If necessary, modify the Control‑O current release installation parameters. Verify that the values assigned to the following parameters in the current release installation are suitable for production. You can change the values by using the "CTOPARM Post‑Installation" major step, under Product Customization for Control-O, in ICE Customization.
Table 20 Control‑O installation parameters
Parameter |
Additional considerations |
---|---|
DAYTIMEO |
This definition must kept in the active Control-O |
EMCSCONS |
The definitions of the Extended MCS must not conflict with those of the other active Control‑O system. For example you should
|
JCMDSSN |
This definition must not conflict with that of the other active Control‑O system. |
NUMCONS |
If EMCSCONS is assigned, this is unnecessary. |
Save parameters by performing the "Save Parameters into Product Libraries" minor step.
Check the KOATERM blocks in the IOAKPRM member in the IOA.PARM library. Verify that all CPUs defined in the IOACPRM member (in the IOA.PARM library) are also defined for KOA.
Parent Topic |