Previous Topic

Next Topic

Book Contents

Book Index

Messages IOA100 through IOA1xx

This group includes messages for the IOA (infrastructure) product.

IOA100I srvr - IOA ARCHIVE SERVER INITIALIZATION STARTED

Explanation: This information message indicates that the IOA Archive Server has started and is currently building the required internal environment.

Corrective Action: No action is required.

IOA101E srvr - IOA ARCHIVE SERVER INITIALIZATION FAILED RC rc IN STEP step

Explanation: The IOA Archive Server encountered an internal error.

The cross-memory environment could not be established.

The IOA Archive Server shuts down.

Corrective Action: Activate the Control-D subsystem. If it is already active, deactivate then reactivate it. Try to reactivate the IOA Archive server. If this does not help, check for other system messages that might clarify the cause of the problem and precede accordingly. If these measures are of no avail, record the return code, step name and all other related messages and contact BMC Customer Support.

IOA102E srvr - IOA ARCHIVE SERVER NOT APF-AUTHORIZED

Explanation: The IOA Archive Server is not APF (Authorized Programming Facility) authorized. The IOASSRV module is not in an APF authorized library or does not have attribute AC=1.

The IOA Archive Server terminates with a return code of 8.

Corrective Action: Add the name of the library in which the IOASSRV module resides to the IEAAPF00 member in the SYS1.PARMLIB library.

IOA103E srvr - COMMAND FAILED - cmdText

Explanation: An invalid command or parameter was passed to the IOA Archive Server by an operator MODIFY command. This message is accompanied by another message that indicates why the command failed.

The MODIFY command is not executed.

Corrective Action: See the accompanying message, which indicates why the command failed.

IOA104S srvr BLDL/LOAD FAILED FOR THE MODULE modName

Explanation: Loading of the modName module failed. Possible causes are:

The IOA Archive Server terminates with a return code of 8.

Corrective Action: Check the system job log for more information. If the problem persists, contact BMC Customer Support.

IOA105S srvr - UNRECOVERABLE ERROR ENCOUNTERED

Explanation: An unrecoverable error occurred in the operation of the IOA Archive Server.

The IOA Log file should contain a previous message about the error.

The IOA Archive Server shuts down.

Corrective Action: Check the accompanying message in the IOA Log file. Contact your system programmer for assistance. If the problem is not resolved, contact BMC Customer Support.

IOA106S srvr - MEDIA mediaName HAS ABENDED

Explanation: An IOA Archive Server internal subtask abended.

The IOA Log file and system log should contain previous messages about this error.

The IOA Archive Server issues an implicit START command for this media. Attempts are made to initialize media mediaName and continue normal processing. If these attempts fail, the IOA Archive Server sets the status of the abended media to never active and this media becomes unavailable for use by the IOA Archive Server.

Corrective Action: Check the IOA Log file and system log for additional messages which may indicate why media mediaName abended. If the problem is not resolved, contact BMC Customer Support.

IOA107I srvr - SHUT DOWN UPON REQUEST FROM OPERATOR

Explanation: This information message indicates that the IOA Archive Server is shutting down upon operator’s request.

Corrective Action: No action is required.

IOA108E srvr - REASON: COMMAND IS INVALID

Explanation: An invalid command was passed to the IOA Archive Server. This message follows message IOA103E or SRV103E, which contains the text of the failed command.

The MODIFY command is not executed.

Corrective Action: For more information, refer to the section that describes the IOA Archive Server in the Control-D and Control-V User Guide. Enter a valid MODIFY command.

IOA109S srvr - MEDIA TYPE media_type IS INVALID OR NOT SUPPORTED

Explanation: The IOA Archive Server encountered an invalid or unsupported media type specified in the IOASPRM member (IOA Archive Server Installation Parameters).

The media type specified in the IOASPRM member should match one of the supported media types specified in the IOA Archive Server Program List (the IOASPROG member).

The IOA Archive Server terminates with a return code of 8.

Corrective Action: For more information about currently supported media types, refer to the section on how to set IOA Archive Server Installation Parameters in the INCONTROL for z/OS Installation Guide. Correct the media_type in the IOASPRM member (IOA Archive Server Installation Parameters). Start the IOA Archive Server again. If the problem is not resolved, contact BMC Customer Support.

IOA10AS srvr - SERVER NAME IS NOT EQUAL TO THE PROCNAME SPECIFIED IN IOASPRM

Explanation: Highlighted, unrollable message.

The name of IOA Archive Server does not match the value of the PROCNAME parameter in the IOASPRM member. The name of the IOA Archive Server must be the same as the value of the PROCNAME IOA Archive Server Installation Parameter in the IOASPRM member.

The IOA Archive Server terminates with a return code of 8.

Corrective Action: Use the correct IOA Archive Server name or correct the value of the PROCNAME parameter. Restart the IOA Archive Server.

