The Job Order Execution History screen is displayed when option V (View Sysout) is entered on the Active Environment screen. The Job Order Execution History screen lists all runs of the job and displays relevant execution information for each run.
This option is used for jobs that have executed at least once and whose SYSDATA has been automatically archived by the Control-M monitor as part of Control-M/Restart processing (Auto-Archive=Y). The V option does not support the viewing of output on the spool or output that has been archived by a Control-M SYSOUT F function.)
Figure 61 §Restart§ Job Order Execution History Screen
------------------------ JOB ORDER EXECUTION HISTORY ---------------------(3.V)
COMMAND ===> SCROLL===> CRSR
MEMNAME MSGCMPR OWNER M05A ORDERID 00051 ODATE 060601
O JOBNAME JOBID DATE START ELAPSED PAGES MAX RC --------- STATUS ---------
PRDYLLM 01318 060601 21:40 1.46 00007 S222 ENDED- NOT "OK" - ABENDED
PRDYLLM 01425 060601 21:56 1.21 00014 C0008 ENDED- NOT "OK" DUE TO CC
PRDYLLM 01447 060601 22:01 1.50 00014 ENDED- OK
======= >>>>>>>>>>> BOTTOM OF ACTIVE JOB ORDER HISTORY LIST <<<<<<<<<<< =======
OPTION: S SELECT 11.41.04
By default, older data are displayed before more recent data (that is, in FIFO order – first in, first out), so that the first run of the job is shown first. If, however, the user profile has been customized accordingly, data is displayed in LIFO order (last in, first out).
The Job Order Execution History screen is pre-configured to the D (Default) display type. Additional display types may be defined by the INCONTROL administrator. To display a different display type on the screen, type command DISPLAY x (abbreviated DI x) where x is the identifying letter of the display type (such as DI D).
To return to the Active Environment screen, press the END key (PF03/PF15).
Parent Topic |