Previous Topic

Next Topic

Book Contents

Book Index

Messages STO100 through STO1xx

This group includes messages for the Control-O product.

STO171S STATISTICS FILE OVERFLOW

Explanation: All Statistics file index entries are in use. No new statistics can be accumulated.

The Statistics Facility could not accumulate statistics because the number of message IDs exceeds the maximum number of allowable entries in the Statistics file.

Statistics accumulation stops.

Corrective Action: Please review the following recommendations; then format the Statistics file and restart the Statistics Facility:

  1. Enlarge the Statistics file by using the following procedure: a. Increase the value of the STREC# parameter in CTOPARM.b. Delete or rename the old Statistics file to allow a new Statistics file allocation.c. Allocate and format a new Statistics file.
  2. Use AutoEdit option %%$STATID to customize message ID determination. This option can be used to decrease the number of message IDs that are generated. See the INCONTROL for z/OS Administrator Guide for more information.

STO172S STATISTICS FILE IS NOT FREE

Explanation: The Statistics file is locked.

Either the Statistics file is in use by another Control-O monitor or utility, or Control-O abended previously while updating the Statistics file.

Statistics accumulation is not performed.

Corrective Action: Check if another Control-O monitor or utility uses this Statistics file. If this is not the case, then reformat the Statistics file and restart the Statistics Facility.

STO173S OPEN OF STATISTICS FILE FAILED

Explanation: The Control-O Statistics facility attempted to open the Statistics file but did not succeed.

Failure to open the Statistics file may be due to the following:

Statistics accumulation is not performed.

Corrective Action: Look for previous MVS error messages regarding the opening of the Statistics file. Correct the error and rerun the job.

STO174S FILE ALLOCATED TO DDNAME "DASTF" IS NOT A CONTROL-O STATISTICS FILE

Explanation: The Control-O Statistics Facility attempted to read the file allocated to DD name DASTF, but it is not a formatted Statistics file.

Statistics accumulation is not performed.

Corrective Action: Format the Statistics file and restart the Statistics Facility.

STO175E RELEASE OF THE STATISTICS FILE IS NOT SUPPORTED BY THIS RELEASE

Explanation: The format of the Statistics file is not supported by the current release of Control-O. The Statistics file could not be read by the Control-O Statistics Facility.

The Statistics file was formatted by an earlier release of Control-O.

Statistics accumulation is not performed.

Corrective Action: Format the Statistics file in the currently supported format, and restart the Statistics Facility.

STO176E THE STATISTICS FILE BELONGS TO A DIFFERENT CONTROL-O MONITOR

Explanation: The assigned ID of the Statistics file does not match the ID of the Control-O monitor.

When a Statistics file is formatted, it is associated with a particular Control-O monitor. The CTOMFST Statistics Formatting utility takes the ID of the Control-O monitor from the QNAME parameter in CTOPARM, and assigns it to the Statistics file.

The ID of the active Control-O monitor does not match the assigned ID of the Statistics file. The probable cause of the error is that the value of QNAME was changed without reformatting the Statistics file.

Statistics accumulation is not performed.

Corrective Action: Format the Statistics file with the correct Control-O ID and restart the Statistics Facility.

STO177S CONTROL-O STATISTICS SEVERE INTERNAL ERROR, ID=code

Explanation: The Control-O Statistics Facility encountered an internal error.

In this message, code is the internal error code.

Statistics accumulation stops.

Corrective Action: Look for previous messages to identify the cause of the problem and contact BMC Customer Support.

STO178S STORAGE ALLOCATION FOR STATISTICS FAILED

Explanation: Storage allocation for the Control-O Statistics Facility failed because the Statistics Facility could not obtain enough working storage for processing.

Statistics accumulation is not performed.

Corrective Action: Increase the Control-O region size and restart a new Control-O monitor.

STO179S I/O ERROR ACCESSING THE STATISTICS FILE

Explanation: A READ/WRITE error occurred when accessing the Statistics file.

Statistics accumulation stops.

Corrective Action: Look for previous MVS error messages regarding Statistics file I/O errors, and correct accordingly. If MVS messages do not clarify the error, please contact BMC Customer Support.

STO180S CONTROL-O STATISTICS FILE INTERNAL ERROR. RECORD TYPE MISMATCH

Explanation: The Statistics Facility has encountered a corruption in the Statistics file. The Statistics file cannot be processed.

Statistics accumulation stops.

Corrective Action: Contact BMC Customer Support.

STO181S CONTROL-O STATISTICS INTERNAL ERROR. WRITE FAILED FOR SECTION section

Explanation: Due to an internal error, update of the Statistics file failed while writing a section of the Statistics file.

Statistics accumulation stops.

Corrective Action: Contact BMC Customer Support.

STO182S CLOSE OF CONTROL-O STATISTICS FILE FAILED

Explanation: During termination, the Control-O Statistics Facility failed to close the Statistics file.

