Database List Screen

The Database List screen (also called the IOA Variables In Use screen) displays a list of the variable databases currently defined. This screen can be entered directly from the entry panel or when returning from the Variable List screen.

Note: For a Control-O variable database to be loaded into memory, the database must be listed in the DAGLBLST DD statement of the CMEM monitor. For more information, see the description of the IOA Variable Database facility in the INCONTROL for z/OS Administrator Guide.

Figure 80 IOA Variable Database Facility Database List Screen

LIST OF DATABASES -----  IOA VARIABLES IN USE  ---------------------------(IV)

COMMAND ===>                                                   SCROLL===> CRSR

OPT NAME                  DESCRIPTION                              

    COSALLMT              COSMOS - DEMO - METHODS DATABASE         

    COSALLPR              COSMOS - DEMO - PREREQUISITES DATABASE   

    COSIMGOB              COSMOS - DEMO - SYSIMAGE WORKING DATABASE

    IOAVAR                IOA GLOBAL VARIABLE DATABASE             

    PRDALLMT              COSMOS - PROD - METHODS DATABASE         

    PRDALLPR              COSMOS - PROD - PREREQUISITES DATABASE   

    PRDSTCOB              COSMOS - PROD - STC WORKING DATABASE     

    PRDSTCSD              COSMOS - PROD - STC SOURCE DATABASE      

    PRDVTMOB              COSMOS - PROD - VTAM WORKING DATABASE    

    PRDVTMSD              COSMOS - PROD - VTAM SOURCE DATABASE     

    TUTORIAL              AUTOEDIT DATABASES - TUTORIAL            

    XAES1D01              XESXAE - DEMO - S1 - TEMP                

    XAES1D02              XESXAE - DEMO - S1 - INPUT               

    XAES1D03              XESXAE - DEMO - S1 - PROT (S1PROT SAME AS INPUT)

    XAES1D04              XESXAE - DEMO - S1 - INOUT (S1INOUT SAME AS INPUT)

    XAES2D01              XESXAE - DEMO - S2 - TEMP                

    XAES2D02              XESXAE - DEMO - S2 - INPUT               

    XAES2D03              XESXAE - DEMO - S2 - PROT (S2PROT SAME AS INPUT)

    XAES2D04              XESXAE - DEMO - S2 - INOUT               

===== >>>>>>>>>>>>>>>>>>>>>>>  NO MORE DATABASES  <<<<<<<<<<<<<<<<<<<<<< =====

OPTIONS:  V VIEW VARS                                                08.15.55u

A short description is displayed for each database. You should create a description when creating a new database.