Previous Topic

Next Topic

Book Contents

Book Index

Parameters

The input parameters for the utility are specified in the stream referred by the SYSIN DD statement. All parameters have keyword format. They are described in Table 11.

Table 11 CTDSARRS input parameters

Parameter

Description

TSEQ

The input CA-View archive tape dataset seq. number. Maximum length is 5 digits. Obligatory.

BKPMIS

The Control-D backup mission name. Maximum length is 8. Optional.

This name is stored to the created $SYSDATA records. Then the reports will be picked up by this backup mission.

MIGMIS

The Control-V migration mission name. Maximum length is 8. Optional.

This name is stored to the created $SYSDATA records. Then the reports will be picked up by this migration mission.

PREF

The high level qualifier (prefix) of the created Control-D CDAM files. Maximum length is 7. Optional. If it is not specified the AMPREF parameter from CTDPARM is used.

MAXN

Maximum number of the reports to be restored from the specified CA‑View archive tape file. Maximum length is 6 digits. Optional.

If it is not specified, all reports are restored.

FORCE

Valid values are:

  • NO - the utility does not take for restoring the reports restored in the previous utility runs. Default. So, if not all reports from a CA-View archive tape file are restored in one utility run because the limitation specified in the MAXN parameter is reached, the next utility run will not take the restored reports again but will take other reports for restoring.
  • YES - the restored reports are taken for restoring again if they have not been backed up by the Control-D tools yet. The reports which are already backed up by the Control-D tools cannot be restored again from the CA-View tape, even if FORCE=YES is specified.

Parent Topic

Utility CTDSARRS - Massive restore CA-View archived reports to Control-D