Messages RSTM00 through RSTMxx

This group includes messages for the Control-D, Control-D/Image, and Control-D/Page on Demand products.

RSTM01W AJF/CONDITIONS JOURNALING TERMINATED - RESTORATION BEYOND THIS TIME NOT POSSIBLE

Explanation: Logging to the journal file was terminated due to a detected error.

This message is preceded by a message indicating the cause of the error.

The Control-M monitor terminates the Journal facility and displays WTOR message CTML12W, which asks the operator how the monitor should proceed.

Corrective Action: Respond to message CTML12W.

RSTM02I AJF/CONDITIONS JOURNALING STARTED

Explanation: This information message indicates that Control-M started logging updates to the Journal file.

Changes made to the Active Jobs file and to prerequisite conditions in the IOA Conditions file are recorded in the Journal file.

Corrective Action: No action is required.

RSTM03E text

Explanation: This message is produced if an abend occurs while Control-M is writing to the Journal file.

The Control-M monitor displays data about the abend, meaning the text in this message.

The Control-M monitor terminates the Journaling facility and displays WTOR message CTML12W.

Corrective Action: Respond to message CTML12W.

RSTM04I AJF/CONDITIONS JOURNALING CLOSED NORMALLY

Explanation: This information message indicates that Control-M Journaling ended normally.

The Journaling facility was terminated in response to an operator command, or as part of Control-M shutdown.

Corrective Action: No action is required.

RSTM05S AJF/CONDITIONS JOURNALING INITIALIZATION FAILURE

Explanation: The Control-M journaling facility could not be started because the Journal file or another file required for journaling could not be opened.

The above message describes the reason for the problem.

The Control-M monitor terminates the Journaling facility and displays WTOR message CTML12W, which asks the operator whether to continue without journaling or shut down the Control-M monitor.

Corrective Action: Respond to message CTML12W.

RSTM06S JOURNAL FILE RECORD 0 FORMAT ERROR

Explanation: The record length of the Control-M journal file was incorrect.

This message is preceded by a message describing the specific cause of the problem.

The Control-M monitor terminates the Journaling facility and displays WTOR message CTML12W, which asks the operator whether to continue without journaling or to shut down the Control-M monitor.

Corrective Action: Respond to message CTML12W.

RSTM07S JOURNAL/AJF MISMATCH: FIELD=fldname

Explanation: The Control-M Journaling facility could not be started because the specified journal file does not match the Active Jobs file used by the Control-M monitor.

In this message, fldname is the name of the field in the Active Jobs file which does not match the corresponding field in the Journal file.

The Control-M monitor terminates the Journaling facility and displays WTOR message CTML12W.

Corrective Action: Respond to message CTML12W.

RSTM08S GETMAIN FAILURE IN PROGRAM CTMRSTM

Explanation: Sufficient storage could not be obtained for Journal file processing.

The Control-M monitor terminates the Journal facility and displays WTOR message CTML12W. CTML12W asks the operator to either continue without journaling or shut down the Control-M monitor.

Corrective Action: Respond to message CTML12W.

RSTM09S BUFFER OVERFLOW ERROR

Explanation: An internal error was detected during Journal file processing.

The Control-M monitor terminates the Journal facility and displays WTOR message CTML12W.

Corrective Action: Respond to message CTML12W. Prepare the Control-M monitor full output and contact BMC Customer Support.

RSTM10S LUW RECORD GENERATION ERROR

Explanation: A error occurred while writing the LUW syncpoint record to the Journal file.

The LUW syncpoint record is the last synchronization point in the Journal file and verifies the completion of all records previously recorded in the Journal file. Without the LUW syncpoint record, records in the Journal file cannot be verified as complete.

The Control-M monitor terminates the Journal facility and displays WTOR message CTML12W.

Corrective Action: Respond to message CTML12W.

RSTM12E JOURNAL FILE DCB ABEND EXIT INVOKED: SYSTEM CC=X’sys’, RC=rc

Explanation: An abend occurred while writing to the Journal file.

sys and rc are the system codes and return codes which describe the abend.

The Control-M monitor terminates the Journal facility and displays WTOR message CTML12W.

Corrective Action: Respond to message CTML12W.

RSTM15I AJF/CONDITIONS JOURNALING ACTIVITY SUSPENDED

Explanation: This information message indicates that journaling has been suspended due to New Day processing.

During New Day processing, Control-M always suspends writing to the Journal file.

Journaling is automatically resumed after completion of New Day processing.

Corrective Action: No action is required.

RSTM16I AJF/CONDITIONS JOURNALING ACTIVITY RESTORED

Explanation: This information message indicates that Control-M resumed writing to the Journal file after completing New Day processing.

Corrective Action: No action is required.

RSTM17S AJF/CONDITIONS JOURNAL SEARCH FAILURE

Explanation: An error was encountered during a search of the Control-M Journal file.

During Control-M monitor startup, the journal file is searched for data that may have been added to the Active Jobs File while the Control-M monitor was down.

The Control-M monitor stops journaling and displays WTOR message CTML12W.

Corrective Action: Reply to message CTML12W, which follows.

Parent Topic