FILTER: DEFA   +-------------------- IOA LOG SHOW SCREEN -------------------(5)

COMMAND ===>   |  FILTER            SAVE   (Y/N)                              |

SHOW LIMIT O   |  CM     : D JOB M JOB   SHOUT USER GENERAL D INT M INT STAT  |

DATE   TIME    |             Y    Y        Y     Y     Y      N     N    N    |

060800 21354   |  CO+CMEM: GENERAL  SHOUT JOBS      GENERAL W PIPE W JOB W    |

               |             Y        Y    Y                                  |

060601 22040   |  CD+CV  : SBSYS REP MIS SHOUT USER GENERAL DAILY MONIT STAT  |

060601 22040   |             Y    Y   Y    Y     Y     Y      N     N    N    |

060601 22040   |  CB     : RUNTIME SHOUT DAILY GENERAL STATISTICS             |

               |             Y       Y     Y      Y        Y                  |

060601 22040   |  CT     : GENERAL SHOUT      REAL-TIME UTILITIES             |

060601 22040   |             Y       Y            Y        Y                  |

060601 22040   |  CODE                                                        |

               |  URGENCY:      REGULAR Y   URGENT Y   VERY-URGENT Y          |

060601 23034   |  TASK TYPE     CM: JOB CYC EMR STC CST EST ECJ ECS WRN TBL   |

060601 23040   |                     Y   Y   Y   Y   Y   Y   Y   Y   Y   Y    |

060601 23040   |                CD: REP PRT BKP/MIG RST EMR NOEMR CYC NOCYC   |

060601 23040   |                     Y   Y     Y     Y   Y    Y    Y    Y     |

               |  USERID        N54A                                          |

060601 23040   |  MEM/MIS       MIGDASD                                       |

060601 23040   |  JOBNAME                                                     |

060601 23040   |  CATEGORY                                                    |

               |  TABLE                                                       |

               |  ORDERID                                                     |

CMDS: SHOW,    +--------------------------------------------------------------+

The Control-M selection criteria are described in Table 121 in IOA Log Show Screen Window. For descriptions of the selection options for other INCONTROL products, see the user guides of the respective products.

Note: The INCONTROL administrator can limit which installed INCONTROL products and options each user can access. However, because all INCONTROL products and the messages they issue are integrated, it may be important for users to see the messages of products and options to which they have no access. Therefore, the types of messages for all INCONTROL products are listed in the IOA Log Show Screen window, and by default, the messages of all installed products are listed in the IOA Log screen.

Parent Topic

IOA Log Screen