Messages CTWG00 through CTWGxx

This group includes messages for the Control-M for z/OS, Control-M/Assist, Control-M/Links for z/OS, and Control-M/Restart products.

CTWG00I ENTERPRISE/CS MAINFRAME GATEWAY STARTED, RELEASE= rel

Explanation: This information message indicates a normal start of MVS Gateway for Enterprise Controlstation.

Corrective Action: No action is required.

CTWG01I ENTERPRISE/CS MAINFRAME GATEWAY DEBUG LEVEL IS SET TO debugLevel

Explanation: This information message indicates that the Enterprise Controlstation Mainframe Gateway DEBUG level was set by an operator modify command (F).

The TRACE level is set to a new level. Each TRACE level activates the trace option on different components of the Enterprise Controlstation Mainframe Gateway.

Corrective Action: No action is required.

CTWG02E ENTERPRISE/CS MAINFRAME GATEWAY NOT APF-AUTHORIZED

Explanation: The Enterprise Controlstation Mainframe Gateway is not APF-authorized. The CTWGTW module is not in an APF-authorized library or does not have the AC=1 attribute.

The Enterprise Controlstation Mainframe Gateway shuts down.

Corrective Action: Either add the library name in which CTWGTW resides to the IEAAPF00 member in SYS1.PARMLIB, or relink the module with the AC=1 attribute.

CTWG03E INVALID MODIFY PARAMETER. VALID PARAMETERS ARE:

Explanation: An operator modify command (F) passed an erroneous parameter to the Enterprise Controlstation Mainframe Gateway. One or more GTWG25I messages are displayed on the operator console after this message, each containing a valid modify parameter.

The modify command is rejected.

Corrective Action: Enter a valid modify parameter.

CTWG04E BLDL/ATTACH FAILED FOR TASK taskName

Explanation: Initialization of one of the Enterprise Controlstation Mainframe Gateway’s internal tasks failed. The system code indicating the exact reason can be found in the system log.

This may be due to one of the following:

The Enterprise Controlstation Mainframe Gateway shuts down.

Corrective Action: Call your system programmer for assistance. If necessary, increase the Enterprise Controlstation Mainframe Gateway REGION size.

CTWG05E UNRECOVERABLE ERROR ENCOUNTERED

Explanation: An unrecoverable error occurred in the operation of the Enterprise Controlstation Mainframe Gateway. The IOA Log, or the Enterprise Controlstation Mainframe Gateway JES messages file or SYSPRINT file, should contain a message with more details about the error. See also, CTWA01W.

The Enterprise Controlstation Mainframe Gateway shuts down.

Corrective Action: Call your system programmer for assistance. If the problem is not resolved, call BMC Customer Support for assistance.

CTWG06E ONE OF THE SUBTASKS HAS ABENDED

Explanation: One of MVS Gateway for Enterprise Controlstation’s internal subtasks has abended.

MVS Gateway for Enterprise Controlstation shuts down with user abend 0006. A dump of the abending task is included in the SYSABEND output file.

Corrective Action: Call your system programmer for assistance. If the problem is not resolved, contact BMC Customer Support.

CTWG07I SHUT DOWN UPON REQUEST FROM OPERATOR

Explanation: This information message confirms that an operator command (P) was issued, requesting shutdown of MVS Gateway for Enterprise Controlstation. This message is followed by message GTWG20I, indicating completion of the shutdown.

MVS Gateway for Enterprise Controlstation starts to shut down.

Corrective Action: No action is required.

CTWG10E TRACE LEVEL MUST BE A NUMBER BETWEEN 0 AND 255

Explanation: An invalid TRACE level was entered, either in the operator modify command (F) or in the operator start command (S). When activating the Enterprise Controlstation trace facilities, specify a number from 0 through 255, inclusive, for the TRACE level. 0 specifies no tracing.

Corrective Action: Issue the command again with the correct TRACE level. The required TRACE level should be supplied by BMC Customer Support.

CTWG11I SERVICE ID " id " IS {ENABLED | DISABLED}

Explanation: This information message confirms the current enable or disable status of service ID, after the operator has issued an operator modify command (F) that enables or disables it.

Corrective Action: No action is required.

CTWG12E INVALID PARAMETERS (parms) PASSED TO THE ENTERPRISE/CS MAINFRAME GATEWAY

Explanation: One or more parameters which were passed to the Enterprise Controlstation Mainframe Gateway in an operator start command (S) were invalid.

The Enterprise Controlstation Mainframe Gateway shuts down.

Corrective Action: Restart the Enterprise Controlstation Mainframe Gateway with valid parameters.

CTWG13E OPEN OF CONTROL-M ACTIVE JOBS FILE FAILED. DDNAME "DACKPT"

Explanation: Open of the Control-M Active Jobs file failed (the DACKPT DD statement). This may be due to one of the following:

The program stops executing.

