This section contains general parameters.

Table 18 General (miscellaneous) parameters

Parameter

Description

Act

ARMELMNT

The name that represents Control‑M as an element of automatic restart management (ARM).

When this parameter is enabled, the operating system automatically restarts Control‑M after an unexpected failure, using ARM.

When specifying an element name, apply the following rules:

  • The name can be from 1 through 12 characters. Control‑M appends to this name the 4-character system identifier on which the element originally registered, which makes this name unique across the Sysplex.
  • Valid characters are uppercase alphabetic characters, the digits 0 through 9, and the following symbols: $, #, @ and underscore (_).
  • The first character may not be a number.
  • Element names that start with A through I, and SYS, are reserved for use by IBM.

Valid values are:

  • N or NO or '  ' (Blank) – ARM for Control‑M is not enabled. The operating system does not attempt to restart Control‑M if it fails unexpectedly. Default.
  • policy_name – Name of the ARM policy. ARM for Control‑M is enabled. The operating system attempts to restart Control‑M if it fails unexpectedly.

This element name must exactly match the ELEMENT and ELEMENT_NAME ARM policy parameters, or the operating system will use the default policy. For more information, see the section on ARM support in the Control‑M chapter of the INCONTROL for z/OS Administrator Guide.

 

DOCUT

Whether DOCU/TEXT is installed at the site.

For more information on this parameter, see the "Installing Control-M" chapter in the INCONTROL for z/OS Installation Guide: Installing.

2

JSCAN

Whether a JOB/SCAN product is installed at the site.

For more information on this parameter, see the "Installing Control-M" chapter in the INCONTROL for z/OS Installation Guide: Installing.

2

M622RC4

Causes the CTMRELRS utility to end with a return code of 4, instead of a return code of 12, if message CTM622E is displayed.

Valid values are:

  • Y – The utility ends with a return code of 4.
  • N – The utility ends with a return code of 12. Default.

 

MVBO

Whether MAINVIEW Batch Organizer is installed at the site.

  • Mandatory

Valid values are:

  • Y – MAINVIEW Batch Optimizer is installed at the site. Control‑M and IOA integration, and support for MAINVIEW Batch Optimizer is required.
    Control‑M concurrently submits jobs connected with MAINVIEW Batch Optimizer pipes. MAINVIEW Batch Optimizer pipes data and split step information can be viewed through the IOA online environment, using option W on the Control‑M Active Environment screen (Screen 3). For further information about Control‑M and IOA integration with MAINVIEW Batch Optimizer, see the Control‑M for z/OS User Guide and the MAINVIEW Batch Optimizer Job Optimizer Reference Manual.
  • N – MAINVIEW Batch Optimizer is not installed at the site. Control‑M and IOA integration, and support for MAINVIEW Batch Optimizer is not required. Default.

1

Parent Topic

Control-M parameter customization