This group includes messages for the Control-D, Control-D/Image, and Control-D/Page on Demand products.
Explanation: While a report was being viewed online during processing of the SPAGE command, an internal error occurred. The SPGB parameter address was found to be 0.
The SPAGE command is not processed.
Corrective Action: Do the following:
Explanation: An internal error occurred while a report was being viewed on line during processing of the SPAGE command. Storage could not be obtained for the initial SPAGE block.
The SPAGE command is not processed.
Corrective Action: Increase the region size and retry the SPAGE command.
Explanation: An internal error occurred while a report was being viewed on line during processing of the SPAGE command. Storage could not be obtained for the program work area.
The SPAGE command is not processed.
Corrective Action: Increase the region size and retry the SPAGE command.
Explanation: An internal error occurred while a report was being viewed on line during processing of the SPAGE command. The RECORD parameter address was found to be 0.
The SPAGE command is not processed.
Corrective Action: Do the following:
Explanation: You are not authorized to use the SPAGE command.
The SPAGE command is not processed.
Corrective Action: Notify your INCONTROL administrator.
Explanation: An internal error occurred while a report was being viewed on line during processing of the SPAGE command. The excess storage of the existing space block could not be released.
The SPAGE command is not processed.
Corrective Action: Do the following:
Explanation: An internal error occurred while a report was being viewed on line during processing of the SPAGE command. The excess storage of the extended size space block could not be released.
The SPAGE command is not processed.
Corrective Action: Increase the region size and retry the command.
Explanation: An internal error occurred while a report was being viewed on line during processing of the SPAGE command. The excess storage of the copied space block could not be released.
The SPAGE command is not processed.
Corrective Action: Do the following:
Explanation: An internal error occurred while a report was being viewed on line during processing of the SPAGE command. The function ID parameter address was found to be 0.
The SPAGE command is not processed.
Corrective Action: Do the following:
Explanation: An internal error occurred while a report was being viewed on line during processing of the SPAGE command. The function ID code was found to be invalid.
The SPAGE command is not processed.
Corrective Action: Do the following:
Explanation: An internal error occurred while a report was being viewed on line during processing of the SPAGE command. The WORD COUNT parameter address was found to be 0.
The SPAGE command is not processed.
Corrective Action: Do the following:
Explanation: An internal error occurred while a report was being viewed on line during processing of the SPAGE command. The CURRENT PAGE parameter address was found to be 0.
The SPAGE command is not processed.
Corrective Action: Do the following:
Explanation: While a report was being viewed on line during processing of the SPAGE command, a parameter was not recognized.
The SPAGE command is not processed.
Corrective Action: Correct the parameter in the command and retry the command.
Explanation: An internal error occurred while a report was being viewed on line during processing of the SPAGE command. The WORD LIST parameter address was found to be 0.
The SPAGE command is not processed.
Corrective Action: Do the following:
Explanation: While a report was being viewed on line during processing of the SPAGE command, the length of a parameter was found to be invalid.
The SPAGE command is not processed.
Corrective Action: Correct the length of the problematic parameter and retry the command.
Explanation: While a report was being viewed on line during processing of the SPAGE command, the number of a page was found to be invalid.
Page numbers in the SPAGE command must be in the range from 1 through 99999999.
The SPAGE command is not processed.
Corrective Action: Correct the problematic page number and retry the command.
Explanation: While a report was being viewed on line during processing of the SPAGE command, the number of the end page was found to have been specified before the number of the start page.
In the SPAGE command, the start page number must appear before the end page number.
The SPAGE command is not processed.
Corrective Action: Correct the problematic page number and retry the command.
Explanation: While a report was being viewed on line during processing of the SPAGE command, the specified start page number was found to be greater than the specified end page number.
In the SPAGE command, the start page number must be less than the end page number.
The SPAGE command is not processed.
Corrective Action: Correct the problematic page number and retry the command.
Explanation: An internal error occurred while a report was being viewed on line during processing of the SPAGE command. The security exit call routine address was found to be 0.
The SPAGE command is not processed.
Corrective Action: Do the following:
Explanation: An internal error occurred while a report was being viewed on line during processing of the SPAGE command. The security exit function ID address was found to be 0.
The SPAGE command is not processed.
Corrective Action: Do the following:
Explanation: An internal error occurred while a report was being viewed on line during processing of the SPAGE command. The specified start page number was found to be greater than the number of pages in the report.
The SPAGE command is not processed.
Corrective Action: Correct the problematic page number and retry the command.
Explanation: An internal error occurred while a report was being viewed on line during processing of the SPAGE command.
The SPAGE command does not support $SYSDATA records.
The SPAGE command is not processed.
Corrective Action: Exit from the $SYSDATA record, reenter a User record, and retry the SPAGE command.
Parent Topic |