Corrective Action: Correct the JCL for the job or started task and rerun or restart it.

CTWG14I ENTERPRISE/CS MAINFRAME GATEWAY subtaskName (id) STARTED

Explanation: This information message indicates that a Control-M NJE subtask started normally.

Corrective Action: No action is required.

CTWG15I ENTERPRISE/CS MAINFRAME GATEWAY subtaskName (id) SHUT DOWN UPON REQUEST FROM MAIN TASK

Explanation: This information message indicates that a Control-M NJE subtask terminated normally.

Corrective Action: No action is required.

CTWG16E OPEN OF CONTROL-M STATISTICS FILE FAILED. DDNAME "DASTAT"

Explanation: The program is unable to open the Control-M Job Execution Statistics file (DD statement DASTAT). Possible causes are:

The program continues executing, but without accessing the Job Execution Statistics file.

Corrective Action: Look for VSAM messages or other system messages. Correct the JCL for the job or started task and rerun or restart it.

CTWG17E FILE ALLOCATED TO DDNAME "DACKPT" IS NOT YOUR CONTROL-M ACTIVE JOBS FILE

Explanation: The data set pointed to by the DACKPT DD statement is not your Control-M Active Jobs file. This is due to one of the following:

The program stops executing.

Corrective Action: Correct the JCL of the job or started task and rerun or restart it.

CTWG19W DUPLICATE processing_parm FOUND IN JOB jobName ORDERID orderId

Explanation: During download of the Control-M Active Jobs file or update of the Active network, a job was encountered that contained a duplicate processing parameter entry.

Only one of the duplicate entries will be downloaded.

Corrective Action: It is advisable to correct the job definition in the mainframe so that it does not contain any duplicate processing parameter entries.

CTWG20I ENTERPRISE/CS MAINFRAME GATEWAY SHUTTING DOWN

Explanation: This information message is issued when the Control-M NJE Gateway shuts down, either as a result of an operator command (P), or due to internal Control-M NJE Gateway events. The Control-M NJE Gateway log, the Control-M NJE Gateway JES messages file, or the SYSPRINT file usually contain additional messages concerning the reason for the shutdown.

The Control-M NJE Gateway shuts down.

Corrective Action: No action is required.

CTWG21S ENTERPRISE/CS MAINFRAME GATEWAY ENDED WITH ERRORS

Explanation: The Enterprise Controlstation Mainframe Gateway ended with an error. The IOA Log, or the Enterprise Controlstation Mainframe Gateway JES messages file or SYSPRINT file, should contain additional messages concerning the specific error.

The Enterprise Controlstation Mainframe Gateway shuts down.

Corrective Action: Check the IOA Log or the system log for the reason. Call your system programmer for assistance if needed. Try to start the Enterprise Controlstation Mainframe Gateway again.

CTWG22W DUPLICATE processing parm FOUND IN JOB jobName TABLE tableName

Explanation: During table download, a job was encountered that contained a duplicate processing parameter entry.

Only one of the duplicate entries will be downloaded.

Corrective Action: It is advisable to correct the job definition in the mainframe so that it does not contain any duplicate processing parameter entries.

CTWG23I CONTROL-M NJE GATEWAY INTERVAL IS SET TO nn SECONDS

Explanation: This information message displays the current NJE Gateway sleeping interval after it is set by an operator Modify command (F).

The NJE Gateway wakes up every nn seconds to check what it must do.

Corrective Action: No action is required.

CTWG24E INTERVAL MUST BE A TWO-DIGIT NUMBER BETWEEN 03 AND 99 SECONDS

Explanation: Invalid Enterprise Controlstation Mainframe Gateway sleeping interval specified in an operator modify command (F). The Enterprise Controlstation Mainframe Gateway sleeping interval must be a 2-digit number from 03 to 99 seconds.

The modify command is rejected.

Corrective Action: Enter a valid sleeping interval.

CTWG25I valid parm

Explanation: This information message accompanies message GTWG03E, which indicates that an invalid modify parameter was specified. This message contains a valid modify parameter. This message may appear more than once. Each occurrence lists another valid modify parameter.

Corrective Action: No action is required.

CTWG26E MAXIMUM "ON" CODES EXCEEDED IN JOB jobName TABLE tableName

Explanation: During Table Download, a job was encountered that contained too many ON codes. There is insufficient space in the internal buffer for the number of ON codes in the job definition.

The table download fails.

Corrective Action: It is advisable to correct the job definition in the mainframe so that it contains fewer ON codes.

CTWG27S INSUFFICIENT STORAGE FOR CONTROL-M APPLICATION SERVER

Explanation: Insufficient storage available for the Control-M Application Server to execute.

