The following table describes Restart Job parameters for Control-M for z/OS Jobs. To define Restart Job parameters, see Restarting a job.
Field |
Description |
---|---|
From Step/Proc |
Determines the Job restart point of the pgmstep and procstep steps. |
To Step/Proc |
Determines the Job restart end point of the pgmstep and procstep steps. If a from step/proc value is defined, and the To step/proc field is blank, the Job reruns up to and including the last step. |
Recapture Abend Codes |
Determines whether to save the Abend codes from the original Job execution |
Recapture Cond Codes |
Determines whether to save the condition codes from the original Job execution |
Step Adjustment |
Determines whether to enable automatic Step Adjustment. For more details about Step Adjustment, see the Control-M/Restart User Guide. |
Restart Parm Member Name |
Defines the name of the member that contains control parameters for the Job to restart (1-8 characters only). The default value is the member that contains the JCL of the Job. |