR
SUBSYSTEM-NAME STATUS SSCT-ADDRESS SSVT-ADDRESS
O21P ACTIVE 00CFF4A0 00D40AD4
JES2 ACTIVE 00D6C898 00D3E658
MSTR ACTIVE 00D638A8 00D63790
SMS ACTIVE 00D6C010 00D404C0
BLSR ACTIVE 00D6C870 00D63EF0
FDR INACT 00D6C848 00000000
PDSM ACTIVE 00D63678 00D6ACE8
PLD INACT 00D63650 00000000
GOSM INACT 00D63628 00000000
IRLM INACT 00D63750 00000000
JRLM INACT 00D63728 00000000
JESD INACT 00D63700 00000000
JESX INACT 00D63DC8 00000000
JESY INACT 00D63DA0 00000000
NETV ACTIVE 00D63D78 00FBC168
CNMP INACT 00D63D50 00000000
TSSO INACT 00D63D28 00000000
GPSM ACTIVE 00D63D00 00D8A358
PROD ACTIVE 00D63CD8 00D405CC
PRD4 INACT 00D63CB0 00000000
CMDS: SHPF, REFRESH, AUTO 15.05.54
Fields in the Default (D) Display Type
The fields in the Default (D) display type are shown in Table 76.
Table 76 Fields of the SUBSYS Option Default Display Type (D)
Field |
Description |
---|---|
<D> |
Indicates Default display type. |
SUBSYSTEM |
Subsystem identification (1 to 4 character string). |
STATUS |
Subsystem status. Valid values are:
|
SSCT ADDRESS |
Address of the Subsystems Control table. |
SSVT ADDRESS |
Address of the Subsystems Vector table. |
Display Type A (All Fields)
Figure 65 shows an example of the All Fields display type for the Subsystems Display screen. This display type is requested by specifying the DISPLAY A command (abbreviated DI A) in the COMMAND field of the screen.
Figure 65 SUBSYS Options All FIelds Display Type (A)
--------< A >-------- CONTROL-O SUBSYSTEMS DISPLAY -------------------(OA)
COMMAND ===> SCROLL===> CRSR
SUBSYSTEM-NAME STATUS SSCT-ADDRESS SSVT-ADDRESS
O21P ACTIVE 00CFF4A0 00D40AD4
ACTIVE FUNCTIONS 07-AL 09-WT 10-CM 14-DM 16-DA
17-DA 18-DA 19-DA 38-CI 39-AG
JES2 ACTIVE 00D6C898 00D3E658
ACTIVE FUNCTIONS 01-SO 02-CS 03-CS 04-ET 05-JS
06-AL 07-AL 08-EN 09-CT 10-CM
11-US 12-JT 13-RQ 16-DA 17-DA
18-DA 19-DA 20-RR 21-RR 53-
64- 70- 71- 75-
MSTR ACTIVE 00D638A8 7 00D63790
ACTIVE FUNCTIONS 04-ET 05-JS 06-AL 08-EN 09-WT
10-CM 12-JT 14-DM 15-VS 32-CF
33-WT 48- 50- 63- 68-
72- 73-
SMS ACTIVE 00D6C010 00D404C0
ACTIVE FUNCTIONS 08-EN 15-VS 55-
CMDS: SHPF, REFRESH, AUTO 15.25.30
Parent Topic |