This group includes messages for the Control-D, Control-D/Image, and Control-D/Page on Demand products.
Explanation: This information message indicates that a foreign report was successfully restored as a Control-D report.
Corrective Action: No action is required.
Explanation: The CTDFOR utility failed to restore the foreign report file.
The CTDFOR utility terminates. The foreign report is not restored.
Corrective Action: Examine other messages to determine the cause of the failure. Fix the problem, and rerun the CTDFOR utility.
Explanation: The parm parameter must be specified for the CTDFOR utility.
The CTDFOR utility terminates.
Corrective Action: Add the missing parm parameter, and rerun the CTDFOR utility.
Explanation: An invalid parameter (parm) was provided to the CTDFOR utility.
The CTDFOR utility terminates.
Corrective Action: Fix the invalid parm parameter, and rerun the CTDFOR utility.
Explanation: The same parameter (parm) was specified twice for the CTDFOR utility.
The CTDFOR utility terminates.
Corrective Action: Remove the redundant parm parameter, and rerun the CTDFOR utility.
Explanation: The date value (dateVal) specified in the REPDATE input parameter is a non-numeric value.
The CTDFOR utility terminates.
Corrective Action: Correct the invalid value in the REPDATE input parameter and rerun the utility.
Explanation: An invalid parameter was specified for the CTDFOR utility. The parameter name, parameter content, or parameter syntax is invalid.
The CTDFOR utility is terminated.
Corrective Action: Fix the parameters following the SYSIN DD statement, and rerun the CTDFOR utility.
Explanation: The CTDFOR utility tried to add a sysdata to the Active User Report List file (ACTUSR) but the sysdata already exists. The sysdata probably exists because the utility was previously run with the same input data.
The CTDFOR utility continues processing.
Corrective Action: No action is required.
Explanation: The CTDFOR utility tried to add a user record to the Active User Report List file (ACTUSR) but the record already exists. The user record probably exists because the utility was previously run with the same input data.
The CTDFOR utility continues processing.
Corrective Action: No action is required.
Explanation: This information message displays the input parameters provided by the user for the CTDFOR utility.
Corrective Action: No action is required.
Explanation: A product name specified in the parm PRODUCT parameter is unknown to the CTDFOR utility. It is not the name of a product supported by the utility.
The CTDFOR utility terminates.
Corrective Action: Set the PRODUCT parameter to the name of a supported product.
Explanation: The conversion routine called by the CTDFOR utility failed to convert the report file to a CDAM file.
The CTDFOR utility terminates.
Corrective Action: Examine other messages to determine the cause for the conversion routine failure. Correct the problem and rerun the CTDFOR utility.
Parent Topic |