IOA10BI srvr - IOA ARCHIVE SERVER SHUTTING DOWN

Explanation: Highlighted, unrollable message.

This information message indicates that the IOA Archive Server is shutting down due to operator command or due to internal events.

The IOA Log file should contain additional messages about the reason for shutting down the IOA Archive Server.

The IOA Archive Server shuts down.

Corrective Action: No action is required.

IOA10CS srvr - IOA ARCHIVE SERVER ENDED WITH ERROR

Explanation: An error caused the IOA Archive Server to terminate. The IOA Log file and system log file should contain additional messages identifying the specific error.

The IOA Archive Server shuts down.

Corrective Action: Check the IOA Log file and the system log for the reason. Contact your system programmer for assistance if needed.

IOA10DW srvr - YOUR IOA ARCHIVE SERVER IS ALREADY ACTIVE. QNAME qName

Explanation: Highlighted, unrollable message.

An attempt was made to start an IOA Archive Server which is already active. It is impossible to run two IOA Archive Servers with the same qName at the same time.

The newly-started IOA Archive Server with the same qName shuts down.

Corrective Action: No action is required.

IOA10EE srvr - REASON: PARAMETER IS INVALID

Explanation: An invalid parameter was passed to the IOA Archive Server by operator command MODIFY. This message follows the IOA103E or SRV103E message, which indicates that operator command MODIFY failed and contains the text of the failed command.

The MODIFY command is not executed.

Corrective Action: For more details, refer to the section that describes the IOA Archive Server in the Control-D and Control-V User Guide. Reissue the MODIFY command with valid parameters.

IOA110E srvr - INSUFFICIENT STORAGE FOR INITIALIZATION RC=rc

Explanation: There is insufficient memory to initiate or operate the IOA Archive Server.

The IOA Archive Server shuts down.

Corrective Action: Increase the IOA Archive Server REGION size. If the problem persists, record the return code and contact BMC Customer Support.

IOA114S srvr - BLDL/ATTACH FAILED FOR MODULE modName

Explanation: Initialization of an IOA Archive Server internal task failed.

Possible causes are:

The IOA Archive Server terminates.

Corrective Action: Check the system log for additional messages which clarify the situation. Try one of the following:

IOA115E srvr - OPEN OF DDNAME ddName FAILED

Explanation: Open of the ddName DD statement failed.

Possible causes are:

The IOA Archive Server terminates with a return code of 8.

Corrective Action: Correct the JCL and rerun the job.

IOA116W srvr - ALL MEDIA ARE INACTIVE

Explanation: Highlighted, unrollable message.

The IOA Archive Server issues this message when it determines that no active media are allocated to it.

Every media was terminated due to operator request or internal error. This message disappears when a START command is issued for any media.

The IOA Archive Server continues processing.

Corrective Action: If information about the status of a media is needed, issue a DISPLAY command.

IOA117I srvr - IOA ARCHIVE SERVER INITIALIZATION COMPLETE

Explanation: This information message indicates that the IOA Archive Server was successfully initialized.

Corrective Action: No action is required.

IOA118E srvr - REASON: MEDIA mediaName IS INCORRECT

Explanation: The media was specified in a MODIFY operator command, but was not defined in the IOASPRM member, which defines the IOA Archive Server Installation Parameters. This message follows message IOA103E or SRV103E, which indicates that operator command MODIFY failed and contains the text of the failed command.

The MODIFY command is not executed.

Corrective Action: For more details, refer the section that describes the IOA Archive Server in the Control-D and Control-V User Guide. Reissue the MODIFY command with the correct media name.

IOA11AE srvr - REASON: MEDIA mediaName ALREADY INACTIVE

Explanation: An attempt was made to stop media mediaName which was already inactive. This message follows message IOA103E or SRV103E, which indicates that operator command MODIFY failed and contains the text of the failed command.

The MODIFY command is not executed.

Corrective Action: No action is required.

IOA11BE srvr - REASON: MEDIA mediaName ALREADY ACTIVE

Explanation: An attempt was made to start media mediaName which was already active. This message follows message IOA103Eor SRV103E, which indicates that operator command MODIFY failed and contains the text of the failed command.

The MODIFY command is not executed.

Corrective Action: No action is required.

IOA11CE srvr - INITIALIZATION OF ALL MEDIA FAILED

Explanation: During initialization, the IOA Archive Server determined that initialization failed for all media specified in the IOASPRM member (IOA Archive Server Installation Parameters).

Every media was terminated due to an unrecoverable error. The IOA Log file should contain additional messages concerning specific errors.

The IOA Archive Server terminates with a return code of 8.

Corrective Action: Check the IOA Log file and the system log for messages describing the error. Contact the system programmer for assistance if needed. Start the IOA Archive Server again. If the problem is not resolved, contact BMC Customer Support.

IOA11DW srvr - nn CYCLES PERFORMED WHILE WAITING FOR MEDIA INITIALIZATION TO BE COMPLETED

Explanation: Highlighted, unrollable message.

