This procedure describes how to install Control-M/EM on UNIX. You can install with the default settings, or choose the custom installation to select the database server, database names, usernames, hostnames, and port settings. If you want to install multiple instances of Control-M/EM on several computers using the same configuration, use the automatic installation, as described in this procedure.
NOTE: You need to install the Control-M client on a Windows computer.
NOTE: The default installation is interactive and uses a GUI display. XServer must be running and configured using the DISPLAY environment variable. If you do not have XServer available, BMC recommends that you continue with the console installation or perform an automatic installation.
Before You Begin
Ensure that you have met the following requirements:
To install Control-M/EM on UNIX:
<source_path>/setup.sh
A confirmation message appears.
<source_path>/Setup_files/components/em/setup.sh -silent <xml_path>/<filename.xml>
The installation log can be found at the following location:
<$HOME>/BMCINSTALL/log/BMC_Control-M_Enterprise_Manager_<date-time>.log
After you have installed Control-M/EM, you need to run a script that removes the Log4j v2 vulnerability, as described in 000391322.