This group includes messages for the Control-D, Control-D/Image, and Control-D/Page on Demand products.
Explanation: A line command (option) was entered in an Index Window on a line that does not contain an index name. The Index Window displays a list of indexes whose values can be used to retrieve a report or section of a report. Options S (Select) and Q (Quick Index) can only be used to select an existing index.
Corrective Action: Use the S or Q line command to select a filled-in index name, or exit the Index Window using the PF04 or PF16 key.
Explanation: Option X to list a report indexes in the Index Window was specified in the Active Report List screen but the selected report has no index.
Corrective Action: Define one or more indexes with DO INDEX statements in the Report Decollation Mission if this report should be indexed.
Explanation: This information message indicates that an attempt was made to display more than nine indexes. The screen on which indexes are displayed has room for nine indexes.
Only the first nine indexes are displayed.
Corrective Action: Redefine the Report Decollation Mission to specify no more than nine indexes for this report.
Explanation: A character other than S, Q or blank was entered in an Index Window Option field. S selects an index and displays its Values of Index Panel. Q displays the Quick Access Panel for the specified index.
The specified character is ignored. The system waits for a valid option or command.
Corrective Action: Specify option S or Q, or press PF03 or PF04 to redisplay the Active User Report List.
Explanation: The specified index has no values in the specified user report. An error probably occurred in:
Corrective Action: Check the Decollation Mission Definition for this report. Be sure the user-recipient and index are properly specified.
Explanation: The VALUE field in the User Reports Entry Panel began with a single (’) or double (") quote but did not end with the same type of quote.
The specified value is ignored.
Corrective Action: Specify a valid index value in the VALUE field or leave the field empty.
Explanation: Control-D or V failed to dynamically allocate an index file.
The index file is not allocated.
Corrective Action: See the IBM manual MVS Programming: Authorized Assembler Services Guide for a description of the reason code received. If you cannot resolve the problem, record the rsn and contact BMC Customer Support.
Explanation: An invalid option was specified in the OPTION field of the User Reports Entry Panel.
The only valid options are:
Corrective Action: Specify a valid option.
Explanation: An invalid option was specified in the SHOW MIGRATED field of the User Reports Entry Panel.
The only valid options are:
Corrective Action: Specify a valid option. Blank is not valid.
Explanation: An index file could not be opened. It was probably deleted or uncataloged.
Corrective Action: Check the IOA Log file for a message indicating the report name and the name of the index file that could not be opened. Recreate the index which could not be opened by decollating the report again.
Explanation: This information message indicates that more than one index satisfies the specified index mask or more than one value satisfies the specified value prefix.
The entire report will be viewed or printed unless the User Action described below is taken.
Corrective Action: Use the Index Window to specify a unique index or use the Values of Index Panel to specify a unique value before viewing or printing the report.
Explanation: This information message indicates that the specified value does not exist in the specified index.
The entire report is viewed or printed unless a unique existing value is specified before viewing or printing.
Corrective Action: Specify the desired index and value in the User Reports Entry Panel. Use the Index Window to determine if the desired index exists. Use the Values of Index Panel to determine if the desired value exists.
Explanation: Option E is not supported for migrated reports.
Corrective Action: Use option V to view the migrated report and PF04 to edit its ruler.
Explanation: There was an attempt to change the Display Type by means of the DISPLAY command. However, while the BYPASS PANEL parameter is set to Q, only Display Type Q (Quick Access) is valid and no other Display Type is available.
Setting the BYPASS PANEL parameter in the User Reports Entry Panel to Q enables users to work directly with the Quick Access Panel. If more than one report matches selection criteria while the BYPASS PANEL parameter is set to Q, the matching reports are listed so users can specify which report to display in the Quick Access Panels. While this list is displayed, only Display Type Q and option Q are valid.
Corrective Action: To change the Display Type, use the RETURN command to access the User Reports Entry Panel. Change the value of the BYPASS PANEL parameter to Y or N. Specify the desired Display Type in the DISPLAY TYPE parameter in the User Reports Entry Panel or, after pressing Enter to display the User Reports List, use the DISPLAY command.