The IOA Archive Server cannot complete the initialization phase. During IOA Archive Server initialization, a period of time equal to nn cycles elapsed before any media specified for use by the IOA Archive Server completed the initialization process. Each cycle is one IOA Archive Server sleeping interval, whose value in hundredths of a second is defined in the INTERVAL parameter in the IOASPRM member in the IOA Archive Server Installation Parameters.

The initialization of the IOA Archive Server is not completed.

Corrective Action: Check the IOA Log file and the system log for the cause of the problem. If the IOA Archive Server waits a long time for media to complete initialization, and the reason for the delay cannot be determined, issue the CANCEL command to stop the IOA Archive Server. Restart the IOA Archive Server. If the problem is not resolved, contact BMC Customer Support.

IOA11EW srvr - nn CYCLES PERFORMED WHILE WAITING FOR MEDIA TO TERMINATE

Explanation: The IOA Archive Server cannot complete the termination phase. During IOA Archive Server termination, a period of time equal to nn cycles elapsed before the media specified for use by the IOA Archive Server completed the termination process. Each cycle is one IOA Archive Server sleeping interval, whose value in hundredths of a second is defined in the INTERVAL parameter in the IOASPRM member in the IOA Archive Server Installation Parameters.

The termination of the IOA Archive Server is not completed.

Corrective Action: Check the IOA Log file and the system log for the cause of the problem. If the IOA Archive Server waits a long time for media to complete termination, and the reason for the delay cannot be determined, issue operator command CANCEL to stop the IOA Archive Server. If the problem is not resolved, contact BMC Customer Support.

IOA11FW srvr - REASON: MEDIA mediaName IS BUSY

Explanation: A command cannot be passed to media mediaName for execution because the media has not finished executing a previous command. This message follows message IOA103E or SRV103E, which indicates that operator command MODIFY failed and contains the text of the failed command.

The MODIFY command is not executed.

Corrective Action: Reissue the MODIFY command later.

IOA120S srvr - INTERNAL ERROR RC=rc

Explanation: The IOA Archive Server encountered an internal error.

The IOA Archive Server terminates with abend code 0006. The output includes a dump of the abend.

Corrective Action: Report the message ID and return code to BMC Customer Support.

IOA121E srvr - REASON: MEDIA mediaName INACTIVE

Explanation: An attempt was made to start a device assigned to media mediaName while that media was inactive. Media mediaName must be started before issuing a START command for a device assigned to it. This message follows message IOA103E or SRV103E, which indicates that operator command MODIFY failed and contains the text of the failed command.

The MODIFY command is not executed.

Corrective Action: Issue an operator command to start media mediaName, as follows: F IOASMON,START MEDIA=mediaName

After media mediaName is initialized successfully, issue the MODIFY command to start a device. For more details, refer to the section that describes the IOA Archive Server in the Control-D and Control-V User Guide.

IOA122W srvr - IOA ARCHIVE SERVER PARAMETERS CONTAIN NO MEDIA OR ONLY MEDIA TYPE DASD

Explanation: During the initialization phase, the IOA Archive Server determined that the IOASPRM member does not include a definition for any media or only includes definitions for media of the DASD type. Possible causes are:

Do not activate the IOA Archive Server unless a media type other than DASD is defined in the IOASPRM member.

The IOA Archive Server shuts down.

Corrective Action: If the services of the IOA Archive Server are required, add appropriate media to the IOASPRM member in the IOA Archive Server Installation Parameters, and restart the IOA Archive Server.

IOA123W cdam_srvr_name - GETMAIN FAILED DURING SESSION OPENING OF USER userId

Explanation: An attempt to access a migrated index failed because there is insufficient memory in the IOA Archive server to open a session. A session is opened in the IOA Archive server when accessing a migrated index. This error occurs when there is not enough memory in the IOA Archive server to hold the RBA range table of the user, and the index record for that index.

The session is not opened and the migrated index cannot be viewed.

Corrective Action: Increase the region of the IOA Archive server.

IOA124W cdam_srvr_name - OSE TYPE PASSED TO SERVER BY USERID userId IS INVALID

Explanation: An internal error occurred when accessing a migrated index. A session is opened in the IOA Archive Server when accessing a migrated index.

The session is not opened and the migrated index cannot be viewed.

Corrective Action: Print the user record and index records of the report. Record the last actions of the user before the error occurred. Supply this information to BMC Customer Support.

IOA127E srvr - DEBUG LEVEL MUST BE A NUMBER BETWEEN 0-255

Explanation: The MODIFY operator command to activate the IOA Archive Server debug facility contains an invalid DEBUG level. Valid DEBUG levels are between 0 and 255. Zero specifies no debugging.

The MODIFY command is not executed. The DEBUG facility is not activated.

Corrective Action: Reissue the operator command with the correct debug level. The required debugging level should be supplied by BMC Customer Support.

