Example for DO OK

When PROCST UPDA in PGMST STEP08 finishes executing with a condition code less than C0008, it is considered OK.

Figure 200 DO OK Parameter Example

JOB: PRDKPL02 LIB CTM.PROD.SCHEDULE                     TABLE: PRODKPL

COMMAND ===>                                           SCROLL===> CRSR

+--------------------------------------------------------------------+

  OUT                                                                 

  AUTO-ARCHIVE Y          SYSDB    Y      MAXDAYS      MAXRUNS        

  RETENTION:  # OF DAYS TO KEEP 030  # OF GENERATIONS TO KEEP         

  SYSOUT OP   (C,D,F,N,R)                                        FROM

  MAXRERUN     RERUNMEM                             INTERVAL   FROM    

  STEP RANGE         FR (PGM.PROC)          .        TO        .      

  ON PGMST STEP08   PROCST UPDA     CODES <C0008                  A/O

    DO OK                                                         

    DO                                                                

  ON PGMST          PROCST          CODES                         A/O

    DO                                                                

  ON SYSOUT                                     FROM 01 TO 132    A/O

    DO                                                                

  ON VAR                                                              

    DO                                                                

  SHOUT WHEN           TIME       +     DAYS     TO            URGN   

    MS                                                                

======= >>>>>>>>>>>>>>> END OF SCHEDULING PARAMETERS <<<<<<<<<< ======

COMMANDS: EDIT, DOC, PLAN, JOBSTAT                          15.16.03

Parent Topic

DO OK: Post–Processing Parameter