Explanation: An invalid date parameter was specified in the User Report List Entry Panel. The TO DATE field must be blank when specifying FROM DATE=LAST.
Corrective Action: Correct the date parameter.
Explanation: An invalid combination of values was specified in the User Report List Entry Panel. The USER field must not be blank when specifying FROM DATE=LAST.
Corrective Action: Specify a valid user name in the USER field or do not specify LAST in the FROM DATE field.
Explanation: The PREV command was entered, or the PF10 or PF22 key was pressed in the Quick Access Panel to display a previous index for a report, but no previous index exists.
The current index-report combination remains displayed in the Quick Access Panel.
Corrective Action: Use the NEXT command or PF11 or PF23 key to display the next index, if any exists, for the report.
Explanation: The NEXT command was entered, or the PF11 or PF23 key was pressed in the Quick Access Panel to display the next index for a report, but no next index exists.
The current index-report combination remains displayed in the Quick Access Panel.
Corrective Action: Use the PREV command, or press the PF10 or PF22 key to display the previous index, if any exists, for the report.
Explanation: Display of Quick Access Panels was requested for a report that has no indexes. Quick Access Panels cannot be displayed for a report that has no indexes.
Quick Access Panels are not displayed.
Corrective Action: Determine why the report has no index. If necessary, modify and rerun the Decollation Mission to create one or more indexes for the report.
Explanation: The index value entered in the Quick Access Panel does not exist in the current index. The user attempted to print a report, or section of a report, based on an index value specified in the Quick Access Panel. The specified value does not exist in the current index for the report.
The report is not printed.
Corrective Action: Display the Values of Index Panel for the specified report and index to list existing index values.
Explanation: DISPLAY Q was entered on the command line of an Active User Reports List. Display Type Q facilitates the display of data about a report in the Quick Access Panels. Display Type Q is only available when the BYPASS PANEL parameter in the User Reports Entry Panel is set to Q. Display Type Q cannot be implemented by means of the DISPLAY command.
Corrective Action: Use option Q in any display type of the Active User Reports List to access the Quick Access Facility. The display type does not need to be changed to Q in order to use option Q.
Explanation: Due to an internal error in routine routineName, a cache request could not be satisfied. The return code from routine routineName was rc. The View option (V) was specified. Routine routine was called by the View function.
Possible causes and return codes by routine name:
The report is not displayed or only partially displayed.
Corrective Action: Use the information above to determine what is wrong with the cache request mechanism. If the error cannot be resolved, record the error message and contact BMC Customer Support.
Explanation: The IOA Archive Server was either terminated or not started.
The cache request is not performed.
Corrective Action: Ask the operator to start the IOA Archive Server.
Explanation: The media to which the requested report migrated is not active in the IOA Archive Server. The required media was terminated or not started.
The cache request is not performed.
Corrective Action: Ask the operator to activate the required media in the IOA Archive Server.
Explanation: The requested report was not found in the catalog. The IOA Archive Server searched the catalog for the requested migrated report but did not find it.
The cache request is not performed.
Corrective Action: Contact your INCONTROL administrator to find out what happened to the required data set.
Explanation: The requested report migrated to a volume that has been manually deleted from the OSS database.
The cache request is not performed.
Corrective Action: Contact your OSS operator to find out what happened to the required volume.
Explanation: The requested report migrated to a volume that resides on a platter that has been exported or manually deleted from the OSS database.
The cache request is not performed.
Corrective Action: Contact your OSS operator to find out what happened to the required platter.
Explanation: The media to which the requested report migrated has no currently active device in the IOA Archive Server. The devices of the required media were terminated or not started.
The cache request is not performed.
Corrective Action: Ask the operator to activate at least one device of the required media in the IOA Archive Server.
Explanation: The CTVX001 exit, could not retrieve an index value from a non-Control-V index file.
The system stops.
Corrective Action: Contact BMC Customer Support.
Explanation: Options R and C are not supported for migrated reports.
Corrective Action: Specify a valid option.
