MTO780I INITIALIZATION OF OPENEDITION ENVIRONMENT STARTED

Explanation: This information message is the normal start message issued during initialization of Control-O or the CMEM monitor when using OS/390 version 2.4 or later.

Control-O or the CMEM monitor detected an environment which supports the MVS OpenEdition interface with Control-O and began initializing the OpenEdition environment.

Corrective Action: No action is required.

MTO781I OPENEDITION INTERFACE MODULE SUCCESSFULLY LOADED

Explanation: This information message is the normal start message issued during initialization of Control-O or the CMEM monitor when using OS/390 version 2.4 or later.

Control-O or the CMEM monitor loaded the OpenEdition interface module into storage. This message is issued only for the first Control-O or CMEM monitor in the system.

Corrective Action: No action is required.

MTO782I SUBSYSTEM REGISTERED WITH OPENEDITION INTERFACE

Explanation: This information message is the normal start message issued during initialization of Control-O or the CMEM monitor when using OS/390 version 2.4 or later.

The current Control-O or CMEM subsystem has registered itself (meaning, recorded its name) with the OpenEdition interface in order to receive OpenEdition events from the interface.

Corrective Action: No action is required.

MTO783I INITIALIZATION OF OPENEDITION ENVIRONMENT ENDED SUCCESSFULLY

Explanation: This information message is the normal start message issued during initialization of Control-O or the CMEM monitor when using OS/390 version 2.4 or later.

OpenEdition support for the current Control-O or CMEM monitor is successfully installed. Control-O or CMEM will trigger rules based on OpenEdition events.

Corrective Action: No action is required.

MTO784W OS/390 VERSION IS 2.4 OR HIGHER BUT PTF LEVEL IS TOO LOW

Explanation: Control-O or CMEM tried to install OpenEdition support but found an incompatible PTF level.

Control-O or CMEM support for OpenEdition events is required for OS/390 version 2.4 and later. The PTF level in MVS is too low to install the OpenEdition interface.

The following system actions occur:

Corrective Action: Install IBM PTF for APAR OW36163, which enables Control-O or CMEM support for OpenEdition.

MTO785W UNABLE TO REGISTER WITH OPENEDITION INTERFACE: rsn

Explanation: The Control-O or CMEM subsystem could not register with the OpenEdition interface during initialization.

Possible values for rsn are:

Initialization of the OpenEdition interface fails. Initialization of Control-O or the CMEM monitor continues. Control-O or the CMEM monitor will not be able to handle OpenEdition events, such as data set triggering based on FTP transmissions. If the value of rsn is NO SUPPORT FOR DYNAMIC CTOSSI, the Control-O or CMEM interface for USS is disabled.

Corrective Action: If the value of rsn is TOO MANY SUBSYSTEMS, shut down a different Control-O or CMEM monitor and restart the current monitor.

If the value of rsn is LOCK CANNOT BE OBTAINED, restart the current monitor. If the problem persists, call your INCONTROL administrator.

(version 6.1.00) If the value of rsn is NO SUPPORT FOR DYNAMIC CTOSSI, apply the following fixes to all environments: PA01142, PA01143, PA01144 and PA01147.

MTO786W LOAD OF OPENEDITION INTERFACE MODULE FAILED: rsn

Explanation: During initialization of the OpenEdition interface, Control-O or CMEM could not load the OpenEdition support module.

In this message, rsn is one of the following:

If the value of rsn is LOAD TO PRIVATE REGION FAILED: Control-O or CMEM monitor could not load the OpenEdition support module in its own private region.

If the value of rsn is CSA GETMAIN FAILED: Control-O or the CMEM monitor could not acquire storage in the Common Service Area (CSA) for the OpenEdition support module.

If the value of rsn is LOAD TO CSA FAILED: Control-O or the CMEM monitor could not load the OpenEdition support module to the Common Service Area (CSA).

The following system actions occur:

Corrective Action: If the value of rsn is LOAD TO PRIVATE REGION FAILED: determine the cause of the failure using previous messages. Possible causes are:

If the value of rsn is CSA GETMAIN FAILED, make sure that the CSA has at least 8K of free storage, then restart the Control-O or CMEM monitor.

If the value of rsn is LOAD TO CSA FAILED, use the contents of previous messages to determine the cause of the failure.

MTO787E INITIALIZATION OF OPENEDITION ENVIRONMENT FAILED

Explanation: Control-O or CMEM tried to install the OpenEdition interface but an error occurred during initialization of the interface.

The following system actions occur:

Corrective Action: Look for previous messages which explain the cause of the failure. Call your INCONTROL administrator.

MTO788I SUBSYSTEM ALREADY REGISTERED WITH OPENEDITION INTERFACE

Explanation: This information message indicates that Control-O or the CMEM monitor tried to register with the OpenEdition interface but found the subsystem was already registered.

