This group includes messages for the Control-M for z/OS, Control-M/Assist, Control-M/Links for z/OS, and Control-M/Restart products.
Explanation: Invalid format of Control- x Installation DAYTIME parameter. DAYTIME is the start time of the Control-M work day in your installation. Valid formats are +hhmm or -hhmm.
For more details see the section that describes installation parameters in the chapter for the appropriate products in the INCONTROL for z/OS Installation Guide.
The requested function terminates.
Corrective Action: Call your system programmer to correct the DAYTIME parameter in the CT xPARM member.
Explanation: The opening of a print file failed.
Possible causes are:
The program stops executing.
Corrective Action: Correct the JCL and submit again.
Explanation: Highlighted, unrollable message.
The DATETYP IOA Installation Parameter is invalid. DATETYP is the type of date format used in the installation. Valid formats are:
For more details refer to the section that describes how to set IOA installation parameters in the IOA chapter of the INCONTROL for z/OS Installation Guide.
The requested function stops.
Corrective Action: Call your system programmer to correct the DATETYP parameter in the IOAPARM member.
Explanation: One of the IOA monitor internal programs detected an IOA resource in use by a TSO user or batch job. This message normally appears a few times a day.
The variables in this message are:
Valid values are:
rname |
Meaning |
---|---|
CNDF |
The IOA Conditions file |
RESF |
The Control-M Resources file |
LOG |
The IOA Log file |
Control-M |
The Control-M New Day procedure |
JES_SSRQ |
A JES subsystem request |
CKPT |
The Control-M Active Jobs file or the Control-D Active Missions file |
The message is displayed on the operator console.
Corrective Action: The user response depends on the circumstances, as follows:
Take appropriate corrective action.
Explanation: Highlighted, unrollable message.
More memory is required for the INCONTROL monitor.
The specified monitor will shut down.
Corrective Action: Increase the REGION size of the specified monitor.
Explanation: Highlighted, unrollable message.
An internal error occurred in the Control-M monitor.
The Control-M monitor abends with the user abend 0008.
Corrective Action: Try to start the Control-M monitor again. In any case, keep the dump and call BMC Customer Support for assistance.