This group includes messages for the Control-D, Control-D/Image, and Control-D/Page on Demand products.

SCD201I CONTROL-D SCHEDULER STARTED

Explanation: This information message indicates that the Control-D monitor internal scheduler task started.

Normal message when Control-D monitor is started.

Corrective Action: No action is required.

SCD202S INSUFFICIENT MEMORY FOR CONTROL-D MONITOR

Explanation: Insufficient memory for the initiation of Control-D monitor.

Control-D monitor will shut down.

Corrective Action: Increase the Control-D monitor region size.

SCD203I ELIGIBLE FOR PROCESSING

Explanation: This information message indicates that the mission has been given permission to run.

All the runtime conditions for mission execution have been met, and all the resources have been acquired for the mission. The mission will soon be executed by Control-D.

Corrective Action: No action is required.

SCD204E OUTPUT CONDITION condname_date NOT ADDED/ DELETED - SECURITY VIOLATION

Explanation: User is not authorized to add or delete the condition condname_date to or from the conditions file. The date is in mmdd format.

The mission definition contains an OUT statement or a DO COND statement (or both) for the referenced condition. The condition was not added or deleted because the user ID of the mission is not authorized to add or delete the condition.

Output condition is not added or deleted, but processing continues.

Corrective Action: Consult your INCONTROL administrator.

SCD208I PROCESSING ENDED "OK"

Explanation: This information message indicates that the mission finished executing OK.

Control-D determined that the mission ended OK because other events were marked OK in the mission’s parameters, and no other event was either unexplained or marked NOTOK.

Corrective Action: No action is required.

SCD218I RECYCLED FOR POSSIBLE REPROCESSING

Explanation: This information message indicates that the cyclic task was recycled for possible execution.

If all runtime conditions are met, the mission will be immediately eligible.

Corrective Action: No action is required.

SCD219I PROCESSING ENDED "NOT OK"

Explanation: This information message indicates that the Control-D monitor determined that the mission ended NOTOK.

The general Control-D message when a mission finishes executing NOTOK. The IOA Log should contain prior messages detailing the reasons.

Corrective Action: No action is required.

SCD220I missionType missionName WILL BE REPROCESSED

Explanation: This information message is issued because a manual request to rerun a mission was accepted.

The mission will be placed in WAIT SCHEDULE state again. If all runtime conditions are met, the mission will be started immediately.

Corrective Action: No action is required.

SCD229S OPEN FAILED FOR DDNAME "DARES"

Explanation: Open of a debugging output file failed (the DARES DD statement).

This is probably because the DARES DD statement is missing in the Control-D procedure.

The Control-D monitor will shut down with error message.

Corrective Action: Correct the JCL for the Control-D monitor procedure and start it again.

SCD230S OPEN FAILED FOR DDNAME "DARESC" OR "DASINC"

Explanation: Open of IOA Conditions file failed (the DARESC or DASINC DD statement).

Possible causes are:

Control-D monitor shuts down with error message.

Corrective Action: Correct the JCL for the Control-D procedure, and start the procedure again.

SCD231E REP Q23AREP1 MISSION IS NOT PROCESSED BECAUSE OF CONDITION ERROR

Explanation: The mission was not processed because an error which was detected for an IN condition. See the corresponding error message in Screen 5. The status of this condition is unknown and this mission is not processed, but processing continues.

Corrective Action: Consult your INCONTROL administrator.

SCD241W OUTPUT CONDITION cond_date NOT UPDATED - NO MORE SPACE. NOTIFY THE IOA ADMINISTRATOR

Explanation: Highlighted, unrollable message.

No more space to add output conditions to the conditions file. The date is in mmdd format.

The record for that specific day of the month is full. For example, if a condition with date reference of January 3rd cannot be added, an entry in the Conditions file that contains conditions for January 3rd, February 3rd, March 3rd, and so on, is full.

The condition is not added, and a highlighted message is displayed on the operator console. Control-D continues to function, but missions that depend on the condition are not submitted.

Corrective Action: Immediate action:

Long term action:

  1. You should run the IOACLCND Control-M utility more often.
  2. You may want to increase the record length of the IOA Conditions file. For more information on how to do this, see the section on expanding IOA files in the INCONTROL for z/OS Administrator Guide.

SCD249I SHUT DOWN UPON REQUEST OF MAIN TASK

Explanation: This information message announces the shutdown of the Control-D monitor.

Shutdown of Control-D internal selector task by request of Control-D main task.

The Control-D monitor will shut down.

Corrective Action: No action is required.