Previous Topic

Next Topic

Book Contents

Book Index

Messages CTD700 through CTD7xx

This group includes messages for the Control-D, Control-D/Image, and Control-D/Page on Demand products.

CTD701E PLEASE FILL IN REPORT/JOB NAME OR OMIT CATEGORY

Explanation: A category name is specified, but the report or job name is missing. A report or job must be specified as well as a category name.

Corrective Action: Either fill in a report or job name or omit the category to get a list of reports or jobs in the library.

CTD702E CTLG N CAN NOT BE SPECIFIED FOR THIS MEDIA TYPE

Explanation: The CTLG subparameter is specified as N (do not catalog the migrated files) for a medium type that is not CART. This option can be used only for a cartridge type specified as CART in the IOASPRM member.

Corrective Action: Specify Y or blank in the CTLG subparameter.

CTD710E JOBID CAN BE JOBnum TSUnum STCnum * OR BLANK

Explanation: There is an invalid value in a decollation mission JOBID field.

The JOBID field in a Decollation mission can take one of the following values only:

where num is a 5-digit value

Corrective Action: Specify a JOBID in one of the above formats, or leave the field empty.

CTD711E ON CLASS IS VALID ONLY WITH IN QUEUE=Y/E OR WITH JOBID

Explanation: ON CLASS is specified in the Control-D Report Definition Screen (screen R) without Y or E in the WHEN IN QUEUE field, or without specifying the JOBID. To define an ON CLASS in a report definition, the WHEN IN QUEUE field must be either Y or E, or the job ID must be specified in the JOBID field.

Corrective Action: Specify Y or E in the WHEN IN QUEUE field, or the job ID in the JOBID field, or delete the ON CLASS definition.

CTD712E VALID VALUES FOR IN QUEUE ARE "Y" "N" "E" OR BLANK

Explanation: There is an invalid value in the WHEN IN QUEUE Decollation mission field. Valid values for WHEN IN QUEUE field in a decollation mission are Y, N, E or BLANK only.

Corrective Action: Specify either Y, N, or E in the WHEN IN QUEUE field, or leave it empty.

CTD713E JOBID CAN BE JOBnum TSUnum STCnum OR BLANK

Explanation: There is an invalid value in a decollation mission JOBID field. The JOBID field in Decollation mission can take one of the following values only:

where num is a 5-digit value.

Corrective Action: Specify a JOBID in one of the above formats, or leave the field empty.

CTD714E UNTIL LINE SHOULD BE BLANK WHEN FROM LINE IS *

Explanation: There is an invalid value in the WHEN TO LINE field in a decollation mission. If an asterisk is specified in the second WHEN FROM LINE field, the WHEN TO LINE field must be blank.

Corrective Action: Clear the WHEN TO LINE field with a blank, or change the value of the WHEN FROM LINE field.

CTD715E MASK IN JOBNAME IS ALLOWED ONLY FOR GENERIC DECOLLATIONS

Explanation: A mask character in the JOBNAME parameter for a decollation mission is not generic. In a non-generic decollation mission, the JOBNAME parameter must be unique and cannot contain mask characters.

Corrective Action: Either make the decollation generic, or specify a unique value in the JOBNAME parameter.

CTD716E FOR RECORD LEVEL INDEX, MASK MUST HAVE LINE RANGE AND INDEX LINE +/-

Explanation: The DO INDEX statement is invalid. A record level index was specified without a line range for the mandatory mask, or without an index line location defined as a +/- offset from the location of the line containing the mandatory mask.

If a DO INDEX statement contains the REC parameter set to Y or C, it must also contain both of the following:

The decollation mission is not saved or updated.

Corrective Action: Specify a page-level index (set REC to N), or specify a mask with a mask line range and an index value location which is defined as a + or - offset from the mask line.

CTD719E FOR JOBNAME_DDNAMES INDEX MIGRATION MISSION MUST BE "JOBARC"

Explanation: A migration mission name other than JOBARC was specified in a JOB ARCHIVE decollation mission definition. Decollation definitions for the JOB ARCHIVE utility must include both the special index JOBNAME_DDNAMES and the migration mission name JOBARC.

The cursor stays in the field until the correct migration mission name is specified.

Corrective Action: Change the migration mission name to JOBARC.

CTD71AE MASK mparm CONFLICTS WITH INDEX iparm +/-

Explanation: There is a conflict between the values specified for the following parameters, because one of these values is invalid:

For more information on these parameters, see the Control-D and Control-V User Guide.

