Step 3.2 – MVS procedures and CTJ CLIST name

Table 144 MVS Procedure and CTJ CLIST name parameters

Parameter

Description

PROCPRFJ

First three characters of the Control‑M/JCL Verify JCL procedures after they are copied to the local MVS procedure library.

  • Mandatory
  • Default: CTJ

The value specified for this parameter must be different than the value specified for the PROCPRFx installation parameter for other INCONTROL products.

CLISTNMJ

New name for REXX "CTJXVER" copied from IOA CLIST library to SYSPROC Site library. Mandatory. Default: CTJXVER.

You can use for the CLIST any valid name, like JV or JVER, to simplify the usage of Control-M/JCL Verify.

If you are specifying a name for the CLISTNMJ parameter, which is not the default, the SYSPROCA parameter must not be set to DONTCOPY in Install IOA Step 5.3 (MVS procedures), but instead a data set name for the SYSPROC site library must be defined in Step 5.3, then verified in Step 6.1 (Parameter verification), and finally saved in Step 6.2 (Save parameters into IOA libraries).

Parent Topic