SARM40E {CA-View | CA-DISPATCH} CONVERSION - TAPE I/O ERROR text (78 chars max)

Explanation: An I/O error occurred while the report was being read from the archive tape.

Creation of the CDAM report file is halted.

Corrective Action: Analyze the message to determine the reasons for the I/O error. If possible, use external means for recovery. If recovery is completed successfully, run the restore job again.

SARM41E {CA-View | CA-DISPATCH} CONVERSION - REPORT NOT FOUND reportName, JOB: jobName (job_num), DATE: date, TIME: time

Explanation: The requested report could not be located in the tape.

The CA-VIEW (SAR) archive directory indicates that the report resides on a specific tape, but the report could not be located on that tape.

The restore request for the report is denied.

Corrective Action: Investigate the CA-VIEW (SAR) archive for potential corruption, or locate the report on other tapes.

SARM42E {CA-View | CA-DISPATCH} CONVERSION - COULD NOT OPEN TAPE WITH FILE dsn

Explanation: The report restore program could not open the tape that hold the archive reports.

The CA-VIEW (SAR) archive directory indicates that the report resides on a specific tape, but the report could not be located on that tape.

The request to restore the report is denied.

Corrective Action: Investigate the CA-VIEW (SAR) archive for potential corruption, verify that the tape is not damaged, or locate the report on other tapes.

SARM43E {CA-View | CA-DISPATCH} CONVERSION - COULD NOT CREATE CDAM DATASET

Explanation: The restore report could not be written to the CDAM subsystem.

An error occurred while the report was being restored to a CDAM file.

The request to restore the report is terminated.

Corrective Action: Check the CDAM subsystem and its allocation parameters to ensure that the CDAM subsystem can accept new files.

SARM44E {CA-View | CA-DISPATCH} CONVERSION - CDAM FILE dsn CREATED

Explanation: This information message indicates that a CDAM file was successfully created to satisfy the restore request.

The restored report is ready for insertion in the Active User Reports file.

Note:

Although the message code ends with E, this message does not indicate that an error occurred.

Corrective Action: No action is required.

SARM45E INFOPAC CONVERSION - REPORT NOT FOUND reportName, FILE: dsn

Explanation: The report that was requested cannot be located on the tape.

The RESTORE request for the report is rejected.

Corrective Action: Do the following:

  1. Check if the correct INFOPAC archive volume was mounted.
  2. If the correct tape was mounted, examine the tape for possible corruption.