In reformatting mode, the CTJXVER edit macro uses the following syntax:
CTJXVER REF [P]
A window opens (see the following figure) allowing you to set the parameters, before the processing.
Fig.JV.7.2 Control-M JCL Verify Reformat and Enforcement Facility
------ CONTROL-M JCL REFORMAT AND ENFORCEMENT FACILITY -----
ENTER THE PARAMETERS BELOW: SAVE CHANGES => N (Y/N)
LIBRARY NAME => QUEST.JVER.JCL.RENF
MEMBER NAME => DREF0001
PROCDD =>
NODE NAME => LOCAL SYSTEM NAME => IOA ENV NAME =>
CONSIDER CONTROL-M VARIABLES ==> D (Y/N/D)
ENVIRONMENT => GENERAL
PRESS ENTER TO CONTINUE, END OR PF03/PF15 TO EXIT
This assumes the CLIST command is the default CTJXVER. The value of the ENV parameter, as set in the CONTROL-M JCL REFORMAT AND ENFORCEMENT FACILITY panel, is used in the processing. When CTJXVER is invoked without the P option, the reformatting is performed using the latest default parameters.
For a description of the parameters in this window, see the list of parameters on the Control-M JCL Verify Defaults panel in Verification mode.
Parent Topic |