Activating the Rollback Facility

The Rollback facility is activated by the Rule Activity display (screen BA). Type the letter B in the option field of screen BA and press Enter.

Figure 373 Rule Activity Display Screen

 RULE ACTIVITY   <D> GROUP *                    USERID          JOBNAME

 COMMAND ===>                                                    SCROLL===> CRSR

 O JOBNAME  JOBID STEPNAME          DATE     START ENDED RULE     STATUS  CODE

   M01RUN    8263                   08/08/00 17:04 17:04 RUNALL   OK      0000

   M32ADM    8266                   08/08/00 17:05 17:05 ADMORDER OK      0000

   M15SCH    8276                   08/08/00 17:09 17:09 SCHEDULE OK      0000

   M32ADM    8281                   08/08/00 17:10 17:10 ADMORDER OK      0000

   M32ADM    8284                   08/08/00 17:13 17:13 ADMORDER OK      0000

 B M43LBA    8289                   08/08/00 17:14 17:20 ROLLBACK OK      0000

 ====== >>>>>>>>>>>>>>>>   B O T T O M    O F    L I S T   <<<<<<<<<<<<<< ======

 OPTIONS:   V VIEW L LOG R REPORT B ROLL BACK P PRINT                  17.19.44

A confirmation window appears. To confirm the rollback, type Y and press Enter. To cancel the rollback, type N and press Enter.

If the request is confirmed, variable generations committed by the selected rule invocation are deleted (rolled back). Deleted variable generations continue to be displayed in the Online facility (Screens BA and BV). However, these variable generations cannot be referred to or accessed by Control-M/Analyzer rules.

Figure 374 Rollback Confirmation Screen

 RULE ACTIVITY   <D> GROUP *                    USERID          JOBNAME

 COMMAND ===>                                                    SCROLL===> CRSR

 O JOBNAME  JOBID STEPNAME          DATE     START ENDED RULE     STATUS  CODE

   M01RUN    8263                   08/08/00 17:04 17:04 RUNALL   OK      0000

   M32ADM    8266                   08/08/00 17:05 17:05 ADMORDER OK      0000

   M15SCH    8276                   08/08/00 17:09 17:09 SCHEDULE OK      0000

   M32ADM             +------------------------+ 0 17:10 ADMORDER OK      0000

   M32ADM             |                        | 3 17:13 ADMORDER OK      0000

 B M43LBA    <--------|   CONFIRM      (Y/N)   | 4 17:20 ROLLBACK OK      0000

 ====== >>>>>         |                        | L I S T   <<<<<<<<<<<<<< ======

                      +------------------------+

OPTIONS:   V VIEW L LOG R REPORT B ROLL BACK P PRINT                  17.19.44

After the rollback is completed, a message is displayed at the top of the screen.

After the rollback is completed, a message is displayed at the top of the screen.

Parent Topic

Rollback Facility