Messages MTO200 through MTO2xx

This group includes messages for the Control-O product.

MTO272I CTOJFRQ EXIT POINT SUCCESSFULLY REMOVED

Explanation: This information message indicates that as part of its termination process, the Control-O monitor successfully disabled and removed the dynamic exit IEFJFRQ that uses the CTOJFRQ module. Control-O uses the CTOJFRQ module for ON SYSOUT and JES2 command suppression functions.

Corrective Action: No action is required.

MTO273W CTOJFRQ EXIT POINT NOT REMOVED RC = rc REASON CODE = rsn

Explanation: Upon termination, the Control-O monitor has failed to disable and remove the dynamic exit IEFJFRQ that uses the CTOJFRQ module. Control-O uses the CTOJFRQ module for ON SYSOUT and JES2 command suppression function.

Control-O terminates without removing the dynamic exit IEFJFRQ that uses the CTOJFRQ module. This may cause an S0C4 code in various jobs under the subsystem interface. In this case, MVS automatically disables the dynamic exit IEFJFRQ that uses the CTOJFRQ module.

Corrective Action: Inform the system programmer, and check the return code and reason code of the CSVDYNEX macro in the IBM manual MVS Programming: Authorized Assembler Services Reference.

MTO274E ERROR WHILE LOADING CTOJFRQ EXIT POINT

Explanation: When Control-O monitor started, it failed to load and enable the dynamic exit IEFJFRQ that uses the CTOJFRQ module. Control-O uses the CTOJFRQ module for ON SYSOUT and JES2 command suppression function.

Control-O starts without enabling the dynamic exit IEFJFRQ that uses the CTOJFRQ module. As a result, ON SYSOUT and JES2 command suppression functions will not be active.

Corrective Action: Inform your system programmer.

MTO275E CTOJFRQ EXIT POINT NOT INSTALLED RC = rc REASON CODE= rsn

Explanation: When the Control-O monitor started, it failed to load and activate the IEFJFRQ dynamic exit, which uses the CTOJFRQ module. Control-O uses the CTOJFRQ module for ON SYSOUT and JES2 command suppression function.

Control-O starts without enabling the IEFJFRQ dynamic exit that uses the CTOJFRQ module. As a result, ON SYSOUT and JES2 command suppression functions will not be active.

Corrective Action: Inform your system programmer and check the RC and REASON CODE of the CSVDYNEX macro in the IBM OS/390 Authorized Macros and Services Guide.

MTO276I CTOJFRQ EXIT POINT SUCCESSFULLY INSTALLED

Explanation: This information message indicates that when the Control-O monitor started, it successfully enabled the dynamic exit IEFJFRQ that uses the CTOJFRQ module. Control-O uses the CTOJFRQ module for ON SYSOUT and JES2 command suppression function.

Corrective Action: No action is required.

Parent Topic

MTO messages