The variables in this message are:

The system waits for the parameter values to be corrected.

Corrective Action: Correct the parameter values.

CTD725I TOP OF CATEGORIES LIST

Explanation: This information message indicates that a user attempted to jump to the previous category (using PF10) but the current category is the first category in the member.

Corrective Action: No action is required.

CTD726I BOTTOM OF CATEGORIES LIST

Explanation: This information message indicates that a user attempted to jump to the previous category (using PF11) but the current category is the last category in the member.

Corrective Action: No action is required.

CTD751E PLEASE FILL IN MISSION NAME OR OMIT CATEGORY

Explanation: Category name specified, but mission name missing. A mission name must be defined.

Corrective Action: Either fill in mission name or omit category name to get a list of missions in the library.

CTD769E VALID MISSION TYPE IS PRT/BKP/RST

Explanation: An invalid mission type was entered.

Valid mission types:

Corrective Action: Correct the mission type field.

CTD770E MISSION TYPE MUST BE SPECIFIED WHEN ENTERING A NEW MISSION

Explanation: Missing the mission type field on the Mission Definition screen. The mission type (PRT, BKP or RST) must be entered when defining a new mission.

Corrective Action: Enter the appropriate mission type.

CTD770S OPEN OF CONTROL-D COMMUNICATION FILE FAILED

Explanation: The CTDFRCOM utility, which is used to allocate and format the Control-D Communication file, could not open the file.

Possible causes are:

The utility stops executing with a condition code of 08.

Corrective Action: Correct the JCL and rerun the job.

CTD771I FORMATTING OF CONTROL-D COMMUNICATION FILE STARTED

Explanation: This information message indicates that the Control-D Communication file is currently being formatted.

Corrective Action: No action is required.

CTD772I FORMATTING OF CONTROL-D COMMUNICATION FILE ENDED

Explanation: This information message indicates that the formatting of Control-D Communication file by the CTDFRCOM utility ended.

Corrective Action: No action is required.

CTD773S FORMATTING OF CONTROL-D COMMUNICATION FILE - WRITE I/O ERROR

Explanation: An I/O error occurred during formatting of the Control-D Communication file. This may occur when there is incompatibility between the definition of the Communication file in the Installation Parameters (COMSIZE in CTDPARM) and the JCL SPACE or DCB parameters.

The utility stops executing with a condition code of 08.

Corrective Action: Correct either the JCL or the Installation Parameters.

CTD774S CONTROL-D COMMUNICATION FILE WAS NOT BUILT

Explanation: Due to a problem described by other messages, the Control-D communication file was not built. The CTDFRCOM utility stops executing with a condition code of 08.

Corrective Action: Examine the contents of the system log for additional messages that may clarify the cause of the error. If the CTD913S message is issued, follow the explanation contained in the CTD913S message. If this does not solve the problem, record all related information, including the contents of the CTD913S message, and contact BMC Customer Support.

CTD775I monName CONTROL-D PRINTERS CONTROL-MONITOR STARTED

Explanation: This information message indicates that the monName Control-D Printers Control monitor started.

Corrective Action: No action is required.

CTD776E monName CONTROL-D PRINTERS CONTROL-MONITOR ALREADY ACTIVE

Explanation: Highlighted, unrollable message.

Someone tried to start the monName Control-D Printers Control monitor, which is already active. The Control-D Printers Control monitor is automatically activated from the Control-D monitor. It should not be activated manually.

The monName Control-D Printers Control monitor will shut down.

Corrective Action: No action is required.

CTD777S monName CONTROL-D PRINTERS CONTROL-MONITOR ENDED WITH ERRORS

Explanation: Highlighted, unrollable message.

The monName Control-D Printers Control monitor ended with errors. The IOA Log should contain additional messages concerning each specific error.

The monName Control-D Printers Control monitor and the Control-D monitor will shut down.

Corrective Action: Check the IOA Log and the system log for the reason. Call the system programmer for assistance if needed. Try to start the Control-D monitor again as soon as possible.

CTD778I monName ALL MODIFY/STOP COMMANDS MUST BE ISSUED BY CONTROL-D MAIN MONITOR ONLY

Explanation: This information message indicates that the user tried to issue a MODIFY or STOP command to either the Control-D Printers Control monitor or to a Control-D secondary monitor. A MODIFY or STOP command to the Control-D Printers Control monitor or a Control-D secondary monitor can only be issued by the Control-D primary monitor.

