Previous Topic

Next Topic

Book Contents

Book Index

General Information for INTERVAL SEQUENCE

The INTERVAL SEQUENCE parameter defines an interval sequence between reruns or cyclic runs of the same job.

Once the job has run, the Control-M Monitor does not rerun or resubmit the job unless both the following conditions are satisfied:

The FROM subparameter specifies the point from which the interval is measured. The values set for this subparameter have the following effects:

A Rerun command (R) can be performed only after all planned intervals have been completed.

The figure below shows an example of the INTERVAL SEQUENCE parameter.

Figure 238 INTERVAL SEQUENCE Parameter Example

JOB: ADBBKPS  LIB  CTM.PROD.SCHEDULE                            TABLE: ADABAS

COMMAND ===>                                                    SCROLL===> CRSR

+---------------------------------------------------------------------------+

  ===========================================================================

  OUT                                                                       

  AUTO-ARCHIVE Y           SYSDB    Y      MAXDAYS      MAXRUNS             

  RETENTION:  # OF DAYS TO KEEP 030  # OF GENERATIONS TO KEEP               

  SYSOUT OP   (C,D,F,N,R)                                               FROM

  MAXRERUN 9    RERUNMEM                                                    

  CYCLIC TYPE: V                                    INTERVAL          FROM  

  INTERVAL SEQUENCE:  + 00030 M + 00004 H + 00007 D +            +          

                      +         +         +         +            +          

  SPECIFIC TIMES:                                               TOLERANCE   

                         +           +          +          +           +    

                                                                            

                                                                            

Parent Topic

INTERVAL SEQUENCE: Runtime Scheduling Parameter