Step 3.1 – Control-O target libraries and members

Enter values for the parameters shown in the following table.

Note: When specifying values for parameters or subparameters that include both unit and volser fields, you must either define both the Unit and Volser fields, or leave both of them blank. Do not enter a value for only one of them.

Table 97 Target library and member parameters

Parameter

Description

ILPREFO

High level data set name qualifiers (prefix) of the Control‑O Installation libraries.

  • Mandatory
  • Maximum length: 35 characters

The value specified for this parameter must be different from the values specified for ILPREFx parameters of other products.

ILUNITO

Disk unit on which Control‑O Installation libraries are placed. Specify a generic unit (for example, 3390 – not SYSDA).

ILVOLO

Volume serial number on which Control‑O Installation libraries are placed.

OLPREFO

High level data set name qualifiers (prefix) of the Control‑O Operations libraries and files.

  • Mandatory
  • Maximum length: 27 characters.

Note: Control‑O Operational libraries may have to be defined in the master catalog. For details, see Control-O installation sheet.

OLUNITO

Disk unit on which Control‑O Operations libraries and files are placed. Specify a generic unit (for example, 3390 – not SYSDA).

  • Mandatory

OLVOLO

Volume serial number on which Control‑O Operations libraries and files are placed.

  • Mandatory

Parent Topic