Problem 5 – Incorrect Number of Active Data Sets on a Volume

CTT987E RBA 000208: ACTIVEDS (006) DIFFERS FROM # OF DSN RECORDS FOUND

           (003)

CTT999I V MF0001 SEQ:000

A logical error was detected in a volume record. Volume record field ACTIVEDS specifies the number of active data sets on the volume. This field must contain the same number of data sets as the CTTIDB utility found on the volume.

Use the Inquire/Update screen (TI) to verify the correct number of data sets on the volume and update the ACTIVEDS field in the volume record. In this example, the Inquire/Update screen indicates that volume MF0001 contains three data sets but the FILES field indicated that the volume has six files.

Parent Topic

Sample CTTIDB Output