Previous Topic

Next Topic

Book Contents

Book Index

Messages CTW900 through CTW9xx

This group includes messages for the Control-M for z/OS, Control-M/Assist, Control-M/Links for z/OS, and Control-M/Restart products.

CTW912S ERROR IN CONTROL- x INSTALLATION PARAMETERS - INVALID DAYTIME

Explanation: Invalid format of Control- x Installation DAYTIME parameter. DAYTIME is the start time of the Control-M work day in your installation. Valid formats are +hhmm or -hhmm.

For more details see the section that describes installation parameters in the chapter for the appropriate products in the INCONTROL for z/OS Installation Guide.

The requested function terminates.

Corrective Action: Call your system programmer to correct the DAYTIME parameter in the CT xPARM member.

CTW913S OPEN OF DDNAME "SYSPRINT" FAILED

Explanation: The opening of a print file failed.

Possible causes are:

The program stops executing.

Corrective Action: Correct the JCL and submit again.

CTW914S ERROR IN IOA INSTALLATION PARAMETERS - INVALID DATETYP

Explanation: Highlighted, unrollable message.

The DATETYP IOA Installation Parameter is invalid. DATETYP is the type of date format used in the installation. Valid formats are:

For more details refer to the section that describes how to set IOA installation parameters in the IOA chapter of the INCONTROL for z/OS Installation Guide.

The requested function stops.

Corrective Action: Call your system programmer to correct the DATETYP parameter in the IOAPARM member.

CTW916W PROGRAM pgm WAITING FOR resourceName

Explanation: One of the IOA monitor internal programs detected an IOA resource in use by a TSO user or batch job. This message normally appears a few times a day.

The variables in this message are:

Valid values are:

rname

Meaning

CNDF

The IOA Conditions file

RESF

The Control-M Resources file

LOG

The IOA Log file

Control-M

The Control-M New Day procedure

JES_SSRQ

A JES subsystem request

CKPT

The Control-M Active Jobs file or the Control-D Active Missions file

The message is displayed on the operator console.

Corrective Action: The user response depends on the circumstances, as follows:

Take appropriate corrective action.

CTW918S INSUFFICIENT MEMORY TO RUN CONTROL- x

Explanation: Highlighted, unrollable message.

More memory is required for the INCONTROL monitor.

The specified monitor will shut down.

Corrective Action: Increase the REGION size of the specified monitor.

CTW919S INTERNAL ERROR IN CONTROL-M MONITOR

Explanation: Highlighted, unrollable message.

An internal error occurred in the Control-M monitor.

The Control-M monitor abends with the user abend 0008.

Corrective Action: Try to start the Control-M monitor again. In any case, keep the dump and call BMC Customer Support for assistance.

Parent Topic

CTW messages