IOA128I srvr - DEBUG LEVEL IS SET TO lvl

Explanation: This information message indicates that the IOA Archive Server debug level has been set to nnn by a MODIFY operator command.

Each debug level activates the trace option on different components of the IOA Archive Server.

The DEBUG level is set to level nnn.

Corrective Action: No action is required.

IOA130E mediaName - REASON: DEVICE deviceId IS NOT ASSIGNED TO THIS MEDIA

Explanation: An attempt was made to reference device deviceId, which currently is not assigned to media mediaName. This message follows message IOA137E or MDT137E, which indicates that operator command MODIFY failed and contains the text of the failed command.

The MODIFY command is not executed.

Corrective Action: For more details, refer to the section that describes the IOA Archive Server in the Control-D and Control-V User Guide. Issue a DISPLAY command to obtain information about each media and its resources that are known to the IOA Archive Server. Reissue the MODIFY operator command with the correct deviceId number.

IOA131E mediaName - REASON: DEVICE deviceId ALREADY INACTIVE

Explanation: An attempt was made to stop device deviceId, which is currently inactive. This message follows message IOA137E or MDT137E, which indicates that operator command MODIFY failed and contains the text of the failed command.

The MODIFY command is not executed.

Corrective Action: No action is required.

IOA132E mediaName - REASON: DEVICE deviceId ALREADY ACTIVE

Explanation: An attempt was made to start device deviceId, which is currently active. This message follows message IOA137E or MDT137E, which indicates that operator command MODIFY failed and contains the text of the failed command.

The MODIFY command is not executed.

Corrective Action: No action is required.

IOA133W mediaName - nn CYCLES PERFORMED WHILE WAITING FOR MEDIA INITIALIZATION TO BE COMPLETED

Explanation: Highlighted, unrollable message.

Media mediaName cannot complete the initialization phase.

During initialization, the media waits for devices which have been started to complete their initialization process. No responses were received from these devices. Each “cycle” is one IOA Archive Server sleeping interval whose value (in hundredths of a second) is defined in the INTERVAL parameter in the IOASPRM member in the IOA Archive Server Installation Parameters.

The initialization of media mediaName is not completed.

Corrective Action: Check the IOA Log file and the system log for the cause of the problem. If media mediaName waits a long time for devices to complete initialization and the reason for the delay cannot be determined, issue a CANCEL operator command to stop the IOA Archive Server. Start the IOA Archive Server again. If the problem is not resolved, contact BMC Customer Support.

IOA134E mediaName - MEDIA SHUT DOWN - INITIALIZATION OF ALL DEVICES FAILED

Explanation: The initialization process for all devices assigned to media mediaName failed.

Media mediaName is terminated and becomes unavailable for use by the IOA Archive Server.

Corrective Action: Check the IOA Log file and system log for messages about the initialization failure. Issue an operator command to restart media mediaName. If the problem is not resolved, contact BMC Customer Support.

IOA135W mediaName - nn CYCLES PERFORMED WHILE WAITING FOR DEVICE TO TERMINATE

Explanation: Highlighted, unrollable message.

Media mediaName cannot complete the termination phase.

During termination, media mediaName waits for devices to terminate. Each “cycle” is one IOA Archive Server sleeping interval whose value (in hundredths of a second) is defined in the INTERVAL parameter in the IOASPRM member in the IOA Archive Server Installation Parameters.

The termination of media mediaName is not completed.

Corrective Action: Check the IOA Log file and the system log for the cause of the problem. If media mediaName waits a long time for devices to complete termination and the reason for the delay cannot be determined, issue a CANCEL operator command stop the IOA Archive Server. If the problem is not resolved, contact BMC Customer Support.

IOA136E mediaName - REASON: LENGTH OF DEVICE NUMBER IN DEVICE= deviceId IS INCORRECT

Explanation: The DEVICE parameter was specified with an invalid length. The length of the DEVICE parameter in the MODIFY operator command should be four digits.

This message follows message IOA137E or MDT137E, which indicates that operator command MODIFY failed and contains the text of the failed command.

The MODIFY command is not executed.

Corrective Action: Reissue the MODIFY command with a correct DEVICE parameter.

IOA137E mediaName - COMMAND FAILED cmdText

Explanation: An invalid command or parameter was passed to media mediaName by a MODIFY operator command. This message is followed by other messages that clarify why the operator command failed.

The MODIFY command is not executed.

Corrective Action: Check the system log for a message that indicates why the command failed. Correct the problem, and reissue the MODIFY operator command.

IOA138E mediaName - REASON: PARAMETER IS INVALID

Explanation: An invalid parameter was passed to media mediaName by the MODIFY operator command. This message follows message IOA137E or MDT137E, which indicates that operator command MODIFY failed and contains the text of the failed command.

The MODIFY command is not executed.

