Control-M Servers Communication status

The following table describes the columns in the Communication Status window:

Column

Description

Control-M Server

When the gateway is restarted, Control-M/EM attempts to communicate with the Control-M/Server.

Enable

Determines whether Control-M/Server is enabled.

Gateway

Control-M/EM gateway connection to the Control-M/Server.

Communication

Communication route between the Gateway and the Control-M/Server.

Synchronized

Synchronizes the active environment with the Active Jobs file in the Control-M/Server.

Network Status

Determines the status of communication between Control-M/EM and the Control-M/Server.

Folder Sync

Determines whether Folders are synchronized with Control-M/Server.

Calendar Sync

Determines whether Calendars are synchronized with Control-M/Server.

Workload Policies

Determines whether Workload Policies are synchronized with Control-M/Server.

Platform

Distributed.Determines whether the Control-M/Server is installed on a distributed or z/OS operating system.

If your operating system is UNIX or Windows select Distributed.

Version

Determines the version number of the Control-M/Server.

Description

Provides a description of the Control-M/Server.

Contact

Defines the name of the contact person who is responsible for Control-M/Server maintenance.

Protocol

Determines which protocol Control-M/Server uses to communicate with Control-M/EM.

Host

Defines the name of Control-M/Server host.

Control-M/EM Port

Defines the TCP/IP port number that Control-M/Server uses to connect to Control-M/EM.

Start Day

Determines the first day of the business week.

The settings on the Control-M/Server computer must match these settings.

NOTE: This parameter is only enabled if the Control-M/Server is set to Un-Managed.

New Day Time

Determines the time of day that the New Day procedure is performed on the Control-M/Server.

The settings on the Control-M/Server computer must match these settings.

NOTE: This parameter is only enabled if the Control-M/Server is set to Un-Managed.

Daylight Savings Time

Determines the following:

  • Determines whether the Control-M/Server will schedule jobs based on Daylight Savings Time and when it starts and ends
  • Determine how to show forecasts during times when Daylight Savings Time (DST) is active and inactive
  • Determines whether or not to consider which ODAT is used during the time when the New Day occurs and after the time that DST occurs.

NOTE: This parameter is only enabled if the Control-M/Server is set to Un-Managed.

Upper Case

Determines whether to restrict user input to upper case letters only in job attributes.

If you select this option, you cannot change it without fixing all the job attributes.

Enable

Determines whether the Control-M/Server is enabled.

Code

Defines a unique 3-character code (such as 999 or NYC) that Control-M/EM uses to identify each Control-M/Server.

Parent Topic

Communication management