The Statistics Facility continues terminating without closing the Statistics file.

Corrective Action: Check the system log for previous error messages. If none are found, please contact BMC Customer Support.

STO184I CONTROL-O STATISTICS ACCUMULATION STARTED

Explanation: This informative message indicates that the Control-O Statistics Facility initialization completed successfully and that Control-O statistics are being accumulated.

Corrective Action: No action is required.

STO185S CONTROL-O STATISTICS INITIALIZATION ERROR

Explanation: Control-O Statistics Facility did not initialize successfully.

Statistics accumulation is not performed.

Corrective Action: Look for previous error messages in the IOA Log to determine the cause of the error, and then correct accordingly.

STO186E STATISTICS ACCUMULATION ERROR WHILE PROCESSING SUBSYSTEM REQUESTS

Explanation: The Statistics Facility detected an error while processing requests from the Control-O subsystem.

Statistics accumulation stops.

Corrective Action: Look for previous error messages in the IOA Log to determine the cause of the error, and then correct accordingly.

STO187E STATISTICS ACCUMULATION ERROR DURING FILE UPDATE

Explanation: The Statistics Facility detected an error while updating the Statistics file.

Statistics accumulation stops.

Corrective Action: Look for previous error messages in the IOA Log to determine the cause of the error, and then correct accordingly.

STO189I CONTROL-O STATISTICS ACCUMULATION ENDED

Explanation: This informative messages is issued after normal termination of the Statistics Facility. Statistics accumulation is discontinued.

Corrective Action: No action is required.

STO190S CONTROL-O STATISTICS TERMINATION ERROR

Explanation: Control-O Statistics Facility did not terminate successfully.

The Statistics Facility continues the termination process.

Corrective Action: Look for previous error messages in the IOA Log to determine the cause of the error, and then correct accordingly.

STO191S STATISTICS ACCUMULATION ERROR WHILE PROCESSING USER REQUESTS

Explanation: The Statistics Facility detected an error while processing a SHOW, EXCLUDE or RESET online user request.

Statistics accumulation stops.

Corrective Action: Look for previous error messages in the IOA Log to determine the cause of the error, and correct accordingly.

STO192E STATISTICS REQUEST FOR MESSAGE ID msgId FAILED - MESSAGE ID NOT FOUND

Explanation: A SHOW, EXCLUDE or RESET request for message ID msgId failed.

An online user requested a SHOW/EXCLUDE/RESET for message ID msgId. This message ID was not found in the Statistics file.

The online request is not performed. The Statistics Facility continues processing.

Corrective Action: Notify BMC Customer Support of the problem.

STO193E STATISTICS REQUEST FOR MESSAGE ID msgId FAILED - INVALID REQUEST

Explanation: Due to an internal error, the user’s online request regarding message ID msgId was not recognized.

The request is not performed. The Statistics Facility continues processing.

Corrective Action: Notify BMC Customer Support.

STO194W WAITING FOR THE STATISTICS FILE - FILE IN USE

Explanation: Control-O is attempting to access the Statistics file, but it is in use by another Control-O monitor or Control-O utility.

Control-O waits and attempts to access the Statistics file again.

Corrective Action: This message is not necessarily the result of an error. It may be issued while generating a statistics report or when the Online Facility attempts to access the Statistics file. If the Statistics file is not freed in a reasonable period of time, check what job is using it and free it.

STO195E RESET OF STATISTICS FOR MESSAGE ID msgId FAILED

Explanation: An online user requested a RESET of the statistics for message ID msgId, but due to internal error, the request could not be performed by Control-O.

The RESET request is not performed. The Statistics Facility continues processing.

Corrective Action: Notify BMC Customer Support.

STO196S STATISTICS FILE DYNAMIC ALLOCATION ERROR rc/rsn/dsn

Explanation: Dynamic allocation of Statistics file dsn failed with return code rc and reason code rsn.

Statistics accumulation is not performed.

Corrective Action: See the IBM manual MVS Programming: Authorized Assembler Services Guide to determine this cause of the error, and correct the error accordingly. If not successful, contact BMC Customer Support.

STO197I CONTROL-O STATISTICS GLOBAL RESET COMPLETE

Explanation: This information message indicates that a global statistics reset was completed successfully.

Global statistics reset command F CONTROLO, RESETSTAT was issued and performed successfully.

Corrective Action: No action is required.

STO198E RESET OF DATE FOR MESSAGE ID msgId FAILED

Explanation: Statistics for message ID msgId were reset as requested, but due to an internal error, update of the last reset date was not successful.

Statistics are reset. The Statistics Facility continues processing, but the indicated last reset date is incorrect.

Corrective Action: Notify BMC Customer Support.

STO199I STATISTICS OF MESSAGE ID msgId RESET

Explanation: This informative message indicates that the requested statistics reset for message ID msgId was successfully performed.

Corrective Action: No action is required.

Parent Topic

STO messages