The Control-M Application Server shuts down.

Corrective Action: Increase the REGION size parameter for the CTMAS procedure. If it is already REGION=0M, contact BMC Customer Support.

CTWG28E MAXIMUM "ON" CODES EXCEEDED IN JOB jobName ORDERID orderId

Explanation: During download of the Active Jobs file or update of the Active network, a job was encountered that contained too many ON codes. There is insufficient space in the internal buffer for the number of ON codes in the job definition.

Download of the Active Jobs file or update of the Active network will continue, but the specific job will not be downloaded.

Corrective Action: It is advisable to correct the job definition in the mainframe so that it contains fewer ON codes.

CTWG29E CTWGNRL FAILED. TASKID= id FUNCTION= func RC= rc

Explanation: MVS Gateway for Enterprise Controlstation detected an internal error beyond user control. This error message is issued by the CTWGTW program, which is activated as part of MVS Gateway for Enterprise Controlstation.

MVS Gateway for Enterprise Controlstation shuts down.

Corrective Action: Contact BMC Customer Support.

CTWG30E CTWPUT FAILED. TASKID= taskId PUTID= putId RC= rc

Explanation: Control-M NJE Gateway detected an internal error. Internal CTWPUT operation that was issued by PUTID putId, under subtask number taskId, failed with a return code of rc. If rc=20, a GETMAIN failure occurred above the 16M line.

For some errors, Control-M NJE Gateway shuts down. For other errors, operation continues.

Corrective Action: If Control-M NJE Gateway shuts down, contact BMC Customer Support. If rc=20, increase the region size.

CTWG31W YOUR ENTERPRISE/CS MAINFRAME GATEWAY IS ALREADY ACTIVE. QNAME qName

Explanation: Highlighted, unrollable message.

An attempt was made to start an Enterprise Controlstation Mainframe Gateway which was already active. It is impossible to run two Enterprise Controlstation Mainframe Gateways with the same QNAME at the same time.

The newly started Enterprise Controlstation Mainframe Gateway shuts down.

Corrective Action: No action is required.

CTWG32E CONTROL-M RELEASE NOT SUPPORTED (rel)

Explanation: The Enterprise Controlstation Mainframe Gateway was started on a Control-M installation with a release (rel) that is not supported. The Enterprise Controlstation supports Control-M Release 3.0.0 and above.

The Enterprise Controlstation Mainframe Gateway shuts down.

Corrective Action: No action is required.

CTWG33E INCOMPATIBLE GATEWAY VERSIONS. MAINFRAME GATEWAY VERSION mainframe_version. WORKSTATION GATEWAY VERSION workstation_version

Explanation: The version of MVS Gateway for Enterprise Controlstation is not compatible with the Workstation Gateway version. The two gateways should be installed from the same installation version. If only one gateway was upgraded, the link cannot become active.

MVS Gateway for Enterprise Controlstation shuts down.

Corrective Action: Either upgrade the lower version gateway, or restore the upgraded gateway to the previous version.

CTWG34E CONTROL-M APPLICATION SERVER DOES NOT SUPPORT COMPATIBILITY MODE

Explanation: The Control-M compatibility mode in IOAPARM is set to 2 (MODECTM=3). The Control-M application server can work in no compatibility mode (MODECTM=3).

The Control-M application server terminates with a return code of 8.

Corrective Action: Correct the error and try again, or start a Control-M application server from an earlier version.

CTWG41I CURRENT STATE: DOWN, REQUIRED STATE: UP

Explanation: This information message indicates that the Control-M monitor component being monitored by the Control-M/CM Application Server is DOWN, while its desired state is UP.

Corrective Action: Start the Control-M monitor, or change the desired state to DOWN.

CTWG42I CURRENT STATE: UP, REQUIRED STATE: DOWN

Explanation: This information message indicates that the Control-M monitor component being monitored by the Control-M/CM Application Server is UP, while its desired state is DOWN.

Corrective Action: Stop the Control-M monitor, or change the desired state to UP.

CTWG43E CTMCAS CANNOT START, param PARAMETER IS MISSING

Explanation: The Control-M/CM Application Server could not be started, because mandatory parameter param is missing from the CTMPARM member.

The Control-M/CM Application Server shuts down.

Corrective Action: Specify the missing parameters in CTMPARM and then restart the Control-M/CM Application Server.

CTWG51E ENTERPRISE/CS MAINFRAME GATEWAY INTERNAL ERROR. RC= rc

Explanation: An internal error occurred. A call to internal routine ECAPUT failed with return code rc.

The IOA Gateway shuts down.

Corrective Action: Contact your INCONTROL administrator.

Parent Topic

CTW messages