Explanation: The IOA Archive Server could not allocate a device to retrieve a migrated report. See messages DVT191E or IOA191E and DVT192E or IOA192E in the IOA Log file for the error code and information about the failed allocation.
The cache request is not performed.
Corrective Action: Correct the problem that caused the allocation to fail, and retry.
Explanation: The operator did not mount a volume requested by the IOA Archive Server. The requested volume could not be found or the operator did not mount the volume for some other reason.
The cache request is not performed.
Corrective Action: Contact the operator to determine why the requested volume was not mounted.
Explanation: Due to an internal error in the cache mechanism, a cache request was not performed. Return code rc was produced as a result, as shown below.
rc |
Explanation |
---|---|
20 |
Media error in adding request to chain. |
24 |
Media error in GETMAIN for TVL. |
28 |
Media error handling multivolume file. |
36 |
Media error: File resides on more than five volumes. |
60 |
Media error: An RQC was queued without RBAs. |
64 |
OASDVT error: An RQC was queued with a zeroed RBA. |
68 |
Media error during deallocation. See messages DVT191E or IOA191E and DVT192E or IOA192E in the IOA Log file for the error code and more information. |
76 |
Media error: Open failed. |
80 |
Media error: Task abended during open. See message DVT194E or IOA194E in the IOA Log file for the abend code. |
84 |
Media error: I/O error on device. See message DVT193E or IOA193E in the IOA Log file for the input or output error description. |
92 |
IOASDVT error while reading the descriptor block of a migrated CDAM file. |
96 |
IOASDVT error while acquiring storage for a migrated CDAM descriptor block. See message DVT180S in the IOA Log file for more information. |
100 |
IOASDVT error while reading the first block from a migrated CDAM file. |
104 |
IOASDVT error while acquiring storage for the first block of a migrated CDAM file. See message DVT180S in the IOA Log file for more information. |
108 |
IOASDVT error while acquiring storage for cache. See message DVT180S in the IOA Log file for more information. |
112 |
IOASDVT error: Extent number in RBA is out of range. |
116 |
Error while translating RBA to BBB. |
120 |
IOASDVT error: block number is out-of-range. |
124 |
Error while translating BBB to RBA. |
128 |
IOASDVT error while issuing ENQ to test user existence. See message DVT181E or IOA181E in the IOA Log file for more information. |
132 |
IOASDVT error: Task abended during cache request processing. |
140 |
Media error: Assigned device could not be allocated because it is unavailable. See messages DVT191E or IOA191E and DVT192E or IOA192E in the IOA Log file for the error code and more information. |
The cache request is not performed.
Corrective Action: See the IOA Log file for messages regarding the event. Use the return code to determine what caused the IOA Archive server cache mechanism to fail. If the error cannot be resolved, contact BMC Customer Support.
Explanation: This message indicates that more than one index satisfies the specified index mask, or more than one value satisfies the specified prefix value.
The report is not printed.
Corrective Action: To print a specific portion of the report use the Index window to specify a unique index, or use the Values of Index panel to specify a unique value.
Explanation: This message indicates that the specified value does not exist in the specified index.
The report is not printed.
Corrective Action: Use the Index window to determine whether or not the required index exists. Use the Values of Index panel to determine whether or not the required value exists. Specify the required index and value for the print request.
Explanation: This information message indicates that there are no lower level indexes for this index.
Corrective Action: No action is required.
Explanation: This information message indicates that no values of the specified index appear in the user’s report.
Corrective Action: No action is required.
Explanation: A migrated report could not be accessed because the media to which it was migrated was not found. The $SYSDATA entry that corresponds to this migrated report specifies a migrated media which does not appear in IOASPRM.
The migrated report is not accessed.
Corrective Action: Have your INCONTROL administrator correct IOASPRM to reference the migrated media that appears in the $SYSDATA entry.
Explanation: An internal error occurred during the execution of a FREEMAIN macro. This error occurred during the execution of the database conversion utility. See CVIGC5S.
The database conversion utility terminates with an error. The conversion of the VSAM file to an IOA Access Method file is not completed.
Corrective Action: Contact BMC Customer Support.