Figure 34 is an example of the Show Option window, which enables you to specify criteria to determine which active rules are included in the status display. To open the window, type SHOW in the COMMAND field of the Rule Status screen, or press PF02/PF14. Change criteria by making the desired changes and pressing Enter.
Figure 34 Rule Status Screen Show Option Window
---------------------------- CONTROL-O RULE STATUS ------------<D>---------(OS)
COMMAND ===> +-----------------------------------------------------------+
RULES: 450 MSG| PLEASE SELECT SHOW OPTION |
O RULE TYP -| RULE |
CMEMJOBA R S| GROUP |
JOBEND X S| |
CMEMJOB D S| LIBRARY |
$HASP493 M J| TABLE |
CT0139I M C| ==== STATUS ==== |
CT0621I M C| ACTIVE Y EXECUTING Y WAIT ACTIVE Y HELD Y SUSPEND Y |
CTO623I M C| ==== RULE TYPE ==== |
COSCLEAR E I| MSG STR COM EVN DSN INT JOB RUL STP OMG PCM MVI SMS SYS |
COSINI C C| Y Y Y Y Y Y Y Y Y Y Y Y Y Y |
COSCMD* C E| PRIORITY FROM TO CONTINUE SEARCH YES Y NO Y |
COSTERM C T| |
COSBOUNZ C B| ACTIVATION# FROM TO |
COSUP C S| |
COSDOWN C S| OWNER MODE: PROD Y TEST Y LOG Y |
COSOBJ * C S+-----------------------------------------------------------+
COSCUP * C SYNTAX SUGARING FOR 0 ACTIVE
COSCDOWN * C SYNTAX SUGARING FOR 0 ACTIVE
OPTIONS: ? WHY H HOLD D DEL F FREE M MODE C CANCEL R RESUME 11.17.01
Note: Selection criteria marked with the symbol P act on a prefix basis.
Table 51 shows the criteria that can be specified in the Rule Status screen Show Options window.
Table 51 Rule Status Screen Show Option Window Criteria
Criteria |
Description |
---|---|
RULEP |
Includes only rules having the indicated name (prefix). A maximum of five values can be specified. |
GROUPP |
Includes only rules belonging to the specified group (prefix). A maximum of four values can be specified. |
LIBRARYP |
Includes only rules whose members are found in the specified library (prefix). |
TABLEP |
Includes only rules found in the specified table (prefix). A maximum of five values can be specified. |
STATUS |
The STATUS fields in the Show Option window are
Valid values for each of these STATUS fields are:
|
RULE TYPE |
The type of the rule. Valid RULE TYPEs are:
Valid values for each of these RULE TYPEs are:
|
PRIORITY FROM/TO |
Includes rules whose priority is within the specified range. A FROM or TO value can be specified without specifying both values. In this parameter, 0 ¹ blank. |
CONTINUE SEARCH YES/NO |
For both CONTINUE SEARCH YES and CONTINUE SEARCH NO, you can specify Y or N in the Show Option window. The effect is as follows:
|
ACTIVATION# FROM/TO |
Includes rules with a number of activations (that is, with a value in the ACTIVATED field) that is within the specified range. A FROM or TO value can be specified without specifying both values. |
OWNERP |
Includes rules belonging to the specified owner. |
MODE |
MODE fields in the Show Option window are:
You can specify Y or N in each of the MODE fields. The effect is as follows:
|
Parent Topic |