Corrective Action: For more information, refer to the section on the IOA Archive Server in the Control-D and Control-V User Guide. Enter a MODIFY command with valid parameters.

IOA139I mediaName - MEDIA SHUT DOWN UPON REQUEST FROM OPERATOR

Explanation: This information message indicates that media mediaName is shutting down upon the operator’s request.

Corrective Action: No action is required.

IOA13AI mediaName - MEDIA SHUT DOWN UPON REQUEST OF MAIN TASK

Explanation: This information message indicates that media mediaName is shutting down upon the IOA Archive Server’s request.

Possible causes are:

The IOA Archive Server shuts down the media before it shuts down. The IOA Log file and system log should contain additional messages concerning the situation.

Media mediaName shuts down.

Corrective Action: Check the IOA Log file and system log for messages explaining the situation. Contact the system programmer for assistance, if needed.

IOA13BE mediaName - REASON: VALUE SPECIFIED IN DEVICE= PARAMETER IS INVALID

Explanation: The DEVICE parameter was specified in a modify operator command without specifying its value. This message follows message IOA137E or MDT137E, which indicates that the modify operator command failed, and contains the text of the failed command.

MODIFY is not executed.

Corrective Action: For more information, refer to the section on the IOA Archive Server in the Control-D and Control-V User Guide. Reissue the MODIFY command with a valid DEVICE parameter.

IOA13DE mediaName - REASON: DEVICE= PARAMETER IS INVALID FOR DYNAMIC DEVICES

Explanation: An attempt to start a specific device by operator command failed because the devices used by the IOA Archive Server are allocated dynamically. This message follows message IOA137E/MDT137E, which indicates that operator command MODIFY failed and contains the text of the failed command.

MODIFY is not executed.

Corrective Action: For more information about how to control the device, refer to the section on media and resource management in the Control-D and Control-V User Guide. Reissue the MODIFY command with appropriate parameters.

IOA13FW mediaName - REASON: ALL DEVICES ARE ALREADY ACTIVE

Explanation: An attempt to start one or more devices by issuing a MODIFY operator command failed, because all devices were already active.

This message follows message IOA137E or MDT137E, which indicates that operator command MODIFY failed and contains the text of the failed command. The operator cannot increase the number of devices the IOA Archive Server can use to more than the maximum quantity defined in the IOASPRM member in the IOA Archive Server Installation Parameters.

The MODIFY command is not executed.

Corrective Action: Issue a DISPLAY command to get information about each media and its resources that are allocated to the IOA Archive Server. For more information about how to control devices, refer to the section on media and resource management in the Control-D and Control-V User Guide.

IOA140S mediaName - BLDL/ATTACH/LOAD FAILED FOR THE MODULE modName

Explanation: Initialization of the mediaName media failed.

Possible causes are:

The IOA Archive Server shuts down.

Corrective Action: Check the system log for additional messages which clarify the situation. Try one of the following:

IOA141I mediaName - INITIALIZATION STARTED

Explanation: This information message indicates that media mediaName has started and is building the required internal environment.

Corrective Action: No action is required.

IOA142I mediaName - INITIALIZATION SUCCESSFULLY COMPLETED

Explanation: This information message indicates that media mediaName was successfully initialized.

Corrective Action: No action is required.

IOA143W mediaName - REASON: ALL DEVICES ARE ALREADY INACTIVE

Explanation: An attempt to stop one or more devices by issuing a MODIFY operator command failed, because all the devices were already inactive. This message follows message IOA137E, which indicates that operator command MODIFY failed and contains the text of the failed command.

The MODIFY command is not executed.

Corrective Action: For more information, refer to the section on the IOA Archive Server in the Control-D and Control-V User Guide. Issue a DISPLAY command to get information about each media and its resources that are allocated to the IOA Archive Server.

IOA144S mediaName - INSUFFICIENT STORAGE FOR INITIALIZATION

Explanation: Highlighted, unrollable message.

Insufficient memory is available to initiate media mediaName.

Media mediaName shuts down. The IOA Archive Server shuts down.

Corrective Action: Increase the IOA Archive Server REGION size.

IOA145E mediaName - FREEMAIN ERROR ENCOUNTERED

Explanation: Highlighted, unrollable message.

Media mediaName encountered an internal error.

The media mediaName task terminates with User Abend 0007. The IOA Archive Server terminates with User Abend code 0006. The output includes a dump of the abend.

Corrective Action: Contact your system programmer for assistance. If the problem is not resolved, contact BMC Customer Support.

IOA146E mediaName - MEDIA INITIALIZATION FAILED

Explanation: Highlighted, unrollable message.

Media mediaName encountered an internal error.

This message is preceded by other messages which clarify the situation.

Media mediaName shuts down.

Corrective Action: Check the IOA Log file and the system log for messages describing the error. Contact your system programmer for assistance, if needed. If the problem is not resolved, contact BMC Customer Support.

