Update parameters generally correspond to the parameters of the Control-M Job Scheduling Definition screen. Not all fields in the Job Scheduling Definition screen can be updated using the utility. Fields that can be updated are listed and described below. For a detailed description of each parameter, see the Job Production parameters chapter in the Control-M for z/OS User Guide.

Note: To update fields that are not supported by the CTMTBUPD utility, such as ONPGM or SHOUT, BMC recommends using a combination of the CTMBLT and CTMTLB utilities described in CTMBLT – Create Tables and CTMTLB – Produce XML and CTMBLT Utility Files, respectively. Once the CTMTLB utility has produced statements in the format suitable as input to the CTMBLT utility, these can be edited or updated with any editor, such as ISPF edit, and then run through the CTMBLT utility to recreate the tables with the desired changes.

Fields to be updated can fall into either of two categories:

Fields Easily Updated

You can update the fields shown in Table 151a by specifying the new desired values in the following format:

parm_name=new_value

where

Note: In Table 151a, an asterisk in column * indicates that character masking can be specified for the parameter as follows:

If an asterisk is specified following a character string, the character string is treated as a prefix (meaning, only the first n characters of the parameter, corresponding to the number of characters preceding the *, participate in the modification).

If the character string begins with one or more asterisks, the number of characters at the start of the parameter value corresponding to the number of asterisks specified do not participate in the modification.

Table 151a CTMTBUPD Parameters

Parameter

*

Value

Description

ACTIVE-FROM

 

6 digits in format yymmdd

Schedule RBC Definition Active From date

ACTIVE-UNTL

 

6 digits in format yymmdd

Schedule RBC Definition Active Until date

ADJUST-CONDITION

 

Y (Yes), N (No), D (Dummy),
or B (Bridge)

Adjust conditions indicator. For SMART Table Entities only

APPL

*

1 through 20 characters

Application name

AUTOARC

 

Y (Yes) or N (No)

Archive SYSDATA

CATEGORY

 

1 through 20 characters

Category for Control-D

CONFCAL

 

1 through 8 characters

Confirmation calendar name

CONFIRM

 

Y (Yes) or N (No)

Confirmation for schedule

CYCLIC-TYPE

 

C, S, V

Type of interval between cycles: C – constant; S – specified; V – varying

CYC-RUNTIME

 

hhmm,nnn

Enhanced cyclic specific run times in 24-hour format: hh (hour), mm (minutes) with an optional day-offset (nnn)

DATES

 

4 digit dates, separated by commas

DATES scheduling

DAYS

 

For information, see the Job Production parameters chapter of the Control-M for z/OS User Guide

Scheduling days

DAYSFROM

 

3 digits (0–120)

Time FROM days offset

DAYSKEEPNOK

 

2 digits (0–99)

The minimal number of days that the folder and its jobs are kept in the AJF after the folder is marked as "NOT-OK".

1-98 – Number of days to keep.

99 – Keep forever.

The above two options are invalid when REMOVEATONCE is set to "No".

0 – Do not keep (Default). This is the only valid value when REMOVEATONCE is set to "No".

DAYSUNTIL

 

3 digits (0–120)

Time UNTIL days offset

DAYS-DUEOUT

 

3 digits (0–120)

Due-out time days offset

DCAL

 

1 through 8 characters or "*"

DAYS calendar name

DEL-RBC

*

1 through 20 characters

Name of RBC to delete from the SMART Table

DESC

 

1 through 50 characters

Description of job

DOCLIB

*

1 through 44 characters

Documentation library name

DOCMEM

*

1 through 8 characters

Documentation member name

DUE-OUT

 

[+/-]hhmm

Due out time

INSERT-RBC

*

1 through 20 characters

Name of RBC to insert into the SMART Table

INTERVAL

 

5 digits (0-64800)

Minutes between reruns

INTERVAL-TYP

 

1 character: S (Start), E (End),

or T (Target)

Interval type

INTERVL-UNIT

 

M, H, D

The units in which INTERVAL is expressed (Minutes, Hours, or Days)

MAXDAYS

 

2 digits

Expiration period

MAXRERUN

 

4 digits

Maximum number of reruns

MAXRERUN - CYC

 

4 digits; 0 through 9999

Maximum number of cyclic runs. Effective only if TASKTYPE is set to CYC for job or TBC for cyclic SMART Table.

MAXRUNS

 

3 digits

Maximum number of runs

MAXWAIT

 

2 digits

Maximum days job is retained

0-98 (default is 0)

99 indicates "forever"

MEMLIB

*

1 through 44 characters

Library containing JCL member

MEMNAME

*

1 through 8 characters

JCL member name

NJE-NODE

 

1 through 8 characters

NJE node identifier

OVERLIB

*

1 through 44 characters

Overriding JCL library name

OWNER

*

1 through 8 characters

User-identification

PREVENT-NCT2

 

Y (Yes) or N (No) or F or L

Prevent ‘NOT CATLGD 2’ errors

PRIORITY

 

1 to 2 characters

Priority

RBC

*

1 through 20 characters

Schedule RBC name

RBC-LEVEL

 

CTM or TBL

Indicates whether this is a Control-M Rule-based Calendar or a Table Rule-based Calendar

RBC-RELATION

 

1 character (blank, O, A)

RBC And/Or relationship

RELATION

 

A or O

AND or OR relation

REMOVEATONCE

 

Y (Yes) or N (No - default)

Indicates that all the jobs will be removed together, when the folder is ready to be removed.

RETDAYS

 

3 digits

Maximum number of days to retain

RETGENS

 

2 digits

Maximum number of generations to retain

RETRO

 

Y (Yes) or N (No) - Y (Yes) is not valid in SMART Tables

Retroactive selection

SCHENV

 

1 through 16 characters

Workload management scheduling environment

SHIFT

 

1 character: >, <, @, blank

Shift on confirmation calendar

SHIFT-EXT

 

3 characters: ±nn, or blank

For a description, see the Control-M for z/OS User Guide

SAC

 

1 character (P, N, -, +, blank)

Schedule adjustment for conversion

SYSDB

 

Y (Yes) or N (No)

Archive to common data set

SYSTEM-ID

 

1 through 4 characters

SYSTEM-ID identifier

TABLE

*

1 through 20 characters

Table name

TASKTYPE

 

3 characters

Type of task (job, started task, and so on. For SMART Tables the valid values are: TBC - cyclic SMART Table and TBL - regular table)

TIMEFROM

 

[+/-]hhmm

Earliest time to submit job

TIMEUNTIL

 

[+/-]hhmm,>

Latest time to submit job, submit as soon as possible

TIME-ZONE

 

3 characters

Time zone designation

TOLERANCE

 

1 to 4 digits

Enhanced cyclic tolerance - the maximum number of minutes after the specified time permitted for a late submission.

VAR-INTERVAL

 

nnnnn,unit

Enhanced cyclic varying interval (nnnnn - interval length, unit = M (Minutes), H (Hours), D (Days)

WCAL

 

1 through 8 characters or "*"

WDAYS calendar name

WDAYS

 

For information, see the Control-M for z/OS User Guide

Weekly scheduling days

Note:

Parent Topic