Previous Topic

Next Topic

Book Contents

Book Index

Messages IOA600 through IOA6xx

This group includes messages for the IOA (infrastructure) product.

IOA631S INVALID FORMAT OF INPUT PARAMETERS

Explanation: While the IOA Online facility was being initialized, a severe syntax error was found in one of the keywords in one of the ALC members. ALC members contain keywords that reference data sets to be allocated during initialization. The line in which the erroneous keyword appears is displayed in the IOAD81I message that follows this message.

IOA Online facility terminates with errors.

Corrective Action: Correct the erroneous keyword displayed in message IOAD81I, and reactivate the IOA Online facility.

IOA684E DSN dsn IN USE (DISP=OLD)

Explanation: The dsn data set is held exclusively by another user.

Possible causes are:

The system action depends on the cause, as follows:

Corrective Action: Try again.

IOA686E DSN dsn NOT IN CATALOG

Explanation: The requested data set name is not in the catalog.

Possible causes are:

The system action depends on the cause, as follows:

Corrective Action: The appropriate response depends on the cause, as follows:

  1. AutoEdit facility - correct the JCL for the job and rerun it.
  2. Online facility - correct the library name and retry.
  3. New Day procedure - correct the New Day procedure and retry.

Parent Topic

IOA messages