IOA147S mediaName - INTERNAL ERROR DURING INITIALIZATION - MEDIA INITIALIZATION FAILED

Explanation: Highlighted, unrollable message.

The mediaName media encountered an internal error.

The mediaName media abends with User Abend 0007. The IOA Archive Server shuts down with User Abend 0006. The output includes a dump of the abend.

Corrective Action: Contact your system programmer for assistance. If the problem is not resolved, contact BMC Customer Support.

IOA148S mediaName - INTERNAL ERROR RC=rc

Explanation: Media mediaName encountered an internal error.

One of the following actions occurs, depending on severity of the internal error:

Corrective Action: Check the IOA Log file and system log for messages describing the error. Contact your system programmer for assistance. If the problem is not resolved, report the rc to BMC Customer Support.

IOA149E mediaName - REASON: COMMAND IS INVALID

Explanation: An invalid command was passed to media mediaName by the MODIFY operator command. This message follows message IOA137E or MDT137E, which indicates that operator command MODIFY failed and contains the text of the failed command.

The MODIFY command is not executed.

Corrective Action: For more information, refer to the section on the IOA Archive Server in the Control-D and Control-V User Guide. Enter a valid MODIFY command.

IOA14AE mediaName - REASON: VALUE SPECIFIED IN DEVQTY= PARAMETER IS INVALID

Explanation: An invalid value was specified for the DEVQTY parameter. This message follows message IOA137E or MDT137E, which indicates that operator command MODIFY failed and contains the text of the failed command. Possible causes are:

The MODIFY command is not executed.

Corrective Action: For more information, refer to the section on the IOA Archive Server in the Control-D and Control-V User Guide. Issue a DISPLAY command to get information about each media and its resources that are allocated the IOA Archive Server. Reissue the MODIFY command with a valid DEVQTY parameter.

IOA14BE mediaName - LOCATE ERROR FOR dsn RC=rc

Explanation: A CDAM data set cannot be found in the catalog.

The user requested a report which resides on a CDAM file which is uncataloged or does not exist.

The request is ignored.

Corrective Action: Catalog the file or take other corrective action and try again.

IOA14CI mediaName - MEDIA SHUTTING DOWN

Explanation: This information message indicates that media mediaName is shutting down.

Corrective Action: No action is required.

IOA14DS mediaName - DEVICE deviceId ABENDED

Explanation: A media internal subtask abended.

Media mediaName issues an implicit start command for device deviceId. Attempts are made to initialize this device and continue normal processing. If these attempts fail, media mediaName sets the status of the designated device to NEVER ACTIVE and this device becomes unavailable for use by the IOA Archive Server.

Corrective Action: Check the IOA Log file and system log for additional messages which indicate why device deviceId abended.

IOA14ES mediaName - PARAMETER DEVADDR NUMBER nnnn DEFINED IN IOASPRM INSTALLATION PARAMETERS IS INVALID

Explanation: The DEVADDR parameter contains an invalid value.

The format of the device number specified in the DEVADDR parameter in the IOASPRM member (IOA Archive Server Installation Parameters) must be four digits.

Initialization of media mediaName fails. The IOA Archive Server shuts down with a return code of 08.

Corrective Action: Set the DEVADDR parameter to a valid numeric value and restart the IOA Archive Server.

IOA14FI mediaName - ALL DEVICES WERE DEFINED AS INACTIVE IN IOASPRM INSTALLATION PARAMETERS

Explanation: This information message indicates that mediaName is inactive because all devices which belong to it are defined as inactive in the IOASPRM member (IOA Archive Server Installation Parameters).

Corrective Action: If necessary, issue operator MODIFY commands to start the media and the devices.

IOA150E mediaName - DYNAMIC ALLOCATION ERROR FOR DDNAME=SORTIN RC=rc, REASON CODE=rsn

Explanation: An error occurred while trying to allocate an OSS Extract Database file.

This error causes the dynamic allocation of the SORTIN DD statement to fail.

For information on the return code (rc), see the IBM manual MVS Programming: Authorized Assembler Services Guide.

Media mediaName is terminated.

Corrective Action: Use the return code (rc) and reason code (rsn) to determine the problem and correct it. If you cannot re solve the problem, record the DD statement, return code, and reason code, and contact BMC Customer Support.

IOA151S sort_prog - SORT OF OSS EXTRACT DATABASE FILE FAILED, RC=rc

Explanation: The internal sort of the OSS Extract Database file failed.

In this message, sort_prog activates the regular sort program at the site.

The system log usually contains additional messages about specific errors.

sort_prog is terminated.

Corrective Action: Check the system log for messages describing the error. Contact the system programmer for assistance, if needed. If the problem is not resolved, contact BMC Customer Support.

IOA170I mediaName - DEVICE deviceId - IS STARTING

Explanation: This information message indicates that IOA Archive Server deviceId device allocated to the mediaName media started.

Corrective Action: No action is required.

