The following table describes the EM Servers tab parameters when defining a new account in Control-M Web Services API.
Parameter |
Definition |
|---|---|
EM Version |
Defines the specific version of Control-M/EM where this account connects. |
EM Host |
Defines the host name of Control-M/EM Corba Naming Service. |
EM Port |
Defines the port number of Control-M/EM Corba Naming Service. |
SSL |
Enables SSL security between Control-M Web Services API and Control-M. |
Global Alert Server name |
Defines the logical name of the GAS server in the above EM Host Name. NOTE: Relevant only for Control-M/EM version 7.0.00 and below. |
GUI Server name |
Defines the logical name of the GUI server in the above EM Host Name. |
Automatic Sign In |
When selected, Control-M Web Services API automatically registers itself in Control-M/EM using the supplied user and password. Otherwise, each request requires you to include a user token. (To obtain a user token, you must send a register request. For more information see Request and Response Parameters in Control-M API). |
EM User |
Defines the name of the Control-M/EM user. |
EM Password |
Defines the name of the Control-M/EM user password. |
EM connection retries |
Defines the number of times reconnection should be attempted. |
Time between retries |
Defines the time between reconnection attempts in seconds. |