This group includes messages for the Control-D, Control-D/Image, and Control-D/Page on Demand products.

SMF041S SMFWTM RETURNED RC= 4 - SMF RECORD TOO LONG

Explanation: Highlighted, unrollable message.

Control-D attempted to write an SMF record which could not fit completely in an SMF data set.

The user modified Control-D Exit CTDX006, but moved an incorrect value to the SMFLEN field (DSECT CTDUSMF). This field contains the length of the SMF record.

The SMF record is not written, but Control-D continues processing. Control-D sets an internal indication that a permanent error is present on SMF recording, and will not continue to attempt SMF recording. From this point on, instead of writing to SMF, message SMF049I is written to the IOA Log. This log message is a replacement for SMF recording, and can be entered into SMF after the problem is fixed.

Corrective Action: Correct the problem in CTDX006, assemble and link-edit this exit, and bring down Control-D. When Control-D is brought up again, SMF recording will resume.

SMF042S SMFWTM RETURNED RC= 8 - SMF RECORD TOO SHORT

Explanation: Highlighted, unrollable message.

Control-D attempted to write an SMF record which is smaller than 18 characters long.

The user modified the Control-D Exit CTDX006, but moved an incorrect value to the SMFLEN field (DSECT CTDUSMF). This field contains the length of the SMF record.

The SMF record is not written, but Control-D continues processing. Control-D sets an internal indication that a permanent error is present on SMF recording, and will not continue to attempt SMF recording. From this point on, instead of writing to SMF, message SMF049I is written to the Control-D log. This log message is a replacement for SMF recording, and can be entered into SMF after the problem is fixed.

Corrective Action: Correct the problem in CTDX006, assemble and link-edit this exit, and bring down Control-D. When Control-D is brought up again, SMF recording will resume.

SMF043S SMFWTM RETURNED RC= 16 - SMF IS NOT ACTIVE

Explanation: Highlighted, unrollable message.

Control-D attempted to write an SMF record, but SMF is not active.

The SMF record is not written, but Control-D continues processing. Control-D sets an internal indication that a permanent error is present on SMF recording, and will not continue to attempt SMF recording. From this point on, instead of writing to SMF, the message SMF049I is written to the IOA Log. This log message is a replacement for SMF recording, and can be entered into SMF after the problem is fixed.

Corrective Action: Initiate SMF recording, then bring down Control-D. When Control-D is brought up again, SMF recording will resume.

SMF044S SMFWTM RETURNED RC= 20 - SMF EXIT IEFU83 SUPPRESSED THE RECORD

Explanation: Highlighted, unrollable message.

Control-D attempted to write an SMF record, but SMF exit IEFU83 suppressed the record.

The SMF record is not written, but Control-D continues processing. Control-D sets an internal indication that a permanent error is present on SMF recording, and will not continue to attempt SMF recording. From this point on, instead of writing to SMF, message SMF049I is written to the IOA Log. This log message is a replacement for SMF recording, and can be entered into SMF after the problem is fixed.

Corrective Action: Correct SMF exit IEFU83 to allow Control-D to write SMF records. When Control-D is brought up again, SMF records will resume.

SMF045S SMFWTM RETURNED RC= 24 - THE SMF FILES ARE FULL

Explanation: Highlighted, unrollable message.

Control-D attempted to write an SMF record, but the SMF files are full.

The SMF record is not written, but Control-D continues processing. Control-D will write message SMF049I to the IOA Log file. This log message is a replacement for SMF recording, and can be entered into SMF later.

Control-D will keep attempting to write to the SMF file. If the SMF file is still full, message SMF049I will be written to the log.

Please note that Control-D does not have to be taken down. As soon as room is found on an SMF file, SMF recording will take place automatically.

Corrective Action: The operator should clear SMF files according to the conventions of the site. As soon as this is done, Control-D will automatically continue with SMF recording.

SMF046S INTERNAL PROBLEM IN MVS. SMF RECORD NOT WRITTEN

Explanation: Highlighted, unrollable message.

