Previous Topic

Next Topic

Book Contents

Book Index

Table layout

The WLMSCTBL table contains several fields, some of them optional, laid out in fixed columns. The following table outlines the uses for each column:

Table 118 WLMSCTBL table

Column Number

Definition

Comment

1

comment indicator (*)

 

2

job name mask

up to 8 characters

11

application name mask

up to 20 characters

32

from time

in HHMM format

37

to time

in HHMM format

42

Job-Init service class

up to 8 characters

51

AftDueIn service class

up to 8 characters

60

AfDueOut service class

up to 8 characters

The following code shows an example of some of the entries in the WLMSCSAM sample table:

*0        1                    3    3    4        5        6

*2        1                    2    7    2        1        0

*!        !                    !    !    !        !        !

*!        !                    !    !    !        !        !

*V        V                    V    V    V        V        V

 K15JOBA  TESTAPPLICATION      2200 0200 STANDARD QUICK    QUICKER

 N50*                          0000 2359 QUICK    QUICKER  QUICKEST

          EMERGENCYAPPL        0000 2359 QUICKEST QUICKEST QUICKEST

 STAMJOB                       1700 2000 STANDARD                 

 STAMJOB                       2200 0200 QUICK                    

 *        PROD*                0000 2359 STANDARD QUICKER  QUICKEST

Parent Topic

WLMSCTBL table