The CTMWLI utility accepts parameters using PARM of the EXEC statement.
The first parameter determines the function to perform, with the following available values:
Table 159a Function values in CTMWLI parameter
Function |
Description |
---|---|
INIT |
Initialize a new WLI file and fill it with current definitions of Load-Indexes. |
COPY |
Copy the existing WLI file into another file that you prepared. This new file can be of a different size (typically, a larger file). |
For the INIT function, you can include an additional parameter, as follows:
Table 159b Sizing parameter for INIT function
Parameter |
Description |
---|---|
OPTLIND# |
Maximum number of Load-Indexes to be supported by the WLI data set. An increase in the number of Load-Indexes requires a new WLI data set to be initiated. Valid values: 32–2048 Default: 128 |
For example:
|
The following DD statements are used to point to the files:
Table 159c CTMWLI DD statements
DDNAME |
Description |
---|---|
WLIIN |
Points to the source WLI file (for COPY function only) |
WLIOUT |
Points to the target WLI file |
Parent Topic |