Control-D attempted to write an SMF record, but there is an internal problem in MVS.

This is due to one of the following return codes from MVS:

Return Code

Explanation

26

Record is not currently being recorded.

40

Buffer storage caused data to be lost.

44

SVC 83 unable to establish recovery.

Refer to message SMF047S for the return code.

The SMF record is not written, but Control-D continues processing. Control-D sets an internal indication that a permanent error is present on SMF recording, and will not continue to attempt SMF recording. From this point on, instead of writing to SMF, message SMF049I is written to the IOA Log. This log message is a replacement for SMF recording, and can be entered into SMF after the problem is fixed.

Corrective Action: Call the system programmer. After the problem is fixed by the system programmer, bring down Control-D. When Control-D is brought up again, SMF recording will resume.

SMF047S RC=rc RECEIVED FROM MACRO SMFWTM

Explanation: Highlighted, unrollable message.

Control-D is unable to write SMF records. Possible causes are:

The SMF record is not written, but Control-D continues processing. Control-D sets an internal indication that a permanent error is present on SMF recording, and will not continue to attempt SMF recording. From this point on, instead of writing to SMF, message SMF049I is written to the Control-D log. This log message is a replacement for SMF recording, and can be entered into SMF after the problem is fixed.

Corrective Action: Call the INCONTROL administrator.

SMF048S CONTROL-D SMF RECORDING IS TERMINATED - PLEASE TAKE CORRECTIVE ACTION

Explanation: Highlighted, unrollable message.

Control-D is unable to write SMF records.

This message is issued whenever a permanent error is present on SMF recording. This message is issued for messages SMF041S through SMF050S.

The SMF record is not written, but Control-D continues processing.

In the case of a non-permanent SMF error under IOA Online, Control-D Decollation Monitor, or Control-D Application Server address space, the SMF recording is deactivated and the one time warning message SMF048S is issued.

Corrective Action: Refer to messages SMF041S through SMF050S. In the case where the message is issued due to a non-permanent SMF error under IOA Online, Control-D Decollation Monitor, or Control-D Application Server address space, refer to the SMF MODIFY command description in the SMF Accounting chapter of the INCONTROL for z/OS Administrator Guide. Eliminate the cause of the error and issue the SMF MODIFY command to an appropriate address space in order to re-activate SMF writing.

SMF049I USER=user ODATE=date COP=#copies P=#pages L=#lines

Explanation: If STAT is set to Y in CTDPARM, this information message is issued when a Printing Mission prints a report.

date is in either mmdd or ddmm format, depending on the site standard.

Corrective Action: No action is required.

SMF04AI CONTROL-D SMF RECORDING IS ACTIVE

Explanation: The SMF recording is active for this Control-D address space.

The message is issued in one of the following cases:

Corrective Action: No action is required.

SMF04BI CONTROL-D SMF RECORDING IS NOT ACTIVE

Explanation: The SMF recording is not active for this Control-D address space.

The message is issued after the SMF modify command was issued for the Control-D address space, but the corresponding parameter SMFxxx=NO was defined the in IOAPARM/CTDPARM.

Corrective Action: In order to activate SMF recording, the user must define the corresponding SMFxxx parameter and then restart the Control-D address space.

SMF050S INVALID VALUE value IN THE INSTALLATION PARAMETER "SMF"

Explanation: Highlighted, unrollable message.

Control-D attempted to write an SMF record, but an invalid value is present on the SMF field in CTDPARM.

The SMF field in CTDPARM can contain the following values:

The SMF record is not written, but Control-D continues processing. Control-D sets an internal indication that a permanent error is present on SMF recording, and will not continue to attempt SMF recording. From this point on, instead of writing to SMF, message SMF049I is written to the IOA Log. This log message is a replacement for SMF recording, and can be entered into SMF after the problem is fixed.

Corrective Action: Call your INCONTROL administrator.

Parent Topic