IOA171I mediaName - DEVICE deviceId - SHUT DOWN UPON REQUEST OF MAIN TASK

Explanation: This information message indicates that the main task requested shutting down the IOA Archive Server deviceId device allocated to the mediaName media.

Corrective Action: No action is required.

IOA17AI mediaName - DEVICE deviceId - UNABLE TO ALLOCATE DEDICATED DEVICE

Explanation: This information message indicates that the IOA Archive Server could not allocate device deviceId even though it is dedicated to the Server explicitly by means of the DEVADDR parameter or implicitly by a quantity of a unit name in the DEVQTY parameter.

If dedicated explicitly, the device possibly is disconnected.

If dedicated implicitly, probably no device in the device group specified in the IOASPRM member for mediaName media is available.

See messages DVT190E or IOA190E and DVT192E or IOA192E in the IOA Log file for the error code and info code.

The Server tries to allocate the device at 3-minute intervals until stopped by a MODIFY command.

Corrective Action: Use the error code and information code to determine why the allocation failed. For a description of the return code, see the IBM manual MVS Programming: Authorized Assembler Services Guide. Ask the operator to correct the problem and restart the device.

IOA17BI mediaName - DEVICE deviceId - UNABLE TO ALLOCATE DEVICE DYNAMICALLY

Explanation: This information message indicates that the IOA Archive Server could not allocate the deviceId device which should be allocated dynamically. Probably none of the devices in the device group specified in the IOASPRM member for the mediaName media is available.

For the error code and information code, see the DVT190E or IOA190E and DVT192E or IOA192E messages in the IOA Log file. For a description of the return code, see the IBM manual MVS Programming: Authorized Assembler Services Guide.

The Archive Server tries to allocate the device five times, at 2-minute intervals. If it does not succeed, device deviceId is terminated.

Corrective Action: Use the error code and information code to determine why the allocation failed. Ask the operator to correct the problem and restart the device.

IOA17CI mediaName - DEVICE deviceId - SHUT DOWN BECAUSE OF INTERNAL ERROR

Explanation: Highlighted, unrollable message.

This message indicates that an internal error occurred while accessing device deviceId.

The cache request that generated the error is ignored. The activity that used this device is restarted.

Corrective Action: Notify your INCONTROL administrator.

IOA17DI mediaName - DEVICE deviceId - SHUT DOWN BECAUSE OF ABEND Snnn

Explanation: Highlighted, unrollable message.

This message indicates that an abend occurred while accessing the deviceId device.

The cache request which caused the abend is ignored. The activity which used this device will be restarted.

Corrective Action: Notify your INCONTROL administrator.

IOA180S mediaName - DEVICE deviceId - UNABLE TO ACQUIRE STORAGE FOR blockId, RC IS rc

Explanation: IOA Archive Server device deviceId is unable to acquire storage space for a BLKLST, FDB, CMP, CACHE or RDBUF block. See accompanying message DVT178I or IOA178I for the name of the requested file.

Execution of the task on device deviceId is terminated.

Corrective Action: Restart the IOA Archive Server. Re-IPL if necessary. Notify your INCONTROL administrator.

IOA181S mediaName - DEVICE deviceId - UNABLE TO xxQ ON vol / platter / device, RC IS rc

Explanation: The IOA Archive Server for device deviceId was unable to ENQ or DEQ on a key volume, platter, or device.

Execution of the task on device deviceId is terminated.

Corrective Action: Restart the IOA Archive Server. Re-IPL if necessary. Notify your INCONTROL administrator.

IOA190E mediaName - DEVICE deviceId - UNABLE TO ALLOCATE UNIT unit

Explanation: A file could not be dynamically allocated on mediaName media by the deviceId IOA Archive Server device.

For the error code and info code, see message DVT192E or IOA192E. For information on these codes, see the IBM manual MVS Programming: Authorized Assembler Services Guide.

The request is ignored.

Corrective Action: Use the error code and info code to determine why the allocation failed. Correct the problem. Restart the IOA Archive Server.

IOA191E mediaName - DEVICE deviceId - UNABLE TO DEALLOCATE

Explanation: The specified file could not be deallocated on the specified media when switching to another file in the IOA Archive Server device task.

For the error code and info code, see message DVT192E or IOA192E.

The next request and all future requests are ignored until deallocation succeeds.

Corrective Action: Use the error code and info code to determine why deallocation failed. Correct the problem. Restart the IOA Archive Server.

IOA192E mediaName - DEVICE deviceId - ERR + INFO CODE IS err+info_code

Explanation: This message accompanies messages IOA190E or DVT190E and IOA191E or DVT191E. It provides the error code and info code for a failed dynamic allocation or deallocation.

Corrective Action: Use the error code and info code to determine the problem and correct it.

IOA193E mediaName - DEVICE deviceId - I/O ERROR error

Explanation: The I/O error identified in this message occurred.

The request that caused the I/O error is ignored.

Corrective Action: Correct the problem in the file. Retry.