A possible cause is a previous uncompleted termination of CMEM or Control-O.

Initialization of the OpenEdition interface continues.

Corrective Action: No action is required.

MTO789W OPENEDITION ADDRESS SPACE HAS NOT COMPLETED INITIALIZATION

Explanation: During Control-O startup, Control-O tried to activate OPENEDITION (UNIX for MVS) support. The attempt failed for one of the following reasons:

The preconditions for using Control-O/ OPENEDITION (UNIX for MVS) are:

The Control-O startup process completes but does not support OPENEDITION.

Corrective Action: If the system is earlier than OS/390 version 2.4, ignore this message. Otherwise, apply IBM APAR OW36163.

MTO790I DEACTIVATION OF OPENEDITION ENVIRONMENT STARTED

Explanation: This information message is the normal message issued during termination of Control-O or the CMEM monitor when using OS/390 version 2.4 or later.

Control-O or the CMEM monitor detected an active OpenEdition interface environment and started its termination procedure.

Corrective Action: No action is required.

MTO791I SUBSYSTEM REMOVED FROM OPENEDITION INTERFACE

Explanation: This information message is the normal message generated during termination of Control-O or the CMEM monitor when using OS/390 version 2.4 or later.

The current Control-O or CMEM subsystem removed itself from the OpenEdition interface in order to stop receiving OpenEdition events.

Corrective Action: No action is required.

MTO792I OPENEDITION INTERFACE MODULE REMOVED

Explanation: This information message is the normal message issued during termination of Control-O or the CMEM monitor when using OS/390 version 2.4 or later.

Control-O or the CMEM monitor removed the OpenEdition support module from storage. This message is displayed only during termination of the last Control-O or the CMEM monitor in the system.

Corrective Action: No action is required.

MTO793I DEACTIVATION OF OPENEDITION ENVIRONMENT ENDED SUCCESSFULLY

Explanation: This information message is the normal message issued during termination of the CMEM monitor or Control-O when using OS/390 version 2.4 or later.

The OpenEdition interface for the current Control-O or CMEM monitor has been successfully removed.

Corrective Action: No action is required.

MTO794W DEACTIVATION OF OPENEDITION ENVIRONMENT FAILED

Explanation: Control-O or CMEM tried to remove OpenEdition support but encountered an error.

An error occurred during termination of the OpenEdition interface.

Termination of Control-O or the CMEM monitor continues. Warnings may be issued the next time Control-O or CMEM is activated.

Corrective Action: Look for previous messages which explain the cause of the failure. Verify successful initialization the next time Control-O or CMEM is activated.

MTO795W OPENEDITION INTERFACE MODULE NOT INSTALLED

Explanation: Control-O or the CMEM monitor could not find the OpenEdition interface module during termination.

During termination Control-O or CMEM detected an environment which supports the OpenEdition interface but could not find the OpenEdition support module which should have been installed during initialization.

Termination of Control-O or the CMEM monitor continues. Warnings may be issued the next time Control-O or CMEM is activated.

Corrective Action: Look for previous messages which explain the cause of the failure. Verify successful initialization the next time Control-O or CMEM is activated.

MTO796W SUBSYSTEM NOT REMOVED FROM OPENEDITION INTERFACE: rsn

Explanation: Control-O or CMEM could not remove its subsystem name from the OpenEdition interface during termination.

If the value of rsn is SUBSYSTEM NOT FOUND, Control-O or CMEM could not find its subsystem name registered with the OpenEdition interface.

If the value of rsn is LOCK CANNOT BE OBTAINED, Control-O or the CMEM monitor could not get the OpenEdition interface lock it needs to remove its name.

Termination of Control-O or the CMEM monitor continues. Warnings may be issued the next time Control-O or CMEM is activated.

Corrective Action: Look for previous messages which explain the cause of the failure. Verify successful initialization the next time Control-O or CMEM is activated.

MTO797E INVALID MODIFY-REFRESH SUBPARAMETERS. VALID PARAMETERS ARE: XCF

Explanation: The user issued the command F Control-O, REFRESH= parm to refresh the Control-O communication definitions, but the value of parm was invalid.

The valid value of the subparameter is XCF.

Refresh of the Control-O communication definition fails.

Corrective Action: Correct and reenter the command.

MTO798E ERROR IN MODIFY-REFRESH PROCESSING

Explanation: An error was detected while attempting to refresh the XCF configuration map of Control-O, which defines the MVS image names with which Control-O can work.

Refresh of the Control-O communication definition by the REFRESH command fails.

Corrective Action: Refer to the earlier accompanying messages in the Control-O JOBLOG or SYSLOG.

Parent Topic

MTO messages