SSO230E SUBSYSTEM cto_subsys_name INITIALIZATION FAILED - JES COMMAND SUPPRESSION NOT ACTIVATED

Explanation: During Control-O initialization, Control-O failed to activate the Control-O subsystem (cto_subsys_name) that is used to suppress JES2 commands.

To suppress JES2 commands, Control-O uses the subsystem identified in the JCMDSSN parameter in the CTOPARM member in the IOA PARM library. That subsystem must be defined in SYS1.PARMLIB(IEFSSN xx), and must be activated in the last IPL before Control-O is started.

Control-O initialization continues, but the JES2 command suppression function is disabled.

Corrective Action: Notify the INCONTROL administrator.

SSO231E SUBSYSTEM cto_subsys_name WAS NOT PRE-DEFINED - JES COMMAND SUPPRESSION NOT ACTIVATED

Explanation: During Control-O initialization, Control-O failed to activate the Control-O subsystem (cto_subsys_name) that is used to suppress JES2 commands, because the subsystem was not properly predefined.

To suppress JES2 commands, Control-O uses the subsystem identified in the JCMDSSN parameter in the CTOPARM member in the IOA PARM library. That subsystem must be defined in SYS1.PARMLIB(IEFSSN xx), and must be activated in the last IPL before Control-O is started.

Control-O initialization continues, but the JES2 command suppression function is disabled.

Corrective Action: Notify the INCONTROL administrator.

SSO234W SUBSYSTEM subsys ALREADY INACTIVE

Explanation: During Control-O termination, Control-O deactivates the IOA subsystem and the Control-O subsystem currently in use. On this occasion, the subsystem identified in the message was already inactive.

Control-O termination continues.

Corrective Action: Notify the INCONTROL administrator.

SSO235W subsys ALREADY ACTIVE

Explanation: During Control-O initialization, Control-O tried to activate the IOA subsystem and the Control-O subsystem, but detected that the subsys subsystem was already active.

Control-O initialization continues.

Corrective Action: Notify the INCONTROL administrator.

SSO236E ERROR WHILE ATTEMPTING TO OPEN THE STEPLIB DATASET

Explanation: Control-O could not open file STEPLIB.

Control-O encountered an error opening the STEPLIB file while attempting to activate the alternate subsystem.

Control-O continues without activating the alternate subsystem.

Corrective Action: Verify that a STEPLIB library or concatenation of libraries exists. Reactivate Control-O.

SSO237E ERROR WHILE ATTEMPTING TO LOCATE (BLDL) ONE OF THE SUBSYSTEM FUNCTION ROUTINES

Explanation: Control-O could not find at least one of the alternate subsystem function routines.

While attempting to activate the alternate subsystem, Control-O could not find at least one of the alternate subsystem function routines in the STEPLIB library or concatenation of libraries.

Control-O continues without activating the alternate subsystem.

Corrective Action: Verify that these modules exist in the STEPLIB library or concatenation of libraries and reactivate Control-O.

SSO238E ERROR WHILE ATTEMPTING TO LOAD ONE OF THE SUBSYSTEM FUNCTION ROUTINES

Explanation: Control-O could not load at least one of the alternate subsystem function routines.

While attempting to activate the alternate subsystem, Control-O could not find at least one of the alternate subsystem function routines in the STEPLIB library or concatenation of libraries.

Control-O continues without activating the alternate subsystem.

Corrective Action: Verify that these modules exist in the STEPLIB library or concatenation of libraries and reactivate Control-O.

SSO239E ERROR WHILE ATTEMPTING TO ACQUIRE STORAGE FOR SUBSYSTEM FUNCTION ROUTINES OR THE SSVT

Explanation: Control-O could not acquire enough CSA (Common Service Area) storage to load alternate subsystem function routines or to build the SSVT for the alternate subsystem.

Control-O continues without activating the alternate subsystem.

Corrective Action: If storage defined for CSA is not large enough, increase the CSA size and perform an IPL.

SSO23AI ALTERNATE SUBSYSTEM subsys SUCCESSFULLY INITIALIZED

Explanation: This information message indicates that the CTOSSO module successfully activated the alternate subsystem.

Corrective Action: No action is required.