IOA194E mediaName - DEVICE deviceId - UNABLE TO OPEN FILE dsn

Explanation: The deviceId IOA Archive Server device could not open the dsn file.

The request is ignored.

Corrective Action: Verify that the dsn file exists and can be accessed.

IOA195I mediaName - DEVICE deviceId - PLEASE MOUNT REQUIRED VOLUME, OR ANSWER NO

Explanation: This information message indicates that a request was issued to mount a tape volume on the deviceId device, and that the requested tape volume was not mounted. The previous tape mount message was issued after an attempt to open a file on a tape volume that was not mounted on the device.

If this WTOR is answered NO, the mount request is canceled and the user request is ignored.

Corrective Action: If the requested volume cannot be mounted, or to cancel the mount request for any reason, reply NO to this WTOR. Otherwise, mount the requested volume.

IOA1A0I mediaName - NUMBER OF DEVICES = num1 NUMBER OF ACTIVE DEVICES = num2

Explanation: This information message is sent by the IOA Archive Server to the console in response to a DISPLAY command to indicate the following:

This message is preceded by message IOA1A1I or DSP1A1I, which supplies the IOA Archive Server name and media name for which the DISPLAY message was issued.

Corrective Action: No action is required.

IOA1A1I srvr - MEDIA mediaName STATUS DISPLAY:

Explanation: This information message is sent by the IOA Archive Server to the console in response to a DISPLAY command. This message is the header for messages that provide information about the status of mediaName media.

Corrective Action: No action is required.

IOA1A2I mediaName - MEDIA TYPE = media_type SYSTEM UNIT NAME = name

Explanation: This information message is sent by the IOA Archive Server to the console in response to a DISPLAY command. This message identifies the media type and system unit name defined in the IOASPRM member in the IOA Archive Server Installation Parameters.

Corrective Action: No action is required.

IOA1A3I mediaName - STATUS = status

Explanation: This information message is sent by the IOA Archive Server to the console in response to a DISPLAY command to provide information about the current status of media mediaName.

Corrective Action: No action is required.

IOA1A4I mediaName - NUMBER OF PENDING REQUESTS = num

Explanation: This information message is sent by the IOA Archive Server to the console in response to a DISPLAY command to provide information about the number of pending requests for mediaName media.

Corrective Action: No action is required.

IOA1A5I mediaName - DEVICE STATUS PLATTER VOLSER DSN

Explanation: This information message is sent by the IOA Archive Server to the console in response to a DISPLAY command. It is the header for IOA1A6I or DSP1A6I messages, which provide information about the status of each device assigned to media mediaName.

Corrective Action: No action is required.

IOA1A6I mediaName - device status platter volser dsn

Explanation: This information message is sent by the IOA Archive Server to the console in response to a DISPLAY command. Each message describes a device assigned to mediaName media.

This message follows message IOA1A5I or DSP1A5I, which provides the header for each field.

The variables in this message are:

Corrective Action: No action is required.

IOA1A7I mediaName - DEVICE USE STATUS VOLSER DSN

Explanation: This information message is sent by the IOA Archive Server to the console in response to a DISPLAY command. It is the header for IOA1A8I or DSP1A8I messages, which provide information about the status of each device assigned to mediaName media.

Corrective Action: No action is required.

IOA1A8I mediaName - device use status userId volser dsn

Explanation: This information message is sent by the IOA Archive server to the console in response to a DISPLAY command. It follows message IOA1A7I, which provides the header for each field. Each occurrence of this message describes a device assigned to mediaName media.

The variables in this message are:

Note:

The userId, vol, and dsn fields contain values only when the device is active.

Corrective Action: No action is required.

IOA1A9I mediaName - DEVICE STATUS USER-ID DSN

Explanation: This information message is sent by the IOA Archive Server to the console in response to a DISPLAY command. This message is the header for message IOA1AAI, which provides information about the status of each device assigned to the media identified in the message.

Corrective Action: No action is required.

IOA1AAI mediaName - deviceStatus userId dsn

Explanation: This information message is sent by the IOA Archive Server to the console in response to a DISPLAY command.

Each message provides information about a device assigned to the mediaName media. A message is issued for each device defined in the MAXCONN parameter in IOASPRM. These messages are preceded by message IOA1A9I, which provides the header for each field.

Possible values of deviceStatus are:

deviceStatus

Meaning

INACTIVE

The device is not yet activated.

ACTIVE

The device is retrieving data requested by the userId user from the dsn data set.

IDLE

The device is ACTIVE, but currently not working on any request.

Corrective Action: No action is required.

IOA1AEI mediaName - TVL: OWNER-ID deviceStatus, NUM OF REQUESTS - num DSN dsn

Explanation: This information message is sent by the IOA Archive Server to the console in response to a DISPLAY command to provide information about the current status of media mediaName.

Corrective Action: No action is required.

Parent Topic

IOA messages