MINIMUM: Basic Scheduling Parameter

Minimum number of free tracks required by the library specified in the PDS parameter.

A related parameter is discussed in PDS: Basic Scheduling Parameter.

Figure 249 MINIMUM Parameter Format

Optional. However, if PDS is specified, MINIMUM is mandatory. The MINIMUM parameter specifies the minimum number of free tracks required. This must be a positive 3-digit number; leading zeros are inserted if necessary.

The MINIMUM parameter cannot be used with the DAYS, WDAYS, MONTHS, CONFCAL, RETRO and DATES parameters.

Parent Topic