The MODIFY or STOP command is ignored.

Corrective Action: No action is required.

CTD779I monName CONTROL-D PRINTERS CONTROL-MONITOR ENDED

Explanation: Highlighted, unrollable message.

This information message is the general message which is issued when the Control-D Printers Control monitor ends.

Corrective Action: In this message, monName is the name of the Printers Control monitor that has ended.

CTD781E FIELD MUST BE NUMERIC AND IN RANGE OF 1-255

Explanation: An invalid value has been specified in the INTERVAL parameter. The INTERVAL parameter must be numeric, and must contain three digits in the range from 000 through 254.

Corrective Action: Correct the INTERVAL parameter.

CTD782E INVALID PRINTER NAME. YOU CAN USE ONLY NAMES DEFINED TO CONTROL-D

Explanation: An invalid printer name has been specified in the PRINTER parameter of the Printing Mission Definition screen. The printer name specified must be defined in the Control-D Installation Parameters.

Corrective Action: Correct the PRINTER parameter.

CTD783E PLEASE FILL IN THE PRINTER NAME

Explanation: Missing the PRINTER parameter in the Printing Mission Definition screen. The PRINTER parameter is obligatory if the DEST parameter is specified.

Corrective Action: Specify the printer name to be used for printing the bundle.

CTD784E FORM NAME MUST BE SPECIFIED FOR REQUEST

Explanation: Missing the FORM parameter in the Printing Mission Definition screen. The FORM parameter is required if the REQUEST parameter is specified.

Corrective Action: Specify the form number or name to be used in printing the bundle.

CTD785E PLEASE FILL IN THE REQUEST

Explanation: Missing the REQUEST parameter in the Printing Mission Definition screen. The REQUEST parameter is obligatory if the FORM parameter has been specified.

Corrective Action: Specify the REQUEST to be used in printing the bundle.

CTD788E PLEASE FILL IN THE PRINTING MISSION NAME

Explanation: The MISSION NAME parameter on the Printing Mission Definition screen has not been specified. The MISSION NAME parameter is obligatory.

Corrective Action: Specify the Printing Mission name.

CTD789E INVALID FORMAT OF SORT PARAMETERS

Explanation: The format of the SORT SEQ parameter of the Printing Mission Definition screen is invalid. Sort sequence numbers (1-9) must be separated by commas. For details, see the SORT parameter in the Control-D and Control-V User Guide.

Corrective Action: Correct the SORT SEQ parameter.

CTD790E INVALID SORT SEQUENCE NUMBER

Explanation: The sort sequence number in the SORT parameter of the Printing Mission Definition screen is invalid. Valid sort sequence numbers are from 1 through 9. For details, see the SORT parameter in the Control-D and Control-V User Guide.

Corrective Action: Correct the SORT SEQ parameter.

CTD791E DUPLICATE SORT SEQUENCE NUMBER

Explanation: The same sort sequence number was entered twice in the SORT parameter of the Printing Mission Definition screen. Each sort sequence number must be used only once.

Corrective Action: Correct the SORT SEQ parameter.

CTD795E SKELETON MEMBER NAME MUST BE FILLED IN WHEN BATCH=Y

Explanation: A value of Y was entered in the BATCH parameter, but the name of the skeleton member was not specified. When defining a batch print mission, you must specify the skeleton member name.

Corrective Action: Specify the skeleton member name or change the batch parameter to N.

CTD796E SKELETON MEMBER NAME MUST BE BLANK WHEN BATCH=N

Explanation: The skeleton member name was specified, but the BATCH parameter was specified as N. The skeleton member name is valid only when the BATCH parameter is Y

Corrective Action: Erase the skeleton member name or change the BATCH parameter to Y.

CTD797E FREE FIELD CAN BE "CLOSE" OR "END" ONLY

Explanation: An invalid value was specified in the FREE field.

Valid values for the FREE field are:

Corrective Action: Specify either CLOSE or END in the FREE field.

CTD798E FREE FIELD CANNOT BE "END" WHEN BATCH=N

Explanation: END was specified in the FREE field, but the BATCH parameter was N. END is valid in the FREE parameter for batch print missions only. That is, BATCH must be set to Y.

Corrective Action: Change the value of the FREE parameter to CLOSE, or change the value of the BATCH parameter to N.

