Previous Topic

Next Topic

Book Contents

Book Index

Display Type B (Debug)

Figure 39 is an example of the Debug display type (indicated by <B> in the top line of the screen) for the Automation Log screen.

Figure 39 Automation Log Screen Debug Display Type (B)

FuLTER:                      -> AUTOMATION LOG SMF=OS35 <--------< B >-----(OL)

COMMAND ===>                                                    SCROLL===> CRSR

SHOW/SEARCH ON =>                                          DATE 110401 - 110401

DATE   TIME   JOBNAME   ------------------ M E S S A G E ----------------------

110401 090655 E4WGATE   CTWG91W OPEN ACB FAILED. APPLID=ECSLU01A ACBERFLG=58  

    JOBSTEP  GATEWAY    PROCSTEP E4WGATE  JOBID   14333    ASID    00071 JTYPE S

    ID       CTWG91W    TYPE     M        MULTILN R                           

    SYSTEM   OS35       SMFID    OS35     CONSOLE INTERNAL CONID   000         

    HANDLED  Y          SUPPRESS N        CTO     N        RULESEC NONE IOADMIN

    REC.TYPE S          J3FLG    F        SPEC             ENVIR.  000         

    REPLY    0000       HCID              DESC    0000     MCSF    C000        

    ROUTE    80 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00                  

    WRAP IOA 0265       W.EXT 0265        RBA  00221E      EV.COUNT 144328     

                                                                              

110401 090655 E4WGATE   CTWG74I PROBABLE CAUSE: ACB HAS ALREADY BEEN OPENED   

    JOBSTEP  GATEWAY    PROCSTEP E4WGATE  JOBID   14333    ASID    00071 JTYPE S

    ID       CTWG74I    TYPE     M        MULTILN R                           

    SYSTEM   OS35       SMFID    OS35     CONSOLE INTERNAL CONID   000         

    HANDLED  Y          SUPPRESS N        CTO     N        RULESEC NONE IOADMIN

    REC.TYPE S          J3FLG    F        SPEC             ENVIR.  000         

    REPLY    0000       HCID              DESC    0000     MCSF    C000        

    ROUTE    80 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00                  

    WRAP IOA 0265       W.EXT 0265        RBA  00221F      EV.COUNT 144329     

COMMANDS: ALL  LIMIT  LOCATE  SHOW  SHPF  SWAP  TRACE  WRAP  AUTO  '/' 09.08.28

The Debug display type is intended for use in solving problems that cannot be solved without contacting Customer Support. In this case, a list of the Automation Log using this display type should be sent to your BMC Customer Support.

Parent Topic

Automation Log Screen