This group includes messages for the Control-D, Control-D/Image, and Control-D/Page on Demand products.
Explanation: This information message indicates the normal start of the CTDAMUTI utility.
Corrective Action: No action is required.
Explanation: This information message indicates the normal termination of the CTDAMUTI utility.
Corrective Action: No action is required.
Explanation: The CTDAMUTI Compressed Dataset Access Method utility ended with errors.
This is a general message when the CTDAMUTI utility ends with errors. The job sysout should contain prior messages detailing the reasons.
Corrective Action: No action is required.
Explanation: An invalid function was given to the CTDAMUTI Control-D utility.
For more information, refer to the section on the CTDAMUTI CDAM Maintenance Utility in the Control-D and Control-V User Guide.
The CTDAMUTI utility terminates with a return code of 08.
Corrective Action: Correct the function, and rerun the CTDAMUTI utility.
Explanation: No CDAM data sets were found that match the data set identification parameters given to the CTDAMUTI utility.
The CTDAMUTI CDAM Maintenance Utility attempts to locate CDAM data sets based on the data set identification parameters given to it. For more information, see the Control-D and Control-V User Guide.
One of the following problems is present:
The CTDAMUTI utility will terminate with a return code of 04.
Corrective Action:
Explanation: The open of the SYSIN DD statement failed.
For more information, see the section on the CTDAMUTI CDAM Maintenance Utility in the Control-D and Control-V User Guide.
Possible causes are:
The CTDAMUTI utility terminates with a return code of 12.
Corrective Action: Correct the CTDAMUTI JCL and rerun the utility.
Explanation: This information message from the CTDAMUTI utility indicates that CDAM data set dsn was copied successfully.
The CTDAMUTI utility terminates with a return code of 0.
Corrective Action: No action is required.
Explanation: This information message from the CTDAMUTI utility indicates that CDAM data set dsn was deleted successfully.
The CTDAMUTI utility terminates with a return code of 0.
Corrective Action: No action is required.
Explanation: The dsn CDAM data set is not a sysout file, meaning, a SYSOUT parameter was not specified when this CDAM file was created.
This warning message is issued by the CTDAMUTI utility.
The sysout class is set to *, and the dsn CDAM data set is printed.
Corrective Action: No action is required.
Explanation: Internal error in the CTDAMUTI utility.
The dynamic allocation of a sysout print file by the CTDAMUTI utility failed.
The CTDAMUTI utility terminates with a return code of 12.
Corrective Action: Have your system programmer call your IOA representative for assistance.
Explanation: No CDAM selection parameters were specified in the input of the CTDAMUTI utility.
At least one CDAM selection parameter must be specified in the input of the CTDAMUTI utility.
The CTDAMUTI utility ends with an error.
Corrective Action: Rerun the CTDAMUTI utility specifying CDAM selection parameters.