CTD79AE "MONITOR" FIELD SHOULD BE BLANK OR NUMERIC (1 - 9)

Explanation: An invalid value was specified in the MONITOR parameter of the Printing Mission Definition.

The MONITOR Printing Mission Definition parameter specifies which Control-D Printing monitor address space processes the Printing Mission. The MONITOR parameter can be blank to allow Control-D or Control-V to automatically select the next available Printing monitor, or it can be a number from 1 through 9 to specify the Printing monitor that should process the Printing Mission.

The Printing Mission Definition is not created or saved until a valid value is entered for the MONITOR parameter.

Corrective Action: Enter a number from 1 to 9 in the field for the MONITOR parameter or leave the field blank, then save the Printing Mission Definition.

CTD79CI FORMATTING OF CONTROL-D PAGE COUNTER FILE ENDED

Explanation: This information message indicates that the Page Counter file was formatted successfully by the CTDFRPGC utility.

The CTDFRPGC utility terminates with a return code of 0.

Corrective Action: No action is required.

CTD79DS CONTROL-D PAGE COUNTER FILE WAS NOT BUILT

Explanation: The Page Counter file was not formatted by the CTDFRPGC utility because an error was encountered.

The CTDFRPGC utility terminates with a return code of 8.

Corrective Action: For an explanation of the problem, see the previously issued message (CTM910S or CTM913S). Correct the problem and rerun the utility.

CTD79ES OPEN OF CONTROL-D PAGE COUNTER FILE FAILED

Explanation: The CTDFRPGC utility could not open the Page Counter file for formatting.

The Page Counter file is not formatted. The CTDFRPGC utility terminates with a return code of 8.

Corrective Action: Check the system log output of the job that executed the CTDFRPGC utility for messages associated with the open error. Correct the problem and rerun the utility.

CTD79FS FORMATTING OF CONTROL-D PAGE COUNTER FILE - WRITE I/O ERROR

Explanation: The CTDFRPGC utility could not write a record to the Page Counter file during format processing.

The Page Counter file is not formatted. The CTDFRPGC utility terminates with a return code of 8.

Corrective Action: Check the system log output of the job that executed the CTDFRPGC utility for messages associated with the open error. Correct the problem and rerun the utility.

CTD7A0S PAGE COUNTER FILE FULL. PAGE COUNTING TERMINATES

Explanation: An attempt was made to add a record to the Page Counter file during decollation processing, but no space remains.

Processing of the Page Counter file terminates. The decollation process continues.

Corrective Action: Ignore this message if Page Counter file processing is not needed because the ON PAGE parameter is not specified in any Printing Mission Definition. If Page Counter file processing is needed, stop the Control-D Decollation monitor, delete the Page Counter file (CTD PGC), and use job CTDFRPGC to format a new CTD PGC file with a larger PGCSIZE value. Then restart the Control-D Decollation monitor.

CTD7A1I DDCARD "DAPGC" MISSING. PAGE COUNTING TERMINATES

Explanation: This information message indicates that the DAPGC DD statement was not defined in the Control-D Decollation monitor JCL. The Control-D Decollation monitor could not initialize Page Counter file processing because the Page Counter file is not referenced by the DAPGC DD statement.

The Control-D Decollation and Printing monitors continue normal execution but Page Counter file processing is disabled.

Corrective Action: Ignore this message if Page Counter file processing is not needed because the ON PAGE parameter is not specified in any Printing Mission Definition. If Page Counter file processing is needed, stop the Control-D Decollation monitor, add the DAPGC DD statement to the monitor JCL, then restart the Control-D Decollation monitor.

CTD7A2S INTERNAL ERROR IN FUNCTION func. PAGE COUNTING TERMINATES

Explanation: The Control-D Decollation monitor encountered an internal error during Page Counter file processing. The following are possible causes of the problem:

The Control-D Decollation and Printing monitors continue normal execution but Page Counter file processing is disabled.

Corrective Action: Ignore this message if Page Counter file processing is not needed because the ON PAGE parameter is not specified in any Printing Mission Definition. If Page Counter file processing is needed, stop the Control-D Decollation monitor, delete the Page Counter file (CTD PGC), and use job CTDFRPGC to format a new CTD PGC file with a larger PGCSIZE value. Then restart the Control-D Decollation monitor. If this does not restore Page Counting, prepare the relevant IOA Log file and the system log message output, and contact BMC Customer Support.

Parent Topic

CTD messages