Previous Topic

Next Topic

Book Contents

Book Index

DEFINITION ACTIVE: Basic Scheduling Parameter

Specifies the time limits (FROM, UNTIL) for using the job scheduling definition.

Figure 181 DEFINITION ACTIVE Parameter Format

Optional. The parameters include the subparameters described in Table 175.

Table 175 DEFINITION ACTIVE Subparameters

Subparameter

Description

FROM

6-digit date. The job scheduling definition will only be used if the ordering date is later than the date specified. Default: ‘  ‘ (Blank)

UNTIL

6-digit date. The job scheduling definition will only be used if the ordering date is earlier than the date specified. Default: ‘  ‘ (Blank)

The format of either the FROM or UNTIL subparameters may be ddmmyy, mmddyy, or yymmdd, depending on your local site standard, as set by the DATETYP parameter in the IOAPARM member in the IOA PARM library.

Parent Topic

Job Production Parameters